<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability</link><pubDate>Mon, 24 Aug 2020 09:13:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Current Revision posted to Hevacomp Wiki by Shane Regan on 8/24/2020 9:13:46 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:Arial;"&gt;If Criterion 2 of the Compliance report is showing a different overall air permeability figure to the one you believe you should be getting,&amp;nbsp; it may be that you have left your room definition set to &amp;#39;default&amp;#39; rather than individual when setting up the data.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Room Data tab in PartL is used to set up data sets for your room. These can either be a default set for multiple room definitions, or individual sets for specific zones.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When you visit the Room Data tab, it will always default to showing you the Default data set. This doesn&amp;#39;t mean that any particular zones are set to use this data. This is just allowing you to view the Default data set.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you click into &amp;quot;Individual room data&amp;quot; and select a room, again, this doesn&amp;#39;t mean that the room is set to the individual room data set, but is allowing you to view any individual data sets that may be defined.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To fix a data set to a room, you should consider the &amp;quot;Use default&amp;quot; tick box.&amp;nbsp;This option only becomes active when you are&amp;nbsp;in &amp;quot;Individual room data&amp;quot; mode. If the &amp;quot;Use default&amp;quot; box is ticked, then the room will be set to use the Default data. If &amp;quot;Use default&amp;quot; is un-ticked, then the room will be using the individual room data that is displayed.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg"&gt;&lt;img alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The air permeability figure on the output document represent the overall average based on the floor area.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For e.g.&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Consider 3 rooms, each with a floor area of 5m&amp;sup2;&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room01 and Room02 are set to use default room data with an air permeability of 10m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room03 uses individual room data with an air permeability of 8m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;The compliance report would show a total air permeability of 9.33m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Buildings below 500m&amp;sup2; of useful floor area can be exempt from a pressure test. In these instances a separate submission may be required to justify not completing a pressure test, and to confirm the air permeability used in the BER calculation is taken as 15m&amp;sup3;/(h&amp;middot;m&amp;sup2;) at 50pa.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Air permeability, SBEM, Hevacomp Mechanical Designer, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/10</link><pubDate>Wed, 02 Nov 2016 16:50:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 10 posted to Hevacomp Wiki by Duncan Brown on 11/2/2016 4:50:29 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:Arial;"&gt;If Criterion 2 of the Compliance report is showing a different overall air permeability figure to the one you believe you should be getting,&amp;nbsp; it may be that you have left your room definition set to &amp;#39;default&amp;#39; rather than individual when setting up the data.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Room Data tab in PartL is used to set up data sets for your room. These can either be a default set for multiple room definitions, or individual sets for specific zones.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When you visit the Room Data tab, it will always default to showing you the Default data set. This doesn&amp;#39;t mean that any particular zones are set to use this data. This is just allowing you to view the Default data set.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you click into &amp;quot;Individual room data&amp;quot; and select a room, again, this doesn&amp;#39;t mean that the room is set to the individual room data set, but is allowing you to view any individual data sets that may be defined.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To fix a data set to a room, you should consider the &amp;quot;Use default&amp;quot; tick box.&amp;nbsp;This option only becomes active when you are&amp;nbsp;in &amp;quot;Individual room data&amp;quot; mode. If the &amp;quot;Use default&amp;quot; box is ticked, then the room will be set to use the Default data. If &amp;quot;Use default&amp;quot; is un-ticked, then the room will be using the individual room data that is displayed.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg"&gt;&lt;img alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The air permeability figure on the output document represent the overall average based on the floor area.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For e.g.&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Consider 3 rooms, each with a floor area of 5m&amp;sup2;&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room01 and Room02 are set to use default room data with an air permeability of 10m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room03 uses individual room data with an air permeability of 8m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;The compliance report would show a total air permeability of 9.33m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Buildings below 500m&amp;sup2; of useful floor area can be exempt from a pressure test. In these instances a separate submission may be required to justify not completing a pressure test, and to confirm the air permeability used in the BER calculation is taken as 15m&amp;sup3;/(h&amp;middot;m&amp;sup2;) at 50pa.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Air permeability, SBEM, Hevacomp Mechanical Designer, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/9</link><pubDate>Wed, 02 Nov 2016 16:49:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 9 posted to Hevacomp Wiki by Duncan Brown on 11/2/2016 4:49:50 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:Arial;"&gt;If Criterion 2 of the Compliance report is showing a different overall air permeability figure to the one you believe you should be getting,&amp;nbsp; it may be that you have left your room definition set to &amp;#39;default&amp;#39; rather than individual when setting up the data.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Room Data tab in PartL is used to set up data sets for your room. These can either be a default set for multiple room definitions, or individual sets for specific zones.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When you visit the Room Data tab, it will always default to showing you the Default data set. This doesn&amp;#39;t mean that any particular zones are set to use this data. This is just allowing you to view the Default data set.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you click into &amp;quot;Individual room data&amp;quot; and select a room, again, this doesn&amp;#39;t mean that the room is set to the individual room data set, but is allowing you to view any individual data sets that may be defined.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To fix a data set to a room, you should consider the &amp;quot;Use default&amp;quot; tick box.&amp;nbsp;This option only becomes active when you are&amp;nbsp;in &amp;quot;Individual room data&amp;quot; mode. If the &amp;quot;Use default&amp;quot; box is ticked, then the room will be set to use the Default data. If &amp;quot;Use default&amp;quot; is un-ticked, then the room will be using the individual room data that is displayed.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg"&gt;&lt;img alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The air permeability figure on the output document represent the overall average based on the floor area.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For e.g.&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Consider 3 rooms, each with a floor area of 5m&amp;sup2;&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room01 and Room02 are set to use default room data with an air permeability of 10m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room03 uses individual room data with an air permeability of 8m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;The compliance report would show a total air permeability of 9.33m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Buildings below 500m&amp;sup2; of useful floor area can be exempt from a pressure test. In these instances a separate submission may be required to justify not completing a pressure test, and to confirm the air permeability used in the BER calculation is taken as 15m&amp;sup3;/(h&amp;middot;m&amp;sup2;) at 50pa.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Air permeability, SBEM, Hevacomp Mechanical Designer, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/8</link><pubDate>Tue, 10 Mar 2015 15:35:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 8 posted to Hevacomp Wiki by Shane Regan on 3/10/2015 3:35:49 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:Arial;"&gt;If Criterion 2 of the Compliance report is showing a different overall air permeability figure to the one you believe you should be getting,&amp;nbsp; it may be that you have left your room definition set to &amp;#39;default&amp;#39; rather than individual when setting up the data.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Room Data tab in PartL is used to set up data sets for your room. These can either be a default set for multiple room definitions, or individual sets for specific zones.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When you visit the Room Data tab, it will always default to showing you the Default data set. This doesn&amp;#39;t mean that any particular zones are set to use this data. This is just allowing you to view the Default data set.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you click into &amp;quot;Individual room data&amp;quot; and select a room, again, this doesn&amp;#39;t mean that the room is set to the individual room data set, but is allowing you to view any individual data sets that may be defined.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To fix a data set to a room, you should consider the &amp;quot;Use default&amp;quot; tick box.&amp;nbsp;This option only becomes active when you are&amp;nbsp;in &amp;quot;Individual room data&amp;quot; mode. If the &amp;quot;Use default&amp;quot; box is ticked, then the room will be set to use the Default data. If &amp;quot;Use default&amp;quot; is un-ticked, then the room will be using the individual room data that is displayed.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg"&gt;&lt;img alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The air permeability figure on the output document represent the overall average based on the floor area.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For e.g.&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Consider 3 rooms, each with a floor area of 5m&amp;sup2;&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room01 and Room02 are set to use default room data with an air permeability of 10m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room03 uses individual room data with an air permeability of 8m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;The compliance report would show a total air permeability of 9.33m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Buildings below 500m&amp;sup2; of useful floor area can be exempt from a pressure test. In these instances a separate submission may be required to justify not completing a pressure test, and to confirm the air permeability used in the BER calculation is taken as 15m&amp;sup3;/(h&amp;middot;m&amp;sup2;) at 50pa.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Hevacomp, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/7</link><pubDate>Tue, 09 Dec 2014 12:16:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 7 posted to Hevacomp Wiki by Duncan Brown on 12/9/2014 12:16:03 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:Arial;"&gt;If Criterion 2 of the Compliance report is showing a different overall air permeability figure to the one you believe you should be getting,&amp;nbsp; it may be that you have left your room definition set to &amp;#39;default&amp;#39; rather than individual when setting up the data.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Room Data tab in PartL is used to set up data sets for your room. These can either be a default set for multiple room definitions, or individual sets for specific zones.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When you visit the Room Data tab, it will always default to showing you the Default data set. This doesn&amp;#39;t mean that any particular zones are set to use this data. This is just allowing you to view the Default data set.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you click into &amp;quot;Individual room data&amp;quot; and select a room, again, this doesn&amp;#39;t mean that the room is set to the individual room data set, but is allowing you to view any individual data sets that may be defined.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To fix a data set to a room, you should consider the &amp;quot;Use default&amp;quot; tick box.&amp;nbsp;This option only becomes active when you are&amp;nbsp;in &amp;quot;Individual room data&amp;quot; mode. If the &amp;quot;Use default&amp;quot; box is ticked, then the room will be set to use the Default data. If &amp;quot;Use default&amp;quot; is un-ticked, then the room will be using the individual room data that is displayed.&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg"&gt;&lt;img alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The air permeability figure on the output document represent the overall average based on the floor area.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For e.g.&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Consider 3 rooms, each with a floor area of 5m&amp;sup2;&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room01 and Room02 are set to use default room data with an air permeability of 10m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Room03 uses individual room data with an air permeability of 8m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;The compliance report would show a total air permeability of 9.33m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/p&gt;
&lt;p style="text-align:justify;margin-left:30px;"&gt;Buildings below 500m&amp;sup2; of useful floor area can be exempt from a pressure test. In these instances a separate submission may be required to justify not completing a pressure test, and to confirm the air permeability used in the BER calculation is taken as 15m&amp;sup3;/(h&amp;middot;m&amp;sup2;) at 50pa.&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Hevacomp, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/6</link><pubDate>Mon, 21 Jul 2014 15:35:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 6 posted to Hevacomp Wiki by Duncan Brown on 7/21/2014 3:35:15 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;&lt;span style="font-family:Arial;"&gt;If Criterion 2 of the Compliance report is showing a different overall air permeability figure to the one you believe you should be getting,&amp;nbsp;&lt;/span&gt; it may be that you have left your room definition set to &amp;#39;default&amp;#39; rather than individual when setting up the data.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The Room Data tab in PartL is used to set up data sets for your room. These can either be a default set for multiple room definitions, or individual sets for specific zones.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;When you visit the Room Data tab, it will always default to showing you the Default data set. This doesn&amp;#39;t mean that any particular zones are set to use this data. This is just allowing you to view the Default data set.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;If you click into &amp;quot;Individual room data&amp;quot; and select a room, again, this doesn&amp;#39;t mean that the room is set to the individual room data set, but is allowing you to view any individual data sets that may be defined.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;To fix a data set to a room, you should consider the &amp;quot;Use default&amp;quot; tick box.&amp;nbsp;This option only becomes active when you are&amp;nbsp;in &amp;quot;Individual room data&amp;quot; mode. If the &amp;quot;Use default&amp;quot; box is ticked, then the room will be set to use the Default data. If &amp;quot;Use default&amp;quot; is un-ticked, then the room will be using the individual room data that is displayed.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg"&gt;&lt;img alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/sbem-air-perm.jpg" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The air permeability figure on the output document represent the overall average based on the floor area.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;For e.g.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;Consider 3 rooms, each with a floor area of 5m&amp;sup2;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;Room01 and Room02 are set to use default room data with an air permeability of 10m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;Room03 uses individual room data with an air permeability of 8m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The compliance report would show a total air permeability of 9.33m&amp;sup3;/(h&amp;middot;m&amp;sup2;)&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;Buildings below 500m&amp;sup2; of useful floor area can be exempt from a pressure test. In these instances a separate submission may be required to justify not completing a pressure test, and to confirm the air permeability used in the BER calculation is taken as 15m&amp;sup3;/(h&amp;middot;m&amp;sup2;) at 50pa.&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Hevacomp, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/5</link><pubDate>Wed, 26 Jun 2013 19:38:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Elisabeth Pry</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 5 posted to Hevacomp Wiki by Elisabeth Pry on 6/26/2013 7:38:06 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;It can appear that the air permeability figures entered into your PartL project do not match what is being seen in the results pages. To see the most likely reason for this, click on the link below.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see how to convert your projects, please click &lt;a href="/products/building/performance/m/building_performance_gallery/177322/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Hevacomp, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/4</link><pubDate>Wed, 26 Jun 2013 19:37:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Elisabeth Pry</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Elisabeth Pry on 6/26/2013 7:37:20 PM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;p&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;It can appear that the air permeability figures entered into your PartL project do not match what is being seen in the results pages. To see the most likely reason for this, click on the link below.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see how to convert your projects, please click &lt;a href="/products/building/performance/m/building_performance_gallery/177322/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Hevacomp, TechNote, selectservices, SBEM, PartL&lt;/div&gt;
</description></item><item><title>Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/3</link><pubDate>Tue, 17 Jul 2012 09:14:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Duncan Brown on 7/17/2012 9:14:49 AM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&amp;nbsp;V8i&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;It can appear that the air permeability figures entered into your PartL project do not match what is being seen in the results pages. To see the most likely reason for this, click on the link below.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see how to convert your projects, please click &lt;a href="/products/building/performance/m/building_performance_gallery/177322/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: PartL Sbem Hevacomp&lt;/div&gt;
</description></item><item><title>Part L - Defining air permeability [TN]</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/2</link><pubDate>Mon, 16 Jul 2012 13:27:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Duncan Brown on 7/16/2012 1:27:34 PM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&amp;nbsp;V8i&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;It can appear that the air permeability figures entered into your PartL project do not match what is being seen in the results pages. To see the most likely reason for this, click on the link below.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see how to convert your projects, please click &lt;a href="/products/building/performance/m/building_performance_gallery/177322/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: PartL Sbem Hevacomp&lt;/div&gt;
</description></item><item><title>Part L - Defining air permeability</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability/revision/1</link><pubDate>Mon, 11 Jul 2011 10:48:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:dd94a8e7-096d-4da0-8e65-d2ccc2d89e91</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5640/defining-air-permeability#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 7/11/2011 10:48:18 AM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&amp;nbsp;V8i&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;It can appear that the air permeability figures entered into your PartL project do not match what is being seen in the results pages. To see the most likely reason for this, click on the link below.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see how to convert your projects, please click &lt;a href="/products/building/performance/m/building_performance_gallery/177322/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: PartL Sbem Hevacomp&lt;/div&gt;
</description></item></channel></rss>