Application | PLAXIS 2D |
Issue status | ✔ Solved |
First Affected Version | PLAXIS 2D 2012.00 |
Found in Version | PLAXIS 2D 2012.00 |
Fixed and Released in Version | PLAXIS 2D AE |
Issue # | 21996 |
Date created | 30 October 2014 |
Date modified | 24 October 2016 |
Point loads placed on top of an embedded pile row in Input are not taken into account during the calculation if the surrounding soil (around the top of the embedded pile row) is deactivated. The problem only occurs when the connection type of the embedded pile row is set to rigid.
A work around for this problem is to set the connection type of the embedded pile row to free.
This issue is solved since PLAXIS 2D AE.