Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • More
  • Cancel
Hevacomp
Hevacomp Wiki Watermarks on SBEM output documents
    • Sign in
    • +Hevacomp General Information
    • +Hevacomp Dynamic Simulation
    • +Hevacomp Electrical Designer
    • -Hevacomp Mechanical Designer
      • +Design Database - Hevacomp Mechanical Designer
      • +Mechanical Design - Hevacomp Mechanical Designer
      • +Netsys - Hevacomp Mechanical Designer
      • -PartL - Hevacomp Mechanical Designer
        • Actual Emission Rate (BER) displayed as zero
        • Alpha Values and Thermal Bridging
        • An important note on the PartL calculation
        • Auxiliary Energy - an explanation
        • BRUKL and ENE01 Compliance Checker differences
        • BRUKL Compliance Report Project Name
        • Calculating hot water demand
        • Cannot lodge XML - Insurer details are missing
        • Cannot select Display Lighting
        • CHP will not connect to an HWS sysytem
        • Compliance report is not generating - option is 'greyed out'
        • Consideration of shading factors
        • Considering ground floor U-values
        • Defining air permeability
        • Defining Door Types
        • Defining solar collectors
        • District heating is displayed in BRUKL report, none selected
        • Energy Consumption on BRUKL report
        • Entering non-standard HVAC systems
        • EPBD Recast - Specifying alternative forms of energy
        • EPC and Recommendations menus
        • EPCGEN Error, no compliance report and blank results
        • EPCgen.net Activation Code
        • Excessive thermal bridging
        • External doors missing from BRUKL report
        • Fuel Heating Type
        • General Lighting output in compliance report
        • Glazing area differences
        • Glazing Light Transmittance in Part L Results
        • Heating System Controls greyed out
        • Hostel room types reverting to 24x7 Bedroom after definition
        • Inputting DHW Generator Seasonal Efficiency
        • Inputting SFP for fan coils
        • Internal Surfaces appearing in PartL U-Value checks
        • Keyword out of range: Heat SSEFF error
        • Lighting results do not match input data
        • Notional Auxiliary Energy requirements increase when using HEPA filters
        • Occupancy gains may appear different
        • Omitted Recommendations shown in Recommendations Report
        • Partition Centre Lines
        • PartL 2010 and 2013 in the same project
        • Potential Measures for Scottish EPC's
        • Power Factor and Lighting Controls
        • Project data changing after loading project into different software versions
        • Renewable fuel sources
        • Result changes between 2006, 2010 and 2013 regulations
        • Room Types and the NCM Database
        • Shell and Core Building Services can cause an error
        • The BRUKL document is listing an unexpected building type
        • The NCM modelling guide
        • Thermal Bridging/PSI values
        • Usage of Biofuels
        • U-value check in Compliance Report
        • U-Value checks not carried out
        • Version 25/26 change over notes for PartL
        • Watermarks on SBEM output documents
        • XML document is not produced
        • Zone data isn't imported into PartL 2013
      • +System Builder - Hevacomp Mechanical Design
    • +Installation and activation
    • +Troubleshooting
    • +Windows tips and tricks
    • Working From Home with Hevacomp

     
     Questions about this article, topic, or product? Click here. 

    Watermarks on SBEM output documents

      Product(s): Hevacomp Mechanical Designer
      Version(s): V8i (N/A)
      Environment: N/A
      Area: N/A
      Subarea: N/A

    Overview

    Since the introduction of the SBEM v3.5.b calculation engine it has no longer been possible to produce an EPC through software that does not contain a watermark, regardless of full energy assessor details being entered.

    Method

    To produce an EPC without a watermark, you must first lodge the EPC's XML file with the Landmark Registry. After the EPC is lodged, it is possible to download a document that does not contain a watermark.

    For information regarding this or other policy decisions for the SBEM calculation engine, contact either your accredited scheme provider or BRE directly.

    • SBEM
    • Hevacomp Mechanical Designer
    • Watermarks
    • PartL
    • Share
    • History
    • More
    • Cancel
    • Duncan Brown Created by Duncan Brown
    • When: Fri, Jun 3 2011 12:04 PM
    • Shane Regan Last revision by Bentley Colleague Shane Regan
    • When: Mon, Aug 24 2020 5:13 AM
    • Revisions: 12
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies