In Promis.e Standalone, when opening pages of a project that was created in Promis.e for AutoCAD, various error messages occur:
Error
An error occured when saving
Detail:Object reference not set to an instance of an object.
Internal Error
API Error Message: Object reference not set to an instance of an object.
TargetSite: Boolean Open(Boolean)
DeclaringType: ECT.ECAD.API.Page
Attributes: public
MemberType: Method
Internal Error
API Error Message: Input string was not in a correct format.
TargetSite: Void StringToNumber(System.String, System.Globalization.NumberStyles, NumberBuffer ByRef, System.Globalization.NumberFormatInfo, Boolean)
DeclaringType: System.Number
Attributes: private static
MemberType: Method
Internal Error
API Error Message: Object reference not set to an instance of an object.
TargetSite: Void docActivated(System.String)
DeclaringType: ECT.ECAD.API.DocEventHandler
Attributes: public static
MemberType: Method
Internal Error
UI Error Message: Object reference not set to an instance of an object.
TargetSite: Boolean RestoreFromXData()
DeclaringType: PanduitWire.PanduitWireForm
Attributes: private
MemberType: Method
These messages can occur when the proper workflow to migrate the project has not been followed.
In Promis.e for AutoCAD right-click the project and select [[Backup Project|Backup]].
On the resulting Backup Project dialog, set the Save files in MicroStation compatible format check box, click OK.
[[Restore Project|Restore the resulting file]] in Promis.e Standalone.
[[Moving From Promis.e for AutoCAD to Promis.e Standalone]]
Original Author: | Matt_P |