• Defining wells in axisymmetric model

    I am trying to dewater inside 15m diameter shaft using axisymmetric model. 10 wells will set up along the bottom of slurry wall. Discharge volume for each well is 0.1m^3/s. So define well parameters with 10*q/(2pi*15m) in Plaxis 2D axisymmetric by following…
  • Extraction using wells

    Greeting for everyone, I am modeling an extraction well (using well element and GW boundary). I use Plaxis 2D and 3D with flow only (transient groundwater). However, when I compare with the analytical method (Jacob and Thiems), the result shows…