<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Heat Loss Calculation - Showing Preheat Times</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31321/heat-loss-calculation-showing-preheat-times</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Heat Loss Calculation - Showing Preheat Times</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31321/heat-loss-calculation-showing-preheat-times</link><pubDate>Mon, 24 Oct 2016 11:11:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:13c7d648-6dca-42c2-9545-1cecda8b9887</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31321/heat-loss-calculation-showing-preheat-times#comments</comments><description>Current Revision posted to Hevacomp Wiki by Duncan Brown on 10/24/2016 11:11:31 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Design&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;You can view the effect of plant margins on pre-heat times within the Heat Loss Calculation&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To view the various calculated preheat and plant margin time select&amp;nbsp;the &amp;#39;yes&amp;#39; option for the question&amp;nbsp;&amp;quot;Show Intermittent Heating and pre-heat times&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/PreHeat.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/PreHeat.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A note on the calculation method (from the Heat Loss manual)&lt;/p&gt;
&lt;h2 style="margin:0in 0in 0pt;text-align:justify;"&gt;Intermittent operation&lt;/h2&gt;
&lt;p style="text-align:justify;"&gt;The operation of the plant under intermittent conditions is considered, using the equations in CIBSE Guide A.5.&amp;nbsp; The building response factor (fr) is computed from the building U values, admittances and infiltration, this is used to compute the intermittent plant factor (F3):&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;F3 = 1 + 1.2 (24 - n) (fr - 1) / (24 + n (fr-1))&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&amp;nbsp;where&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;n = occupancy&amp;nbsp;hours + preheat&amp;nbsp;hours.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;A table of plant preheat&amp;nbsp;periods at various plant ratios is displayed, this enables preheating regimes to be examined.&amp;nbsp;It will be found that the longer the preheat&amp;nbsp;period, the lower the installed plant capacity.&amp;nbsp; A plant capacity can be selected from the table to give the required balance between plant cost (low plant capacity) and fuel efficiency (short preheat periods).&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: output, Hevacomp Mechanical Designer, plant ratio, loss, Heat loss, pre-heat&lt;/div&gt;
</description></item><item><title>Heat Loss Calculation - Showing Preheat Times</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31321/heat-loss-calculation-showing-preheat-times/revision/1</link><pubDate>Thu, 20 Oct 2016 11:44:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:13c7d648-6dca-42c2-9545-1cecda8b9887</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31321/heat-loss-calculation-showing-preheat-times#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 10/20/2016 11:44:43 AM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Design&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;You can view the effect of plant margins on pre-heat times within the Heat Loss Calculation&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To view the various calculated preheat and plant margin time select&amp;nbsp;the &amp;#39;yes&amp;#39; option for the question&amp;nbsp;&amp;quot;Show Intermittent Heating and pre-heat times&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/PreHeat.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/PreHeat.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A note on the calculation method (from the Heat Loss manual)&lt;/p&gt;
&lt;h2 style="margin:0in 0in 0pt;text-align:justify;"&gt;Intermittent operation&lt;/h2&gt;
&lt;p style="text-align:justify;"&gt;The operation of the plant under intermittent conditions is considered, using the equations in CIBSE Guide A.5.&amp;nbsp; The building response factor (fr) is computed from the building U values, admittances and infiltration, this is used to compute the intermittent plant factor (F3):&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;F3 = 1 + 1.2 (24 - n) (fr - 1) / (24 + n (fr-1))&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&amp;nbsp;where&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;n = occupancy&amp;nbsp;hours + preheat&amp;nbsp;hours.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;A table of plant preheat&amp;nbsp;periods at various plant ratios is displayed, this enables preheating regimes to be examined.&amp;nbsp;It will be found that the longer the preheat&amp;nbsp;period, the lower the installed plant capacity.&amp;nbsp; A plant capacity can be selected from the table to give the required balance between plant cost (low plant capacity) and fuel efficiency (short preheat periods).&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: output, Hevacomp Mechanical Designer, plant ratio, loss, Heat loss, pre-heat&lt;/div&gt;