<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Cable sizing - Cable is undersized?</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/33020/cable-sizing---cable-is-undersized</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Cable sizing - Cable is undersized?</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/33020/cable-sizing---cable-is-undersized</link><pubDate>Thu, 27 Jul 2017 10:47:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9ea466f5-a650-4944-9056-b4261ddb5ef8</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/33020/cable-sizing---cable-is-undersized#comments</comments><description>Current Revision posted to Hevacomp Wiki by Duncan Brown on 7/27/2017 10:47:28 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp&amp;nbsp;Electrical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;It may appear on occasion that a&amp;nbsp;conductor is undersized. The methods used for cable sizing are described below.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Bentley Hevacomp Connect program has a number of considerations when sizing phase conductors.&lt;/p&gt;
&lt;p&gt;Where:&lt;/p&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:center;" width="15%"&gt;&lt;strong&gt;Ib&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;circuit current&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;In&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;nominal device rating&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;It&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;required current for circuit&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Ca&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for ambient temperatures (Tables 4B1 and 4B2)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Cg&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for grouping (Tables 4C1, 4C2, 4C3, 4C4 and 4C5)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Ci&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for insulation (specified with circuit data)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Cd&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction factor for BS3036 fuses (=.0725)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Cc&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for buried cable (= 0.9)&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;For fixed power, radial, lighting and sub main circuits:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It = ln / Ca / Cg / Ci / Cd / Cc&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Where grouping is considered, if the group is not liable to simultaneous overload, then the higher of the following two values for required current is taken:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It1 = Ib / Ca / Cg / Ci / Cd / Cc&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It2 = 1 / CA / Ci / sqr ( In x In / Cd / Cd / Cc / Cc + 0.48 x Ib x Ib (( 1 - Cg x Cg ) / Cg /Cg ))&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;(Please see BS 7671: 2015, Appendix 4, Section 5 for more information)&lt;/p&gt;
&lt;p&gt;For ring circuits, &lt;strong&gt;In&lt;/strong&gt; is replaced by 20 Amp rating, &lt;strong&gt;Ib &lt;/strong&gt;is replaced by 20 Amps.&lt;/p&gt;
&lt;p&gt;For motor circuits, the following is used.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It = Ib / Ca / Cg / Ci / Cd / Cc&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;You should note that for motor circuits, the circuit current is used. This information is from &lt;em&gt;Practical Guide to the Wiring Regulations (Stokes) Section 7.3.2 - Protection against overload - motors&lt;/em&gt;:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/Star-Conductor.jpg"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Star-Conductor.jpg" /&gt;&lt;/a&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Cable sizing - Cable is undersized?</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/33020/cable-sizing---cable-is-undersized/revision/1</link><pubDate>Mon, 27 Feb 2017 15:43:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9ea466f5-a650-4944-9056-b4261ddb5ef8</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/33020/cable-sizing---cable-is-undersized#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 2/27/2017 3:43:03 PM&lt;br /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;It may appear on occasion that a&amp;nbsp;conductor is undersized. The methods used for cable sizing are described below.&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Bentley Hevacomp Connect program has a number of considerations when sizing phase conductors.&lt;/p&gt;
&lt;p&gt;Where:&lt;/p&gt;
&lt;table style="width:100%;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td width="15%" style="text-align:center;"&gt;&lt;strong&gt;Ib&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;circuit current&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;In&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;nominal device rating&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;It&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;required current for circuit&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Ca&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for ambient temperatures (Tables 4B1 and 4B2)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Cg&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for grouping (Tables 4C1, 4C2, 4C3, 4C4 and 4C5)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Ci&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for insulation (specified with circuit data)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Cd&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction factor for BS3036 fuses (=.0725)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:center;"&gt;&lt;strong&gt;Cc&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Correction for buried cable (= 0.9)&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;For fixed power, radial, lighting and sub main circuits:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It = ln / Ca / Cg / Ci / Cd / Cc&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Where grouping is considered, if the group is not liable to simultaneous overload, then the higher of the following two values for required current is taken:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It1 = Ib / Ca / Cg / Ci / Cd / Cc&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It2 = 1 / CA / Ci / sqr ( In x In / Cd / Cd / Cc / Cc + 0.48 x Ib x Ib (( 1 - Cg x Cg ) / Cg /Cg ))&lt;/strong&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;(Please see BS 7671: 2015, Appendix 4, Section 5 for more information)&lt;/p&gt;
&lt;p&gt;For ring circuits, &lt;strong&gt;In&lt;/strong&gt; is replaced by 20 Amp rating, &lt;strong&gt;Ib &lt;/strong&gt;is replaced by 20 Amps.&lt;/p&gt;
&lt;p&gt;For motor circuits, the following is used.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;strong&gt;It = Ib / Ca / Cg / Ci / Cd / Cc&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;You should note that for motor circuits, the circuit current is used. This information is from &lt;em&gt;Practical Guide to the Wiring Regulations (Stokes) Section 7.3.2 - Protection against overload - motors&lt;/em&gt;:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/Star-Conductor.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Star-Conductor.jpg" alt=" " /&gt;&lt;/a&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;