Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • More
  • Cancel
Hevacomp
Hevacomp Wiki Compliance report is not generating - option is 'greyed out'
    • Sign in
    • +Hevacomp General Information
    • +Hevacomp Dynamic Simulation
    • +Hevacomp Electrical Designer
    • -Hevacomp Mechanical Designer
      • +Design Database - Hevacomp Mechanical Designer
      • +Mechanical Design - Hevacomp Mechanical Designer
      • +Netsys - Hevacomp Mechanical Designer
      • -PartL - Hevacomp Mechanical Designer
        • Actual Emission Rate (BER) displayed as zero
        • Alpha Values and Thermal Bridging
        • An important note on the PartL calculation
        • Auxiliary Energy - an explanation
        • BRUKL and ENE01 Compliance Checker differences
        • BRUKL Compliance Report Project Name
        • Calculating hot water demand
        • Cannot lodge XML - Insurer details are missing
        • Cannot select Display Lighting
        • CHP will not connect to an HWS sysytem
        • Compliance report is not generating - option is 'greyed out'
        • Consideration of shading factors
        • Considering ground floor U-values
        • Defining air permeability
        • Defining Door Types
        • Defining solar collectors
        • District heating is displayed in BRUKL report, none selected
        • Energy Consumption on BRUKL report
        • Entering non-standard HVAC systems
        • EPBD Recast - Specifying alternative forms of energy
        • EPC and Recommendations menus
        • EPCGEN Error, no compliance report and blank results
        • EPCgen.net Activation Code
        • Excessive thermal bridging
        • External doors missing from BRUKL report
        • Fuel Heating Type
        • General Lighting output in compliance report
        • Glazing area differences
        • Glazing Light Transmittance in Part L Results
        • Heating System Controls greyed out
        • Inputting DHW Generator Seasonal Efficiency
        • Inputting SFP for fan coils
        • Internal Surfaces appearing in PartL U-Value checks
        • Keyword out of range: Heat SSEFF error
        • Lighting results do not match input data
        • Notional Auxiliary Energy requirements increase when using HEPA filters
        • Occupancy gains may appear different
        • Omitted Recommendations shown in Recommendations Report
        • Partition Centre Lines
        • PartL 2010 and 2013 in the same project
        • Potential Measures for Scottish EPC's
        • Power Factor and Lighting Controls
        • Project data changing after loading project into different software versions
        • Renewable fuel sources
        • Result changes between 2006, 2010 and 2013 regulations
        • Room Types and the NCM Database
        • Shell and Core Building Services can cause an error
        • The BRUKL document is listing an unexpected building type
        • The NCM modelling guide
        • Thermal Bridging/PSI values
        • Usage of Biofuels
        • U-value check in Compliance Report
        • U-Value checks not carried out
        • XML document is not produced
      • +System Builder - Hevacomp Mechanical Design
    • +Installation and activation
    • +Troubleshooting
    • +Windows tips and tricks
    • Working From Home with Hevacomp

     
     Questions about this article, topic, or product? Click here. 

    Compliance report is not generating - option is 'greyed out'

      Product(s): Hevacomp Mechanical Designer
      Version(s): V8i
      Environment: N/A
      Area: Design Database
      Subarea: Part L

    Overview

    In some very rare instances the PartL program will not produce a Compliance Report, and the Compliance Report radio button is greyed out. Other reports - including the Energy Report are produced.

     Method

    First of all you should check if the project can be calculated successfully on a colleagues computer. If this calculates succesfully then this may point to an issue with your installation. Load the project on your computer again and run the calculation. Once run, open the project folder and look for a file called

    SBEM.LOG

    Open this file with Notepad and look towards the bottom of the page and see if there is an "Error Loading BRUKL.DLL" message (as indicated here) - if this message exists then you should follow these guidelines and perform a clean installation of the software. Ensure you follow all of the steps.

    • greyed out
    • Hevacomp Mechanical Designer
    • Compliance Report
    • PartL
    • Share
    • History
    • More
    • Cancel
    • Duncan Brown Created by Duncan Brown
    • When: Thu, Feb 16 2017 6:06 AM
    • Shane Regan Last revision by Bentley Colleague Shane Regan
    • When: Mon, Aug 24 2020 5:13 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2022 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies