<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object</link><pubDate>Fri, 12 Nov 2021 13:02:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Current Revision posted to Hevacomp Wiki by Shane Regan on 11/12/2021 1:02:51 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" rel="noopener noreferrer" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;Update your software to the &lt;a href="/products/building/performance/w/building_performance__wiki/15100/downloading-bentley-hevacomp-v8i-v26"&gt;latest version.&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/25</link><pubDate>Fri, 16 Nov 2018 14:07:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 25 posted to Hevacomp Wiki by Duncan Brown on 11/16/2018 2:07:48 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" rel="noopener noreferrer" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;Update your software to the &lt;a href="/products/building/performance/w/building_performance__wiki/23368/how-do-i-download-and-install-the-latest-update" rel="noopener noreferrer" target="_blank"&gt;latest version&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/24</link><pubDate>Fri, 03 Aug 2018 15:40:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 24 posted to Hevacomp Wiki by Duncan Brown on 8/3/2018 3:40:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" rel="noopener noreferrer" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="color:#000000;"&gt;&lt;strong&gt;We strongly recommend applying &lt;a title="How to download and install the latest update" href="/products/building/performance/w/building_performance__wiki/23368.how-do-i-download-and-install-the-latest-update" rel="noopener noreferrer" target="_blank"&gt;&lt;span style="color:#000000;"&gt;the&lt;/span&gt;&lt;/a&gt; latest update before following these methods.&lt;/strong&gt; If that fails to resolve the issue, then the&amp;nbsp;next best thing would be to replace &lt;/span&gt;the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sa5befd2016148db9" rel="noopener noreferrer" target="_blank"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/23</link><pubDate>Fri, 03 Aug 2018 15:39:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 23 posted to Hevacomp Wiki by Duncan Brown on 8/3/2018 3:39:49 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" rel="noopener noreferrer" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="color:#000000;"&gt;&lt;strong&gt;We strongly recommend applying &lt;a title="How to download and install the latest update" href="/products/building/performance/w/building_performance__wiki/23368.how-do-i-download-and-install-the-latest-update" rel="noopener noreferrer" target="_blank"&gt;&lt;span style="color:#000000;"&gt;the&lt;/span&gt;&lt;/a&gt; latest update before following these methods.&lt;/strong&gt; If that fails to resolve the issue, then the&amp;nbsp;next best thing would be to replace &lt;/span&gt;the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sa5befd2016148db9"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/22</link><pubDate>Wed, 01 Aug 2018 12:45:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 22 posted to Hevacomp Wiki by Duncan Brown on 8/1/2018 12:45:26 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" rel="noopener noreferrer" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="color:#000000;"&gt;&lt;strong&gt;We strongly recommend applying &lt;a title="How to download and install the latest update" href="/products/building/performance/w/building_performance__wiki/23368.how-do-i-download-and-install-the-latest-update" rel="noopener noreferrer" target="_blank"&gt;&lt;span style="color:#000000;"&gt;the&lt;/span&gt;&lt;/a&gt; latest update before following these methods.&lt;/strong&gt; If that fails to resolve the issue, then the&amp;nbsp;next best thing would be to replace &lt;/span&gt;the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sf22e1a8778e48139"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/21</link><pubDate>Wed, 08 Mar 2017 12:05:23 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 21 posted to Hevacomp Wiki by Duncan Brown on 3/8/2017 12:05:23 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="color:#000000;"&gt;&lt;strong&gt;We strongly recommend applying &lt;a title="How to download and install the latest update" href="/products/building/performance/w/building_performance__wiki/23368.how-do-i-download-and-install-the-latest-update" target="_blank"&gt;&lt;span style="color:#000000;"&gt;Update 5&lt;/span&gt;&lt;/a&gt; before following these methods.&lt;/strong&gt; If that fails to resolve the issue, then the&amp;nbsp;next best thing would be to replace &lt;/span&gt;the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sf22e1a8778e48139"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/20</link><pubDate>Wed, 08 Mar 2017 12:04:00 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 20 posted to Hevacomp Wiki by Duncan Brown on 3/8/2017 12:04:00 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:left;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="color:#000000;"&gt;&lt;strong&gt;We strongly recommend applying &lt;a title="How to download and install the latest update" href="/products/building/performance/w/building_performance__wiki/23368.how-do-i-download-and-install-the-latest-update" target="_blank"&gt;&lt;span style="color:#000000;"&gt;Update 5&lt;/span&gt;&lt;/a&gt; before following these methods.&lt;/strong&gt; If that fails to resolve the issue, then the&amp;nbsp;&lt;/span&gt;quickest way to resolve this is to replace the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sf22e1a8778e48139"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/19</link><pubDate>Wed, 25 Jan 2017 12:45:21 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 19 posted to Hevacomp Wiki by Duncan Brown on 1/25/2017 12:45:21 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The quickest way to resolve this is to replace the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sf22e1a8778e48139"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/18</link><pubDate>Thu, 12 Jan 2017 11:19:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 18 posted to Hevacomp Wiki by Duncan Brown on 1/12/2017 11:19:46 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;You should not need to re-install the software to resolve this issue&lt;br /&gt;&amp;nbsp;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off&lt;br /&gt;&amp;nbsp;&lt;/span&gt;&lt;span style="color:#1e90ff;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;&lt;span style="color:#1e90ff;"&gt;An administrator password may be required to complete these methods&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The quickest way to resolve this is to replace the new HevBanner.Exe (the Bentley Hevacomp launch program) with the previous version. This will not result in any loss of functionality other than RSS feeds, and if you would like to see that information, you can subscribe to the &lt;a title="Hevacomp Communities" href="/products/building/performance/"&gt;Hevacomp Communities page&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;To use the previous launcher program:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;1] Download the replacement file &lt;a title="Hevacomp Launcher" href="https://bentley.sharefile.com/d-sf22e1a8778e48139"&gt;from here&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;2] Using Windows Explorer, navigate into the installation folder for Bentley Hevacomp. This is usually:&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;3] Unzip the file you downloaded in step 1] directly into this folder. When asked to overwrite the existing file, select yes.&lt;/p&gt;
&lt;p&gt;You should now be able to launch your software.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/17</link><pubDate>Thu, 05 Jan 2017 08:48:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 17 posted to Hevacomp Wiki by Shane Regan on 1/5/2017 8:48:24 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;You should not need to re-install the software to resolve this issue&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;&lt;span style="color:#800000;"&gt;&lt;span style="color:#1e90ff;"&gt;An administrator password may be required to complete these methods&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s70ce918abdd4c94a" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/16</link><pubDate>Wed, 23 Nov 2016 11:52:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 16 posted to Hevacomp Wiki by Shane Regan on 11/23/2016 11:52:47 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;You should not need to re-install the software to resolve this issue&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;&lt;span style="color:#800000;"&gt;&lt;span style="color:#1e90ff;"&gt;An administrator password may be required to complete these methods&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s81482b43d0144fc8" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/15</link><pubDate>Wed, 16 Nov 2016 10:34:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 15 posted to Hevacomp Wiki by Shane Regan on 11/16/2016 10:34:06 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces either of the following errors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7178.Capture1.PNG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;You should not need to re-install the software to resolve this issue&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;&lt;span style="color:#800000;"&gt;&lt;span style="color:#1e90ff;"&gt;An administrator password may be required to complete these methods&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-sf6ff94c85fe40319" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create, -2147024893 (80070003)&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/14</link><pubDate>Tue, 08 Nov 2016 16:26:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 14 posted to Hevacomp Wiki by Duncan Brown on 11/8/2016 4:26:29 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;You should not need to re-install the software to resolve this issue&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;&lt;span style="color:#800000;"&gt;&lt;span style="color:#1e90ff;"&gt;An administrator password may be required to complete these methods&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-sf6ff94c85fe40319" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp Mechanical and Electrical Designer, error, activex cannot create&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/13</link><pubDate>Tue, 18 Oct 2016 13:22:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 13 posted to Hevacomp Wiki by Shane Regan on 10/18/2016 1:22:44 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;You should not need to re-install the software to resolve this issue.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;An administrator password may be required to complete these methods.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-sf6ff94c85fe40319" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Run time Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/12</link><pubDate>Tue, 27 Sep 2016 15:26:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 12 posted to Hevacomp Wiki by Duncan Brown on 9/27/2016 3:26:14 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;You should not need to re-install the software to resolve this issue.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;An administrator password may be required to complete these methods.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s0e515138cc24276b" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Runtime Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/11</link><pubDate>Thu, 15 Sep 2016 11:04:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 11 posted to Hevacomp Wiki by Duncan Brown on 9/15/2016 11:04:11 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You should not need to re-install the software to resolve this issue.&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;These methods should be completed on the user&amp;#39;s Windows log in and UAC must be turned off.&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;If you have multiple user log in&amp;#39;s on a computer, then you may need to run this process for each user.&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;An administrator password may be required to complete these methods.&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in to the users account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s0e515138cc24276b" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator. If prompted, enter the administrator password.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Runtime Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/10</link><pubDate>Thu, 15 Sep 2016 10:50:57 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 10 posted to Hevacomp Wiki by Duncan Brown on 9/15/2016 10:50:57 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;strong&gt;Disambiguation&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;If you receive a run time error 429 &lt;strong&gt;&lt;em&gt;without&lt;/em&gt;&lt;/strong&gt; this associate screen corruption then please see &lt;a title="Alternative 429 solution" href="/products/building/performance/w/building_performance__wiki/8753.run-time-error-429-or-unexpected-error-quitting-message" target="_blank"&gt;this document&lt;/a&gt; instead.&lt;/p&gt;
&lt;/td&gt;
