Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
elcoCAD | Promis.e
  • Product Communities
  • More
elcoCAD | Promis.e
elcoCAD | Promis.e Wiki Error - Title block name is invalid
    • Sign in
    • +Electrical and Instrumentation - Wiki
    • +Bentley Raceway and Cable Management
    • +Bentley Substation
    • -Promis.e
      • +CONNECT Edition - Promis.e
      • V8i - Promis.e
      • About Promis.e
      • -Administration Features - Promis.e
        • +Command Protection - Administration Features - Promis.e
        • +Language Database Manager - Administration Features - Promis.e
        • +Mode Manager - Administration Features - Promis.e
        • +Options - Administration Features - Promis.e
        • -Setup - Administration Features - Promis.e
          • Add Catalog Path
          • Catalog Management Tips [FAQ]
          • Catalog Paths
          • Error - "database is used by another user" when creating parts database path
          • Error - Field types do not match and cannot be mapped
          • Error - Title block name is invalid
          • Error creating part database path, DBNETLIB
          • How to Create a new catalog in Bentley Substation and Promis.e
          • Rename a catalog
          • Setup
          • Switch electrical standard used by the software
      • +APIs_VBA - Promis.e
      • +Automation Features - Promis.e
      • +Component Features - Promis.e
      • +Component Management - Promis.e
      • +CONNECT Services - Promis.e
      • +Data Manager - Promis.e
      • +Database Platform Support - Promis.e
      • +Display - Promis.e
      • +Drawing Management - Promis.e
      • +Engineering Design Considerations - Promis.e
      • Error - Object reference...General
      • +Find_Replace - Promis.e
      • Finding the Tutorial
      • +Installation_Configuration - Promis.e
      • +Interoperability - Promis.e
      • +Licensing - Promis.e
      • +Maintenance Features - Promis.e
      • +Migration - Promis.e
      • +OS Support - Promis.e
      • +Panel Layout - Promis.e
      • +Performance - Promis.e
      • +PowerPlatform Support - Promis.e
      • +Print_Publish Features - Promis.e
      • +Project Management - Promis.e
      • +ProjectWise Integration - Promis.e
      • Promis.e Help file
      • +Reports_Output Features - Promis.e
      • +Template Management - Promis.e
      • +Text Tools - Promis.e
      • Training FAQs
      • +Wire Numbering - Promis.e
      • +Wiring Features - Promis.e

     
     Questions about this article, topic, or product? Click here. 

    Error - Title block name is invalid

      Product(s): Promis.e, Bentley Substation
      Version(s): through 08.11.13.140
      Environment: N/A
      Area: Administration Features
      Subarea: Setup

    Error or Warning Message

    "Title block name is invalid" message appears when modifying or creating a new page.

    Explanation

    This message means that the title block specified on the New Page or Modify Page dialog was not found in any of the currently "loaded" catalogs.

    Note that the Title Block drop-down list is a "recently used" list and may contain title blocks that are no longer available.

    How to Avoid

    Add the catalog containing the desired title block to the Catalog Paths area of the promis-e Setup dialog. 

    Title blocks supplied with the software, such as those used in the tutorials, are contained in the JIC-3 (formerly the ANSI-IEEE catalog) and the IEC 2.1 catalog.  These catalogs are installed by default in the following folders:

    • \promis-e Data\Catalogs folder when using Promis.e.
    • \Substation Data\Catalogs folder when using Bentley Substation.

    If the catalog containing the title block is already loaded, eliminate spelling errors and obsolete names by browsing for the title block using the ellipsis button [...] instead of typing the name into the dialog or using the drop-down list.

    If only one title block is listed on the Select Title Block dialog, remove the text from the Name field to clear the automatic filtering and display all the title blocks available in the active catalog paths.

    See Also

    Add Catalog Path

      Original Author:  Matt_P
    • Modify Page
    • Setup
    • new page
    • promis.e
    • error message
    • Bentley Substation
    • en
    • Project Management
    • Administration Features
    • Share
    • History
    • More
    • Cancel
    • Matt_P Created by Communities MVP Matt_P
    • When: Fri, Jun 24 2011 5:44 PM
    • Matt_P Last revision by Communities MVP Matt_P
    • When: Fri, Mar 16 2018 1:33 PM
    • Revisions: 10
    • Comments: 0
    Anonymous
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • User Management
    • Licensing Manager
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2019 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies