Structural results are not included in 2D2011.00's generated report


ApplicationPLAXIS 2D
Issue statusOpen
First Affected VersionPLAXIS 2D 2011.00
Found in VersionPLAXIS 2D 2011.00
Fixed and Released in Version
Issue #16437
Date created19 January 2012
Date modified24 October 2016

Problem description

When selecting structural results (e.g. plates) to be included in the report generator of PLAXIS 2D2011.00’s Output program, these may not be included in the report when not using the advanced selection.

Solution

In order to include these structural results, the advanced selection should be activated.

For the easiest selection, the desired options for Structures (step 5 of 8) should just be selected. Then switch on the advanced selection.

The structure views list will show more options, and the selected option from the non-advanced selection will be automatically selected in the advanced selection.

This is now fixed in PLAXIS 2D2011.02