When Project Manager is opened the following error message is displayed. It may occur at startup if the software is configured to open Project Manager automatically.
Internal ErrorError Message: The network path was not found. (Exception from HRESULT: 0x80070035)TargetSite: Void ThrowExceptionForHRInternal(Int32, IntPtr)DeclaringType: System.Runtime.InteropServices.MarshalAttributes: internal staticMemberType: Method
This seems to have resulted from bad or obsolete data in the user application data folder, possibly an old path in the MRU.xml (Most Recently Used) file. In one case the problem happened after upgrading Bentley Substation in a Citrix environment.
Close the software.
Delete or rename the user application data folder for the software.Application Data (per-user configuration) - SubstationApplication Data (per-user configuration) - Promis.e
The network path was not found. (Exception from HRESULT: 0x80070035)