<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Gas pipe sizing - Bouyancy and Residual Pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Gas pipe sizing - Bouyancy and Residual Pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures</link><pubDate>Mon, 13 Mar 2017 12:05:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Current Revision posted to Hevacomp Wiki by Duncan Brown on 3/13/2017 12:05:44 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Netsys Gas&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;The Netsys Gas Pipe sizing program considers Buoyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure&amp;nbsp;= Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;The residual pressures report shows figures rounded to whole numbers. &lt;br /&gt;This is reflected in the calculation above.&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and Residual Pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/12</link><pubDate>Fri, 18 Nov 2016 17:22:01 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 12 posted to Hevacomp Wiki by Duncan Brown on 11/18/2016 5:22:01 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Netsys Gas&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;The Netsys Gas Pipe sizing program considers Buoyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure&amp;nbsp;= Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;The residual pressures report shows figures rounded to whole numbers. &lt;br /&gt;This is reflected in the calculation above.&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and Residual Pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/11</link><pubDate>Tue, 27 Sep 2016 15:31:32 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 11 posted to Hevacomp Wiki by Shane Regan on 9/27/2016 3:31:32 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Netsys Gas&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;The Netsys Gas Pipe sizing program considers Buoyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure&amp;nbsp;= Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above.&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/10</link><pubDate>Fri, 19 Feb 2016 11:47:09 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 10 posted to Hevacomp Wiki by Shane Regan on 2/19/2016 11:47:09 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Netsys Gas&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure&amp;nbsp;= Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:x-small;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/9</link><pubDate>Fri, 21 Aug 2015 09:57:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 9 posted to Hevacomp Wiki by Shane Regan on 8/21/2015 9:57:27 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Netsys Gas&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure - Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:x-small;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/8</link><pubDate>Tue, 10 Mar 2015 12:39:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 8 posted to Hevacomp Wiki by Duncan Brown on 3/10/2015 12:39:41 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure - Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:x-small;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/7</link><pubDate>Tue, 02 Dec 2014 14:16:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 7 posted to Hevacomp Wiki by Duncan Brown on 12/2/2014 2:16:13 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure - Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:x-small;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/6</link><pubDate>Tue, 02 Dec 2014 14:15:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 6 posted to Hevacomp Wiki by Duncan Brown on 12/2/2014 2:15:25 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. Consider this small Netsys Gas system:&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;The columns in the above report are calculated with the following methods:&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;Available pressure - Source pressure - Pressure drop in section&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;Where the buoyancy effect is calculated using this formula:&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;font-size:small;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:x-small;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;The Netsys Gas program uses the following Gas densities:&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Natural Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.68&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Town Gas&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.54&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Butane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;2.48&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Air&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.22&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Carbon Dioxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.72&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Methane&lt;/td&gt;
&lt;td style="text-align:center;"&gt;0.67&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Nitrogen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Nitrous Oxide&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.84&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Oxygen&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.33&lt;/td&gt;
&lt;td&gt;&amp;nbsp;Exhaust Gasses&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.00&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/5</link><pubDate>Mon, 07 Jul 2014 14:30:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 5 posted to Hevacomp Wiki by Duncan Brown on 7/7/2014 2:30:35 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program. &lt;/span&gt;&lt;span style="font-size:small;"&gt;Consider this small Netsys Gas system:&lt;/span&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/6215.Bouyancy1.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy1.jpg"&gt;&lt;/a&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy1.jpg"&gt;&lt;/a&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy2.jpg"&gt;&lt;/a&gt;This system will produce the following sizing results:&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/1106.bouyancy2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;And the Residual Pressures report for the system:&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy3.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;The columns in the above report are calculated with the following methods:&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;em&gt;&lt;strong&gt;&lt;span style="font-size:small;"&gt;Available pressure - Source pressure - Pressure drop in section&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;&lt;span style="font-size:small;"&gt;Required pressure = Outlet pressure + Section pressure drop - Buoyancy effect&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/em&gt;&lt;em&gt;&lt;strong&gt;&lt;span style="font-size:small;"&gt;Residual pressure = Available pressure - Required pressure&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/em&gt;&lt;span style="font-size:small;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;Where the buoyancy effect is calculated using this formula:&lt;/span&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy4.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;font-size:small;"&gt;The example system above uses Natural Gas with a buoyancy of 0.68&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy5.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;So for Section 3 in our example Gas layout:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy6.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="font-size:x-small;"&gt;The residual pressures report shows figures rounded to whole numbers. This is reflected in the calculation above&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Notes&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;The Netsys Gas program uses the following Gas densities:&lt;/span&gt;&lt;/p&gt;
&lt;table style="width:100%;" border="0" cellspacing="1" cellpadding="1"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;Natural Gas&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;0.68&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Town Gas&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;0.54&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Butane&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;2.48&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Propane&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.85&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;Air&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;1.22&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Carbon Dioxide&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;1.72&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Methane&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;0.67&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Nitrogen&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;1.16&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;Nitrous Oxide&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;1.84&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Oxygen&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;1.33&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;span style="font-size:small;"&gt;&amp;nbsp;Exhaust Gasses&lt;/span&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;span style="font-size:small;"&gt;1.00&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:center;"&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;&lt;/span&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/4</link><pubDate>Mon, 07 Jul 2014 14:14:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Duncan Brown on 7/7/2014 2:14:15 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;This document explains how the buoyancy effect is considered in the Residual pressure report in the Netsys Gas program.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;Consider this small Netsys Gas system:&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy1.jpg"&gt;&lt;/a&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Bouyancy1.jpg"&gt;&lt;/a&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/bouyancy2.jpg"&gt;&lt;/a&gt;This will&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see the methodoligy used in the Netsys program, please click &lt;a href="/products/building/performance/m/building_performance_gallery/179107/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/3</link><pubDate>Tue, 25 Jun 2013 13:44:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Elisabeth Pry</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Elisabeth Pry on 6/25/2013 1:44:11 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see the methodoligy used in the Netsys program, please click &lt;a href="/products/building/performance/m/building_performance_gallery/179107/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Gas Bouyancy, SELECTservices, Residual Pressure, Hevacomp Mechanical Designer, TechNote, netsys&lt;/div&gt;
</description></item><item><title>Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/2</link><pubDate>Tue, 17 Jul 2012 09:05:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Duncan Brown on 7/17/2012 9:05:41 AM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see the methodoligy used in the Netsys program, please click &lt;a href="/products/building/performance/m/building_performance_gallery/179107/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Netsys Gas Bouyancy Residual Pressure&lt;/div&gt;
</description></item><item><title>Netsys - Bouyancy and residual pressures</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures/revision/1</link><pubDate>Mon, 16 Jul 2012 11:16:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6d574b4e-33aa-4a7d-bf7b-6c5f28ed29cf</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5682/gas-pipe-sizing-bouyancy-and-residual-pressures#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 7/16/2012 11:16:10 AM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The Netsys Gas Pipe sizing program considers Bouyancy and Residual Pressures during the calculation process.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To see the methodoligy used in the Netsys program, please click &lt;a href="/products/building/performance/m/building_performance_gallery/179107/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Netsys Gas Bouyancy Residual Pressure&lt;/div&gt;
</description></item></channel></rss>