Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
Hevacomp Wiki Hevacomp General Information
    • Sign In
    • All tags
    • design database
    • 26.06
    • cibse
    • CIBSE Gain
    • Daylight factors
    • DDB
    • DXF
    • Floors
    • gain
    • green building
    • Hevacomp
    • Hevacomp Mechanical Design
    • Hevacomp Mechanical Designer
    • Input
    • installation
    • mat
    • Nimbus
    • Roof
    • Room positions
    • room set point
    • RTE
    • Run Time Error
    • SELECTservices
    • Setup
    • Simulator
    • TechNote
    • CAD Model Design - Roof changes not reflected in model

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Changing the roof type in Floors/Roofs isn't reflected in the model. Solution…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Glazing Data - Additional glazing is available

      Duncan Brown
      Duncan Brown
      Product(s): Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When a new Design Database project is created, a default list of glazing types is included…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import issues - Drawing is inverted

      Duncan Brown
      Duncan Brown
      Product(s): Mechanical Designers - Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Importing a DXF is showing the drawing inverted in either the X or Y…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain calculation - Importance of accurate input data

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Design Database Subarea: Results Overview Unusual results are likely to occur if Building model data is inadequate. Method Comprehensive…
      • over 4 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model design - Window is too small

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When adding a window or door to a surface, you may receive a "Window is too small…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain calculation - Allowing temperatures to rise

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (V26) Environment: N/A Area: N/A Subarea: N/A Overview The CIBSE gain calculation contains an option to allow the temperature to rise. …
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import - Changing a DXF drawing

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Design Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Overview If a project design is modified, you may wish to change the DXF for…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Hevacomp General Information

      Shane Regan
      Shane Regan
      We recommend bookmarking this page for easy access Hevacomp final version is V8i SS1 SP10 (V8i SS1 CP3 (06/16)) Should you require assistance installing, please post any queries in the forum
      • 1 month ago
      • Hevacomp
      • Hevacomp Wiki
    • Regional Settings for International Windows Versions

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical and Electrical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Windows settings for numeric symbols can cause issues when running…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Design Database - Hevacomp Mechanical Designer

      Duncan Brown
      Duncan Brown
      Design Database Load calculations
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain calculation - Why are there blank lines in my Gain results?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Results for CIBSE gain, Carrier gain and Airah gain contain a number of blank…
      • over 4 years ago
      • Hevacomp
      • Hevacomp Wiki
    • How to place rooms within rooms

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview In some instances it may be desirable to embed rooms within other rooms. Method…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • How to use Room Multipliers

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview There may be situations where you require a large number of rooms in a project…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Calculations - Occupancy and heat gains

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The number of occupants and activity with which they are employed will have an…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • How to import a gbXML file

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview gbXML (Green Building XML) is a very useful format for transferring building…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD mode and Room data mode

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Describing the difference between CAD and Room Data mode. Method There are two…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Adding atrium style spaces to a project

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document provides guidance on modeling Atrium type spaces in Design Database…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain Calculation - Why does the graph show double the table results?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When producing results in the CIBSE Gains program, the graph is showing double…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Considering split level floors?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview There may be times when you wish to consider a split level floor in a project…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import - Re-aligning Rooms and DXF outline

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When viewing the Design Database 3D Cad model, the floors in the project appear…
      • over 4 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import issues - Lines are missing from drawing

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Method When importing a DXF into the Design Database CAD Input module, vectors from the…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CIBSE Gain Calculation - Load types

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The following is a breakdown of components that make up the gains in the CIBSE Heat…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Version 26 - Run Time Error 380 in MAT after installation

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (25) Environment: N/A Area: N/A Subarea: N/A Introduction NOTES: This is applicable to older installations of V26 only You do NOT need…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Version 26 - Run Time Error 53 in MAT after installation

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (25) Environment: N/A Area: N/A Subarea: N/A Introduction NOTES: This is applicable to older v26 installations. You do NOT need to un…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import Issues - Drawing is too large error

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Design Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document details what to do should you encounter the following "Drawing is…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • View related content throughout Hevacomp
    • More
    • Cancel
    >
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies