Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
elcoCAD | Promis.e
  • Product Communities
  • More
elcoCAD | Promis.e
elcoCAD | Promis.e Wiki How to Assign Same Level to Different Drawing Elements
    • Sign in
    • +Electrical and Instrumentation - Wiki
    • -Bentley Raceway and Cable Management
      • -CONNECT Edition - Bentley Raceway and Cable Management
        • +Resolved issues in Bentley Raceway and Cable Management Releases
        • How to consider Bend Radius when Routing Cables
        • How to Import Cable List into BRCM CONNECT
        • How to install BRCM CONNECT Edition
        • +Installation_Configuration - BRCM CONNECT
        • +Project Setup- Bentley Raceway and Cable Management
        • -Raceway IDs - Bentley Raceway and Cable Management CONNECT
          • How to Assign Same Level to Different Drawing Elements
          • How to configure Raceway IDs in BRCM CONNECT
          • How to Define Raceway ID while Routing Raceway in BRCM CONNECT
        • +Reports - Output Manager - BRCM CONNECT Edition
      • +V8i - Bentley Raceway and Cable Management
    • +Bentley Substation
    • +Promis.e

    You are currently reviewing an older revision of this page.

    • History View current version

    How to Assign Same Level to Different Drawing Elements

    9:01 AM

      Product(s): Bentley Raceway and cable Management
      Version(s): 10.03.00.25
      Environment: N/A
      Area: Raceway IDs
      Subarea: N/A

    Background

    There was a design restriction in previous versions of BRCM which restricted the user from assigning the same level to different drawing elements.
    For instance, in previous versions of BRCM, Equipment and Equipment id were on different levels and the user was not allowed to assign them the same level.

    In the latest update i.e. BRCM CONNECT Edition Update 3, users can assign the same levels to different drawing elements according to the steps provided below.

    Steps to Accomplish

    1. Select options dialog under Manage.


    2. In options, select CAD standards, under Levels you can see that Equipment and Equipment ID both have different levels.


    3. Double click on Equipment id to edit Level, here E-PANEL.
      Click Apply and then OK.


    4.  Go to Equipment & Cable and select Equipment Manager.


    5. Under Equipment Manager dialog, Select equipment e.g. Panel and Press OK.
    6. Provide a name to Equipment ID from EQP Macro.


    7. Right click the equipment to see properties.
      You can see the level assigned to the element by Expanding Cell: brcm_eqp3d.
    8. Select the Equipment Tag assigned to the equipment and right click to see the properties.



     

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • User Management
    • Licensing Manager
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2019 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies