How to activate a dynamic load


ApplicationPLAXIS 2D
VersionPLAXIS 2D
Date created02 December 2019
Date modified02 December 2019

General aspects

In PLAXIS 2D and 3D, providing that the dynamic module is available, a dynamic (i.e., time-dependent) load can be defined by assigning a dynamic multiplier to the dynamic component of a load. As detailed later, the dynamic component of a given load is independent of its static component. 

Definition of a dynamic multiplier 

A dynamic multiplier can be created either in Structures mode or Staged construction mode, by using one of the following strategies: 

A dynamic multiplier can be defined by a harmonic function or by a table of values. For further details on this aspect, please refer to the Reference manual.

Activation of a dynamic load

To apply a dynamic load in a given dynamic phase, the following conditions should be met:

These aspects are illustrated in the figure below for a dynamic load applied in the y-direction in PLAXIS 2D. Please note that, when applying a dynamic load characterised by more than a single cartesian component, the conditions listed above should be met for all components of the load.

how_to_activate_dynamic_load_4

Static and dynamic components of a load

The static component of a given load is independent of its dynamic component. This means that, when both components are active for a given load (e.g., line load, as shown in the figure below), the total load applied to the model is given by the sum of its static (i.e., time-constant) and dynamic (i.e., time-dependent) components. This allows for the application of a different type of loads at a given location. For instance, it is possible to apply the self-weight of a given equipment by using a static load and the vibrations induced by that equipment by using a dynamic load, as exemplified in the Tutorial manual: Dynamic analysis of a generator on an elastic foundation.

Please note that, in the drawing area, the static component of the load is presented in blue, while the dynamic component of the load is presented in green. To ease their visualisation, the toggle corresponding to each one of these components may be activated/deactivated in the Selection explorer. For instance, in the figure below, the visualisation toggle of the load’s static component is deactivated, allowing for the visualisation of the load’s dynamic component (in green).

how_to_activate_dynamic_load_5

how_to_activate_dynamic_load_6

Time evolution of dynamic loading

When a dynamic load is activated in a given dynamic phase, the value of each of its components (e.g., along y-direction) at each instant of dynamic time, t, is given by:

qy(t) = qy,start,ref x multipliery(t)

where qy,start,ref is the reference value of the dynamic component of the load and multipliery(t) is the time-dependent multiplier of the load, defined by a harmonic function or table of values, as mentioned before.

For instance, assuming that, in a 2D analysis, a given y-component of a dynamic load would be defined by a reference value, qy,start,ref, of -2.0 kN/m/m, as well as by a harmonic multiplier characterised by an amplitude of 10.0 kN/m/m, a frequency of 1.0 Hz and a null phase (as shown in the figure below), the dynamic load applied to the model at 0.25 s would be equal to:
qy (t = 0.25 s) = -2.0 x 10.0 x sin(2 p x 0.25) = -2.0 x 10.0 = -20.0 kN/m/m.

how_to_activate_dynamic_load_7

Supposing now that a static loading would also be applied in the y-direction with a uniform distribution and qy,start,ref = -8.0 kN/m/m, the total load applied to the model at 0.25 s would consits of the sum of the static and dynamic values:
qy (t = 0.25 s) = -8.0 – 2.0 x 10.0 x sin(2 p x 0.25) = -28.0 kN/m/m.

See also