Problem with saving rotational soil reaction curves


ApplicationPLAXIS MoDeTo
Issue status Solved
First Affected VersionPLAXIS MoDeTo CONNECT Edition V20
Found in VersionPLAXIS MoDeTo CONNECT Edition V20
Fixed and Released in VersionPLAXIS MoDeTo CONNECT Edition V20 Update 2
Issue #SW-46210
Date created24 February, 2020
Date modified14 May, 2020

Problem description

In PLAXIS MoDeTo CONNECT Edition V20 (release of January 2020), the Save Selection and Save All options generate an empty .TSV file when used with rotational soil reaction curves (moment-rotation and base moment-base rotation).

Solution

This is now fixed in PLAXIS MoDeTo CONNECT Edition V20 Update 2

Workaround for older versions: Choose ‘Copy Selection’ or ‘Copy All’ and then paste the table data to its destination. A TSV file can be created with any plain text editor