Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
OpenUtilities
OpenUtilities Wiki
Resolved issues in Bentley Substation CONNECT Edition Update 2, 10.02.00.31
Sign In
+
OpenUtilities
Access Service Request Manager
Design Features - promis.e Functionality - Promis.e Standard
+
OpenUtilities sisHYD Multi Utility
+
OpenUtilities sisNET - English
-
OpenUtilities Substation
-
CONNECT Edition - OpenUtilities Substation
+
3D Layout Features - OpenUtilities-Substation
+
Administration Features - OpenUtilities Substation
+
Automation Feature
+
Component management - OpenUtilities Substation CONNECT
+
Components Features - Substation CONNECT
+
Construction Drawing - Openutilities Substation CONNECT
+
Database Platform Support - OpenUtilities Substation
+
Drawing Managment - OpenUtilities Substation
+
Installation_Configuration - Bentley Substation CONNECT Edition
+
Maintenance Feature - Open Utilities Substation CONNECT
+
Migration - OpenUtilities Substation CONNECT
+
OS & Hardware Support - OpenUtilities Substation CONNECT
+
Panel Layout- Substation CONNECT
+
Power Platform Support - Substation CONNECT
+
Print and Plot feature
+
Print and Publish feature
+
Project Management - OpenUtilities Substation CE
+
ProjectWise Integration - OpenUtilities Substation CONNECT
+
Replace Device ID - Find_Replace - OpenUtilities Substation
+
Reports_Output Features - OpenUtilities Substation CONNECT
-
Resolved issues in OpenUtilities Substation Releases
Resolved issues in Bentley Substation CONNECT Edition, 10.00.00.232
Resolved issues in Bentley Substation CONNECT Edition Update 1, 10.01.00.23
Resolved issues in Bentley Substation CONNECT Edition Update 2, 10.02.00.31
Resolved issues in Bentley Substation CONNECT Edition Update 3, 10.03.00.42
Resolved issues in Bentley Substation CONNECT Edition Update 4, 10.04.00.30
Resolved issues in Bentley Substation CONNECT Edition Update 5, 10.05.00.35
Resolved issues in OpenUtilities Substation CONNECT Edition 2023
Resolved issues in OpenUtilities Substation CONNECT Edition Update 10, 10.10.00.20
Resolved issues in OpenUtilities Substation CONNECT Edition Update 11, 10.11.00.22
Resolved issues in OpenUtilities Substation CONNECT Edition Update 12, 10.12.00.60
Resolved issues in OpenUtilities Substation CONNECT Edition Update 13, 10.13.00.84
Resolved issues in OpenUtilities Substation CONNECT Edition Update 14, 10.14.00.92
Resolved issues in OpenUtilities Substation CONNECT Edition Update 15, 10.15.00.57
Resolved issues in OpenUtilities Substation CONNECT Edition Update 6, 10.06.00.22
Resolved issues in OpenUtilities Substation CONNECT Edition Update 7, 10.07.00.46
Resolved issues in OpenUtilities Substation CONNECT Edition Update 8, 10.08.00.34
Resolved issues in OpenUtilities Substation CONNECT Edition Update 9 Refresh 1, 10.09.01.20
Resolved issues in OpenUtilities Substation CONNECT Edition Update 9 Refresh 2, 10.09.02.23
Resolved issues in OpenUtilities Substation CONNECT Edition Update 9, 10.09.00.10
+
Wire Numbering - Substation CONNECT
+
Wiring Feature - OpenUtilities Substation
+
3D Layout Features - Bentley Substation
About Bentley Substation
+
Administration Features - Bentley Substation
+
Automation Features - Bentley Substation
+
Component Management - Bentley Substation
+
Construction Drawings - Bentley Substation
+
Database Platform Support - Bentley Substation
+
Grounding Grid - Bentley Substation
How to log Service Request
+
Installation_Configuration - Bentley Substation
+
Interoperability - Bentley Substation
+
PowerPlatform Support - Bentley Substation
+
Project Management - Bentley Substation
+
ProjectWise Integration - Bentley Substation
Working from home with OpenUtilities Substation
Promis.e Paths
+
Promis.e Wiki
Replace Family - Find_Replace - Promis.e
SQL Server Login
Questions about this article, topic, or product? Click here.
Resolved issues in Bentley Substation CONNECT Edition Update 2, 10.02.00.31
Product:
Bentley Substation
Generation:
CONNECT Edition
Version:
Update 2, 10.02.00.31
Defect Number
Description
735155
The BOM_Grounding_Grid report did not recognize grounding grid rods that were placed independently of the Place Grid dialog.
947607
The Move command was unable to move A mesh element object.
339004
When placing a hook point with a magenta colored leg and saving the symbol the color would change to fuchsia.
350503
Create a family with terminal symbols using Family on Fly created cross reference text at the terminal symbols which should not have been there since it's now a family.
701732
The Align components command used the wrong element selection tool.
803336
The performance of loading the Insert Symbol by ID dialog has been significantly improved.
798131
The performance of inserting a macro has been improved.
729982
The three fields, Description1 - 3 shown in the File Manager view of the Project Publisher get their values from the variables you assign to them in the Format>General tab's 'Index Page Descriptions.' The problem is that in order for this to work you have to use these variables in your title block and have that title block assigned to the page in order for it to appear in the PDF report. This should not be a requirement since the page attribute data should be in the project database.
810455
The time it takes to load the software's start screen would increase dramatically depending on the number of worksets that you had created. Now the load time has been improved greatly and is less influenced by the number of worksets.
912212
The PLC Generator was not able to properly create the ladder diagrams using the example Excel file provided with the software.
898558
In the Symbol Creation Wizard, we cannot change the AccuSnap and grid toggle while in a placement function such as placing a device tag attribute.
810626
After moving the PRP on the 3D Layout mode drawing and using the Update Substation Object command to Update a cable object will cause the cable to be moved to another position.
816279
The Dimension Depth feature cannot calculate the correct dimension depth for the 3D objects.
149010
Some variables that were used in expressions in the options dialog were hard coded as English text.
730355
Fixed some inconsistent capitalization issues in various tabs of the Project Publisher dialog.
923577
The software was not able to save new title blocks to a ProjectWise folder.
900442
If you modify a symbol in Symbol Creation and save it the software creates duplicate elements in the definition of the symbol.
909577
When selecting multiple overhead cables and masts and running lightning protection you may get an error in the message center that says, "A CSG operation failed in Final merge." The surfaces are not united.
901084
Some symbols preview are cut off and some symbols are not previewed at all in the Insert Symbol and Catalog Manager dialogs.
362579
Attempting to use the Replace Family command to replace a cable family fails with an error message.
485480
If two users connect to the same project database, but one uses a different capitalization for the name of the database in his setup configuration it can cause issues in a multi-user environment. If the first user creates a project the second user won't be able to copy or move pages from that project.
726837
When assigning a part number that calls out a different family than is currently assigned to a device the following message should have been displayed, but was not coming up, "The part number you have selected does not match the existing family. If you choose to assign this part number the software will ask you to exchange the existing family. Are you sure you want to do this?"
489146
Some grounding grid parts listed twice on Substation BOM reports.
389922
The Installation and Location selections in the Substation Object settings dialog was not updating to list the values used in the current project.
730411
The "Part document from" pull-down in the Project Publisher's Format>General tab contained duplicate entries.
730565
When publishing to PDF some title block variables were not exported correctly.
205521
The software should change the sag value in Cable/Bus Object Settings dialog after switch the design file working unit.
885720
The drawing mode names displayed for each page in the Project Manager could not be localized in other languages.
906076
An error occurs when you attempt to reopen pages after using Project Publisher to publish the pages with the export title block option enabled. The alert indicated the DGN format was unrecognized in that session of the software.
746544
When using Project API Builder to rename a page's installation and location in an IEC standard project the API builder could not insert any macro or component on the page.
902328
When integrated with ProjectWise, the title blocks, macros and families in the IEC catalog could not be used in an IEC project if the software was installed with a default standard of ANSI-IEEE.
729988
While the Project Publisher>File Manager dialog is open use the Project Manager to create another page in the current project. If you return to the Project Publisher the Refresh button fails to update the list of pages to include the new page you just created.
799122
The Options>Validation Prompts, the Prompt for saving page when switching pages toggle didn't work when switching pages.
802059
If you added an additional catalog path in the Modify Project>Content tab and then Created a new family the new catalog path was not available to save the family to.
858213
There was an invalid symbol name entry appearing in the index of the SUBSTATION_IEEE catalog that has now been removed.
865236
Some dialogs in the Panduit tools could not be localized in other languages.
555891
When placing a cable on a 3D layout drawing and entering a blank value for the sag algorithm variables you get a warning message. After clicking OK to the message and switching to another sag option an error occurs.
900540
Clicking the Parts Database Edit button in the Modify Project dialog could result in an error.
899885
Using the array toggle In Symbol Creation for placing symbol text or PLC attributes would place the attributes with a strange offset that did not match the array settings that you entered.
902348
Selecting the Edit Part database button in the Modify Project dialog resulted in an error.
915994
When the Windows DPI is set to 150% the File > Settings > Configuration > ProjectWise Configuration dialog will be truncated.
922296
The Project Manager supported multiple thumbnail sizes for previewing drawings, but some of these sizes distorted the image of the preview because it had to scale the image. Now we only support the thumbnail size that is persisted in the DGN file.
923576
When integrated with ProjectWise create a new page and browse for a title block to apply to the page. The path to the title blocks in the catalog was pointing to a local DMS path instead of to the PW server path.
923578
The Page Format Designer was not creating page formats in the proper ProjectWise path which resulted in an error when you attempted to assign the page format to a page.
923579
Selecting the Edit Part database button in the Modify Project dialog displayed the local DMS folder rather than the PW server path.
703451
Changing the thumbnail size of pages in the Project Manager could cause the listing of the thumbnails to align in a single column rather than in rows. Now we only support one thumbnail size so this issue no longer occurs.
872713
The category names for grouping variables in the Title Block Wizard could not be localized in other languages.
858706
When restoring sample projects the software was unexpectedly changing the default catalog paths.
855416
When initially opening a page of a project stored in ProjectWise the View>Display> grid button in the ribbon menu had the wrong selection status. If the grid was displayed the button should have been selected.
921216
The software would crash when using the update hook point command from the Hook Point Manager to update a one-point hook point.
715780
The Insert Substation Object dialog failed to list any repeating objects like fences even when the Repeating radio button was selected.
911046
When switching projects in the Project Manager the list of reference files for the opened page was not being refreshed properly.
883378
In the Replace Part Number dialog entering a second part number in the data grid caused the first entered part number to unnecessarily scroll up so that it was no longer in view and you had to scroll the dialog back down again.
913044
The balloon leader color should be the same color as the balloon circle.
962957
The Replace Symbol Text dialog had a an improper label of "ReplaceSymbols|Attributes_PRO001" which has been corrected.
862581
The help button in the New/Modify family dialog >Connection Points dialog did not display the help topic.
733888
Several labels in the Wire Sizing dialog could not be localized in other languages.
685677
Some wire property names in the Wire Manager dialog could not be localized in other languages.
913062
In the Chinese version, the Wire Diagram Settings dialog had some controls that were being truncated.
945297
The Substation Move Object command failed to move a DTM object type.
816300
The software cannot maintain the Project Settings Profile name in the 3D Substation Layout dialog.
CONNECT Edition
10.02.00.31
Bentley Substation
en
Resolved Issues