&lt;td align="center" valign="middle"&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2476.RSS_2D00_SMALL.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You do not need to re-install the software to resolve this issue.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;These methods must be completed with a local administrator account and UAC &lt;span style="text-decoration:underline;"&gt;&lt;em&gt;must be turned off&lt;/em&gt;&lt;/span&gt;.&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You may need the assistance of your IT department with this.&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in with a local administrator account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s0e515138cc24276b" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Runtime Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/9</link><pubDate>Fri, 09 Sep 2016 09:31:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 9 posted to Hevacomp Wiki by Duncan Brown on 9/9/2016 9:31:48 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You do not need to re-install the software to resolve this issue.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;These methods must be completed with a local administrator account and UAC &lt;span style="text-decoration:underline;"&gt;&lt;em&gt;must be turned off&lt;/em&gt;&lt;/span&gt;.&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You may need the assistance of your IT department with this.&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Ensure you have are logged in with a local administrator account and &lt;a title="How to turn off UAC" href="https://technet.microsoft.com/en-us/library/cc709691(v=ws.10).aspx" target="_blank"&gt;UAC has been turned off&lt;/a&gt;. Turning off UAC may&amp;nbsp;require a reboot.&lt;/p&gt;
&lt;p&gt;2] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s0e515138cc24276b" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;3] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&lt;br /&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Runtime Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/8</link><pubDate>Thu, 08 Sep 2016 13:42:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 8 posted to Hevacomp Wiki by Duncan Brown on 9/8/2016 1:42:31 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You do not need to re-install the software to resolve this issue&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Download this small&amp;nbsp;&lt;a title="Download the RSS fix" href="https://bentley.sharefile.com/d-s0e515138cc24276b" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;2] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&amp;nbsp;&lt;br /&gt;3] Ensure UAC is turned off. This may require the computer to be rebooted.&lt;/p&gt;
&lt;p&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;These methods must be completed using an administrator account. &lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You may wish to consult your IT if this is not available.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Runtime Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/7</link><pubDate>Thu, 08 Sep 2016 12:29:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 7 posted to Hevacomp Wiki by Shane Regan on 9/8/2016 12:29:08 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You do not need to re-install the software to resolve this issue&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Download this small&amp;nbsp;&lt;a href="https://bentley.sharefile.com/d-s0e515138cc24276b"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;2] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&amp;nbsp;&lt;br /&gt;3] Ensure UAC is turned off. This may require the computer to be rebooted.&lt;/p&gt;
&lt;p&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;These methods must be completed using an administrator account. &lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You may wish to consult your IT if this is not available.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;
</description></item><item><title>Runtime Error 429:  ActiveX component can't create object</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object/revision/6</link><pubDate>Thu, 08 Sep 2016 11:19:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0d9c97fd-2958-4c15-8891-21f7886d58d5</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/30621/run-time-error-429-activex-component-can-t-create-object#comments</comments><description>Revision 6 posted to Hevacomp Wiki by Duncan Brown on 9/8/2016 11:19:47 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical and Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (26.xx.xx.xx)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;Following a new installation, attempting to run Hevacomp produces the following error:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_07_5F00_15_2D00_19_2D00_01.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;This is usually due to a lack of permissions during the installation process, which blocks registration of the RSS feed components.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You do not need to re-install the software to resolve this issue&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;1] Download this small &lt;a title="RSS component registration" href="https://bentley.sharefile.com/d-s5c31ee468de42208" target="_blank"&gt;zip file&lt;/a&gt;&amp;nbsp;- this contains a batch file and components to help register the RSS feed&lt;/p&gt;
&lt;p&gt;2] Extract the contents of the zip file into your installation folder.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 32bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;For 64bit Windows this is likely to be:&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:90px;"&gt;&lt;span style="font-family:courier new,courier;"&gt;C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Once extracted you should see:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_11_2D00_57_2D00_43.jpg" /&gt;&lt;/a&gt;&amp;nbsp;&lt;br /&gt;3] Ensure UAC is turned off. This may require the computer to be rebooted.&lt;/p&gt;
&lt;p&gt;4] Right click on&amp;nbsp;&lt;span style="font-family:courier new,courier;"&gt;REGRSS.BAT&lt;/span&gt; and choose Run as Administrator.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/2016_2D00_09_2D00_08_5F00_12_2D00_01_2D00_41.jpg" /&gt;&lt;/a&gt;5] A command window should appear, confirming registration.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/cmd-prompt.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;These methods must be completed using an administrator account. &lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;You may wish to consult your IT if this is not available.&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: installation, 429, Hevacomp, ActiveX&lt;/div&gt;