After clicking OK on the New Page dialog, error message(s) are displayed:
Internal ErrorAPI Error Message: Could not find file '....ANSI-IEEE_T.Dwg'TargetSite: Void WinIOError(Int32, System.String)DeclaringType: System.IO.__ErrorAttributes: internal staticMemberType: MethodStackTrace: C:\ProgramData\Bentley\Promise V8i\Config\LastError.txtProduct Version: Promise V8i (SELECTseries 8)DB Version: SQLServer 8.1.42
and no page is created, or
ErrorAn error occured when savingDetail:Object reference not set to an instance of an object.
is displayed followed by:
Internal ErrorUI Error Message: Object reference not set to an instance of an object.TargetSite: ECT.ECAD.API.Page New(ECT.ECAD.API.PageSetting)DeclaringType: ECT.ECAD.API.PagesAttributes: publicMemberType: Method
and a page drawing may appear on the screen.
These error messages can occur after migrating from Promis.e for AutoCAD to Promis.e Standalone. The problem is that the ProjectOptions.xml file that the project(s) is based on still points to DWG files instead of DGN files as seed files for new pages.
Note: when Promis.e for AutoCAD projects are migrated to Promis.e Standalone V8i SELECTseries 6 and above, the seed file extensions in the Project.Options.xml file in the project will get converted to ".dgn". But there is no migration function for template ProjectOptions.xml files.
Moving From Promis.e for AutoCAD to Promis.e Standalone
Template Project Options - V8i
Keywords: occurred, TFS 6102