<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type</link><pubDate>Mon, 24 Aug 2020 09:13:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Current Revision posted to Hevacomp Wiki by Shane Regan on 8/24/2020 9:13:47 AM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type and this will be displayed on the EPC&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine considers both Heating and Hot Water systems when deciding which system is considered as the main heating system. In the example shown here, HWS has been defined&amp;nbsp;with Grid Supplied Electricity, the Heating system with a Gas boiler. The demand on the HWS system exceeds that of the heating system. Under these circumstances SBEM considers the HWS system to be the main heating system.&lt;br /&gt;&lt;br /&gt;If you consider the Energy Report, you can clearly see the HWS usage is higher than the Heating system usage.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM, Hevacomp Mechanical Designer, PartL, Heating Fuel&lt;/div&gt;
</description></item><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/7</link><pubDate>Wed, 02 Nov 2016 17:16:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 7 posted to Hevacomp Wiki by Duncan Brown on 11/2/2016 5:16:42 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type and this will be displayed on the EPC&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine considers both Heating and Hot Water systems when deciding which system is considered as the main heating system. In the example shown here, HWS has been defined&amp;nbsp;with Grid Supplied Electricity, the Heating system with a Gas boiler. The demand on the HWS system exceeds that of the heating system. Under these circumstances SBEM considers the HWS system to be the main heating system.&lt;br /&gt;&lt;br /&gt;If you consider the Energy Report, you can clearly see the HWS usage is higher than the Heating system usage.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM, Hevacomp Mechanical Designer, PartL, Heating Fuel&lt;/div&gt;
</description></item><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/6</link><pubDate>Tue, 17 Mar 2015 11:36:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Stephen Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 6 posted to Hevacomp Wiki by Stephen Brown on 3/17/2015 11:36:25 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type and this will be displayed on the EPC&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine considers both Heating and Hot Water systems when deciding which system is considered as the main heating system. In the example shown here, HWS has been defined&amp;nbsp;with Grid Supplied Electricity, the Heating system with a Gas boiler. The demand on the HWS system exceeds that of the heating system. Under these circumstances SBEM considers the HWS system to be the main heating system.&lt;br /&gt;&lt;br /&gt;If you consider the Energy Report, you can clearly see the HWS usage is higher than the Heating system usage.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Heating Fuel&lt;/div&gt;
</description></item><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/5</link><pubDate>Tue, 09 Dec 2014 17:08:52 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 5 posted to Hevacomp Wiki by Duncan Brown on 12/9/2014 5:08:52 PM&lt;br /&gt;
&lt;p style="text-align:justify;"&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type and this will be displayed on the EPC&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine considers both Heating and Hot Water systems when deciding which system is considered as the main heating system. In the example shown here, HWS has been defined&amp;nbsp;with Grid Supplied Electricity, the Heating system with a Gas boiler. The demand on the HWS system exceeds that of the heating system. Under these circumstances SBEM considers the HWS system to be the main heating system.&lt;br /&gt;&lt;br /&gt;If you consider the Energy Report, you can clearly see the HWS usage is higher than the Heating system usage.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Heating Fuel&lt;/div&gt;
</description></item><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/4</link><pubDate>Wed, 23 Jul 2014 15:06:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Duncan Brown on 7/23/2014 3:06:16 PM&lt;br /&gt;
&lt;p style="text-align:justify;"&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type and this will be displayed on the EPC&lt;/span&gt;&lt;span style="font-size:small;"&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-1.jpg" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The SBEM calculation engine considers both Heating and Hot Water systems when deciding which system is considered as the main heating system. In the example shown here, HWS has been defined&amp;nbsp;with Grid Supplied Electricity, the Heating system with a Gas boiler. The demand on the HWS system exceeds that of the heating system. Under these circumstances SBEM considers the HWS system to be the main heating system.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:small;"&gt;If you consider the Energy Report, you can clearly see the HWS usage is higher than the Heating system usage.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/heating-fuel-type-_2D00_-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;&lt;/span&gt;&amp;nbsp;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Heating Fuel&lt;/div&gt;
</description></item><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/3</link><pubDate>Wed, 26 Jun 2013 19:49:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Elisabeth Pry</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Elisabeth Pry on 6/26/2013 7:49:10 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type under certain circumstances.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To examine the reason why this may happen, click &lt;a href="/products/building/performance/m/building_performance_gallery/179150/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, SBEM, TechNote, Heating Fuel&lt;/div&gt;
</description></item><item><title>Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/2</link><pubDate>Tue, 17 Jul 2012 09:16:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Duncan Brown on 7/17/2012 9:16:49 AM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type under certain circumstances.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To examine the reason why this may happen, click &lt;a href="/products/building/performance/m/building_performance_gallery/179150/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM Heating Fuel&lt;/div&gt;
</description></item><item><title>Part L - Fuel Heating Type</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type/revision/1</link><pubDate>Mon, 16 Jul 2012 13:29:41 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:48f2f9c2-61bb-4fa7-b8ef-ffe497b1b97f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/5685/fuel-heating-type#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 7/16/2012 1:29:41 PM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;The SBEM calculation engine can consider the HWS system as the main fuel heating type under certain circumstances.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-size:small;"&gt;To examine the reason why this may happen, click &lt;a href="/products/building/performance/m/building_performance_gallery/179150/download.aspx"&gt;here&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM Heating Fuel&lt;/div&gt;
</description></item></channel></rss>