<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>CHP will not connect to an HWS sysytem</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>CHP will not connect to an HWS sysytem</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem</link><pubDate>Mon, 24 Aug 2020 09:13:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cf5da964-2fa0-4617-8e4b-67a09ad482e7</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem#comments</comments><description>Current Revision posted to Hevacomp Wiki by Shane Regan on 8/24/2020 9:13:51 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;CHP cannot be directly and solely connected to&amp;nbsp;HWS.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;At this time, you cannot specify a CHP solely for HWS generation. &lt;br /&gt;&lt;br /&gt;a CHP system can only be attached to the Generator of a HVAC system. To take advantage of CHP for HWS generation, your HWS generator must be the same as the HVAC system (i.e. &amp;quot;Same as zone x heat source&amp;quot;). From the iSBEM modeling guide:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/chp.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/chp.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A possible work around for this limitation&amp;nbsp;would be to create a new&amp;nbsp;&amp;#39;empty&amp;#39; zone in the project. Set up the&amp;nbsp;empty zone (Room) with a very small volume and no occupants. You can specify a separate heating system for the zone, attach a CHP system to the heating system set to 0% Heating Supplied, 100% Water Supplied and then create you HWS system so it is powered by your empty zones heat source.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: HWS, SBEM, Hevacomp Mechanical Designer, PartL, CHP&lt;/div&gt;
</description></item><item><title>CHP will not connect to an HWS sysytem</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem/revision/4</link><pubDate>Tue, 23 May 2017 11:51:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cf5da964-2fa0-4617-8e4b-67a09ad482e7</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Duncan Brown on 5/23/2017 11:51:08 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;CHP cannot be directly and solely connected to&amp;nbsp;HWS.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;At this time, you cannot specify a CHP solely for HWS generation. &lt;br /&gt;&lt;br /&gt;a CHP system can only be attached to the Generator of a HVAC system. To take advantage of CHP for HWS generation, your HWS generator must be the same as the HVAC system (i.e. &amp;quot;Same as zone x heat source&amp;quot;). From the iSBEM modeling guide:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/chp.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/chp.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A possible work around for this limitation&amp;nbsp;would be to create a new&amp;nbsp;&amp;#39;empty&amp;#39; zone in the project. Set up the&amp;nbsp;empty zone (Room) with a very small volume and no occupants. You can specify a separate heating system for the zone, attach a CHP system to the heating system set to 0% Heating Supplied, 100% Water Supplied and then create you HWS system so it is powered by your empty zones heat source.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: HWS, SBEM, Hevacomp Mechanical Designer, PartL, CHP&lt;/div&gt;
</description></item><item><title>CHP will not connect to an HWS sysytem</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem/revision/3</link><pubDate>Tue, 28 Mar 2017 11:47:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cf5da964-2fa0-4617-8e4b-67a09ad482e7</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Duncan Brown on 3/28/2017 11:47:31 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;CHP cannot be directly and solely connected to&amp;nbsp;HWS.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;At this time, you cannot specify a CHP solely for HWS generation. &lt;br /&gt;&lt;br /&gt;a CHP system can only be attached to the Generator of a HVAC system. To take advantage of CHP for HWS generation, your HWS generator must be the same as the HVAC system (i.e. &amp;quot;Same as zone x heat source&amp;quot;).&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;From the iSBEM modeling guide:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/CHP_2500_20Constraints.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/CHP_2500_20Constraints.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;A possible work around for this limitation&amp;nbsp;would be to create a new&amp;nbsp;&amp;#39;empty&amp;#39; zone in the project. Set up the&amp;nbsp;empty zone (Room) with a very small volume and no occupants. You can specify a separate heating system for the zone, attach a CHP system to the heating system set to 0% Heating Supplied, 100% Water Supplied and then create you HWS system so it is powered by your empty zones heat source.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: HWS, SBEM, Hevacomp Mechanical Designer, PartL, CHP&lt;/div&gt;
</description></item><item><title>CHP will not connect to an HWS sysytem</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem/revision/2</link><pubDate>Wed, 16 Nov 2016 15:31:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cf5da964-2fa0-4617-8e4b-67a09ad482e7</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Duncan Brown on 11/16/2016 3:31:39 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;CHP cannot be directly and solely connected to&amp;nbsp;HWS.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;At this time, you cannot specify a CHP solely for HWS generation. &lt;br /&gt;&lt;br /&gt;a CHP system can only be attached to the Generator of a HVAC system. To take advantage of CHP for HWS generation, your HWS generator must be the same as the HVAC system (i.e. &amp;quot;Same as zone x heat source&amp;quot;).&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;From the iSBEM modeling guide:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/CHP_2500_20Constraints.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/CHP_2500_20Constraints.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;A possible work around for this limitation&amp;nbsp;would be to create a new&amp;nbsp;&amp;#39;empty&amp;#39; zone in the project. Set up the&amp;nbsp;empty zone (Room) with a very small volume and no occupants. You can specify a separate heating system for the zone, attach a CHP system to the heating system set to 0% Heating Supplied, 100% Water Supplied and then create you HWS system so it is powered by your empty zones heat source.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: HWS, SBEM, Hevacomp Mechanical Designer, PartL, CHP&lt;/div&gt;
</description></item><item><title>CHP will not connect to an HWS sysytem</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem/revision/1</link><pubDate>Wed, 02 Nov 2016 15:23:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:cf5da964-2fa0-4617-8e4b-67a09ad482e7</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/31493/chp-will-not-connect-to-an-hws-sysytem#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 11/2/2016 3:23:39 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Hevacomp&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;CHP cannot be directly and solely connected to&amp;nbsp;HWS.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;At this time, you cannot specify a CHP solely for HWS generation. &lt;br /&gt;&lt;br /&gt;a CHP system can only be attached to the Generator of a HVAC system. To take advantage of CHP for HWS generation, your HWS generator must be the same as the HVAC system (i.e. &amp;quot;Same as zone x heat source&amp;quot;).&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;From the iSBEM modeling guide:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/CHP_2500_20Constraints.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/CHP_2500_20Constraints.jpg" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;A possible work around for this limitation&amp;nbsp;would be to create a new&amp;nbsp;&amp;#39;empty&amp;#39; zone in the project. Set up the&amp;nbsp;empty zone (Room) with a very small volume and no occupants. You can specify a separate heating system for the zone, attach a CHP system to the heating system set to 0% Heating Supplied, 100% Water Supplied and then create you HWS system so it is powered by your empty zones heat source.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: HWS, SBEM, Hevacomp Mechanical Designer, PartL, CHP&lt;/div&gt;