Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
Hevacomp Wiki Hevacomp General Information
    • Sign In
    • All tags
    • DDB
    • 26.06
    • 380
    • 53
    • Bentley Hevacomp
    • Casual
    • cibse
    • CIBSE Gain
    • Daylight factors
    • design database
    • Energy
    • fabric
    • Floor heights
    • gain
    • Hevacomp
    • Hevacomp Mechanical Designer
    • HWS Energy Use
    • installation
    • Latent
    • mat
    • netsys
    • Roof
    • RTE
    • Run Time Error
    • set up
    • Type
    • Assigning Windcatchers through Flowpath Data

      Krishnendu Paul
      Krishnendu Paul
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The article provides detailed guidance of how to model windcatchers and assign…
      • over 1 year ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Roof changes not reflected in model

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Changing the roof type in Floors/Roofs isn't reflected in the model. Solution…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Energy Calculation - HWS and occupancy

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Mechanical Designer Subarea: Design Database Problem Hot Water Usage is reported as zero upon running the Design Database Energy…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Glazing Data - Additional glazing is available

      Duncan Brown
      Duncan Brown
      Product(s): Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When a new Design Database project is created, a default list of glazing types is included…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Omitted Recommendations shown in Recommendations Report

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Version(s): V26 Environment: N/A Area: Design Database Subarea: Part L Problem 'Omit Recommendation' selections are not reflected in the Recommendations Report. Solution…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain calculation - Importance of accurate input data

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Results Overview Unusual results are likely to occur if Building model data is inadequate. Method Comprehensive…
      • over 4 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Displaying Building Input Data

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Databse Subarea: Reports Overview You may wish to review your project input data. Method The Schedule and Print functions…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Hevacomp Mechanical Designer

      Duncan Brown
      Duncan Brown
      Design Database and Netsys Pipe and Duct sizing
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain calculation - Why are there blank lines in my Gain results?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Results for CIBSE gain, Carrier gain and Airah gain contain a number of blank…
      • over 4 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Calculations - Occupancy and heat gains

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The number of occupants and activity with which they are employed will have an…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD mode and Room data mode

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Describing the difference between CAD and Room Data mode. Method There are two…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain Calculation - Load types

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The following is a breakdown of components that make up the gains in the CIBSE Heat…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Adding atrium style spaces to a project

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on modeling Atrium type spaces in Design Database…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Adding different roof section types

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The roof construction fabric can be changed as you are adding roof sections. Method…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Gap Between Roof And Walls

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When modelling a roof in Hevacomp a space can sometimes appear between the roof…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Version 26 - Run Time Error 380 in MAT after installation

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (25) Environment: N/A Area: N/A Subarea: N/A Introduction NOTES: This is applicable to older installations of V26 only You do NOT need…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Version 26 - Run Time Error 53 in MAT after installation

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (25) Environment: N/A Area: N/A Subarea: N/A Introduction NOTES: This is applicable to older v26 installations. You do NOT need to un…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import Issues - Drawing is too large error

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document details what to do should you encounter the following "Drawing is…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Editing project data - Default Data vs Global Change

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on the difference between CAD Input Default Data…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain calculation - Solar gains at night

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview CIBSE Gain results can often display Solar Gains at night, for example: Explanation…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Design Database hangs after opening project, or "Timeout accessing the database" error occurs

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Design Database projects may stop functioning or generate a Timeout error on opening…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Daylight Calculations in Design Database

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Daylight factors can be calculated for Design Database projects. Method An…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Changing Floor Heights

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on how to change Floor heights in Design Database…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Elevating roofs using Roof Points

      Krishnendu Paul
      Krishnendu Paul
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When designing a roof for a Design Database project, you may not be able to elevate…
      • over 1 year ago
      • Hevacomp
      • Hevacomp Wiki
    • View related content throughout Hevacomp
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies