Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
Hevacomp Wiki PartL 2010 and 2013 in the same project
    • Sign In
    • +Hevacomp General Information
    • +Hevacomp Dynamic Simulation
    • +Hevacomp Electrical Designer
    • -Hevacomp Mechanical Designer
      • +Design Database - Hevacomp Mechanical Designer
      • +Mechanical Design - Hevacomp Mechanical Designer
      • +Netsys - Hevacomp Mechanical Designer
      • -PartL - Hevacomp Mechanical Designer
        • Actual Emission Rate (BER) displayed as zero
        • Alpha Values and Thermal Bridging
        • An important note on the PartL calculation
        • Auxiliary Energy - an explanation
        • BRUKL and ENE01 Compliance Checker differences
        • BRUKL Compliance Report Project Name
        • Calculating hot water demand
        • Cannot lodge XML - Insurer details are missing
        • Cannot select Display Lighting
        • CHP will not connect to an HWS sysytem
        • Consideration of shading factors
        • Considering ground floor U-values
        • Defining air permeability
        • Defining Door Types
        • Defining solar collectors
        • District heating is displayed in BRUKL report, none selected
        • Energy Consumption on BRUKL report
        • Entering non-standard HVAC systems
        • EPBD Recast - Specifying alternative forms of energy
        • EPC and Recommendations menus
        • EPCGEN Error, no compliance report and blank results
        • EPCgen.net Activation Code
        • Excessive thermal bridging
        • External doors missing from BRUKL report
        • Fuel Heating Type
        • General Lighting output in compliance report
        • Glazing area differences
        • Glazing Light Transmittance in Part L Results
        • Heating System Controls greyed out
        • Inputting DHW Generator Seasonal Efficiency
        • Inputting SFP for fan coils
        • Internal Surfaces appearing in PartL U-Value checks
        • Keyword out of range: Heat SSEFF error
        • Lighting results do not match input data
        • Notional Auxiliary Energy requirements increase when using HEPA filters
        • Occupancy gains may appear different
        • Omitted Recommendations shown in Recommendations Report
        • Partition Centre Lines
        • Potential Measures for Scottish EPC's
        • Power Factor and Lighting Controls
        • Project data changing after loading project into different software versions
        • Renewable fuel sources
        • Room Types and the NCM Database
        • Shell and Core Building Services can cause an error
        • The BRUKL document is listing an unexpected building type
        • The NCM modelling guide
        • Thermal Bridging/PSI values
        • Usage of Biofuels
        • U-value check in Compliance Report
        • U-Value checks not carried out
        • XML document is not produced
      • +System Builder - Hevacomp Mechanical Design
    • +Installation and activation
    • +Troubleshooting
    • +Windows tips and tricks
    • Working From Home with Hevacomp

     
     Questions about this article, topic, or product? Click here. 

    PartL 2010 and 2013 in the same project

      Product(s): Hevacomp Mechanical Designer
      Version(s): V8i (N/A)
      Environment: N/A
      Area: N/A
      Subarea: N/A

    Problem

    Since the release of PartL 2010 v4.1.g and PartL 2013 v5.3.a, the PartL 2010 program has been moved from V25 Design Database into V26 Design Database. This allows the user to uninstall V25 software, unless they are producing Republic of Ireland EPC's

    As both PartL 2010 and PartL 2013 are now in the same program, the user may consider this as a potential comparison tool between the versions, but this should not be attempted. An existing V25 project should only be run in PartL 2010, V26. And any new V26 projects, should be run in PartL 2013. There should be no new PartL 2010 projects at this time.

    Solution

    The dataset for 2010 and 2013 Part L calculations are substantially different. So much so that once a PartL 2010 calculation is brought into the 2013 program, the project can only be used as a PartL 2013 calculation.

    Consideration should also be made that with the different datasets and calculations, comparison's are essentially useless.

    • Part L
    • Hevacomp Mechanical Designer
    • PartL
    • 2013
    • 2010
    • Share
    • History
    • More
    • Cancel
    • Duncan Brown Created by Duncan Brown
    • When: Tue, Dec 12 2017 6:18 AM
    • Shane Regan Last revision by Bentley Colleague Shane Regan
    • When: Thu, Sep 7 2023 5:52 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies