<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Modifying field properties: gINT crashes if Field Properties dialog loses focus</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Modifying field properties: gINT crashes if Field Properties dialog loses focus</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus</link><pubDate>Tue, 02 Sep 2014 17:57:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b0b77efe-bb0a-4584-a08a-763c08b0a663</guid><dc:creator>Kathleen Holcomb</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus#comments</comments><description>Current Revision posted to gINT | Keynetix Wiki by Kathleen Holcomb on 9/2/2014 5:57:11 PM&lt;br /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;gINT Logs, gINT Professional, gINT Professional Plus&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.30.03.135&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Data Entry&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kathleen Holcomb, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error Message&lt;/h1&gt;
&lt;p&gt;gINT is crashing each time the &amp;quot;Field Properties&amp;quot; window loses focus with this message:&lt;/p&gt;
&lt;p&gt;&lt;code&gt;Run-time error &amp;#39;0&amp;#39;&lt;/code&gt;&lt;/p&gt;
&lt;h1&gt;Explanation:&lt;/h1&gt;
&lt;p&gt;To produce:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;In Input, right click on a field&lt;/li&gt;
&lt;li&gt;Select &amp;quot;Field Properties...:&lt;/li&gt;
&lt;li&gt;Change either the colour or the lookup filter (other fields may also cause the behaviour)&lt;/li&gt;
&lt;li&gt;Click on another program or click on a secondary monitor&lt;/li&gt;
&lt;li&gt;Try to click back on the &amp;quot;Field Properties&amp;quot; window&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The field properties window&amp;nbsp;has disappeared behind the&amp;nbsp;gINT program. It can&amp;#39;t be moved, minimized or resized&amp;nbsp;to get at it nor can&amp;nbsp;Alt+Tab be used to access the window.&lt;/p&gt;
&lt;p&gt;Clicking on &amp;quot;show desktop&amp;quot; or entering the key board short cut &amp;quot;Win+D&amp;quot; and then clicking on gINT in the task bar will return to the &amp;quot;Field properties&amp;quot; dialog, but gINT then crashes with the error message above.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;This problem has been fixed in gINT version 8.30.03.186.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Modifying field properties: gINT crashes if Field Properties dialog loses focus</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus/revision/4</link><pubDate>Fri, 28 Mar 2014 20:22:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b0b77efe-bb0a-4584-a08a-763c08b0a663</guid><dc:creator>Kathleen Holcomb</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus#comments</comments><description>Revision 4 posted to gINT | Keynetix Wiki by Kathleen Holcomb on 3/28/2014 8:22:29 PM&lt;br /&gt;
&lt;p&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;gINT Logs, gINT Professional, gINT Professional Plus&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.30.03.135&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Data Entry&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kathleen Holcomb, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error Message&lt;/h1&gt;
&lt;p&gt;gINT is crashing each time the &amp;quot;Field Properties&amp;quot; window loses focus with this message:&lt;/p&gt;
&lt;p&gt;&lt;code&gt;Run-time error &amp;#39;0&amp;#39;&lt;/code&gt;&lt;/p&gt;
&lt;h1&gt;Explanation:&lt;/h1&gt;
&lt;p&gt;To produce:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;In Input, right click on a field&lt;/li&gt;
&lt;li&gt;Select &amp;quot;Field Properties...:&lt;/li&gt;
&lt;li&gt;Change either the colour or the lookup filter (other fields may also cause the behaviour)&lt;/li&gt;
&lt;li&gt;Click on another program or click on a secondary monitor&lt;/li&gt;
&lt;li&gt;Try to click back on the &amp;quot;Field Properties&amp;quot; window&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The field properties window&amp;nbsp;has disappeared behind the&amp;nbsp;gINT program. It can&amp;#39;t be moved, minimized or resized&amp;nbsp;to get at it nor can&amp;nbsp;Alt+Tab be used to access the window.&lt;/p&gt;
&lt;p&gt;Clicking on &amp;quot;show desktop&amp;quot; or entering the key board short cut &amp;quot;Win+D&amp;quot; and then clicking on gINT in the task bar will return to the &amp;quot;Field properties&amp;quot; dialog, but gINT then crashes with the error message above.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;This problem has been fixed in gINT version 8.30.03.186.&amp;nbsp; Please contact Bentley Technical Support to obtain.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Modifying field properties: gINT crashes if Field Properties dialog loses focus</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus/revision/3</link><pubDate>Mon, 13 Jan 2014 18:14:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b0b77efe-bb0a-4584-a08a-763c08b0a663</guid><dc:creator>Kathleen Holcomb</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus#comments</comments><description>Revision 3 posted to gINT | Keynetix Wiki by Kathleen Holcomb on 1/13/2014 6:14:18 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;gINT Logs, gINT Professional, gINT Professional Plus&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.30.03.135&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Data Entry&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kathleen Holcomb, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error Message&lt;/h1&gt;
&lt;p&gt;gINT is crashing each time the &amp;quot;Field Properties&amp;quot; window loses focus with this message:&lt;/p&gt;
&lt;p&gt;&lt;code&gt;Run-time error &amp;#39;0&amp;#39;&lt;/code&gt;&lt;/p&gt;
&lt;h1&gt;Explanation:&lt;/h1&gt;
&lt;p&gt;To produce:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;In Input, right click on a field&lt;/li&gt;
&lt;li&gt;Select &amp;quot;Field Properties...:&lt;/li&gt;
&lt;li&gt;Change either the colour or the lookup filter (other fields may also cause the behaviour)&lt;/li&gt;
&lt;li&gt;Click on another program or click on a secondary monitor&lt;/li&gt;
&lt;li&gt;Try to click back on the &amp;quot;Field Properties&amp;quot; window&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The field properties window&amp;nbsp;has disappeared behind the&amp;nbsp;gINT program. It can&amp;#39;t be moved, minimized or resized&amp;nbsp;to get at it nor can&amp;nbsp;Alt+Tab be used to access the window.&lt;/p&gt;
&lt;p&gt;Clicking on &amp;quot;show desktop&amp;quot; or entering the key board short cut &amp;quot;Win+D&amp;quot; and then clicking on gINT in the task bar will return to the &amp;quot;Field properties&amp;quot; dialog, but gINT then crashes with the error message above.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;This problem has been fixed in gINT version 8.30.03.186.&amp;nbsp; Please contact Bentley Technical Support to obtain.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Modifying field properties: gINT crashes if Field Properties dialog loses focus</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus/revision/2</link><pubDate>Mon, 13 Jan 2014 18:12:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b0b77efe-bb0a-4584-a08a-763c08b0a663</guid><dc:creator>Kathleen Holcomb</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus#comments</comments><description>Revision 2 posted to gINT | Keynetix Wiki by Kathleen Holcomb on 1/13/2014 6:12:03 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;gINT Logs, gINT Professional, gINT Professional Plus&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.30.03.135&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Data Entry&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kathleen Holcomb, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error Message&lt;/h1&gt;
&lt;p&gt;gINT is crashing each time the &amp;quot;Field Properties&amp;quot; window loses focus with this message:&lt;/p&gt;
&lt;p&gt;&lt;code&gt;Run-time error &amp;#39;0&amp;#39;&lt;code&gt;&lt;/code&gt;&lt;/code&gt;&lt;/p&gt;
&lt;h1&gt;Explanation:&lt;/h1&gt;
&lt;p&gt;To produce:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;In Input, right click on a field&lt;/li&gt;
&lt;li&gt;Select &amp;quot;Field Properties...:&lt;/li&gt;
&lt;li&gt;Change either the colour or the lookup filter (other fields may also cause the behaviour)&lt;/li&gt;
&lt;li&gt;Click on another program or click on a secondary monitor&lt;/li&gt;
&lt;li&gt;Try to click back on the &amp;quot;Field Properties&amp;quot; window&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;The field properties window&amp;nbsp;has disappeared behind the&amp;nbsp;gINT program. It can&amp;#39;t be moved, minimized or resized&amp;nbsp;to get at it nor can&amp;nbsp;Alt+Tab be used to access the window.&lt;/p&gt;
&lt;p&gt;Clicking on &amp;quot;show desktop&amp;quot; or entering the key board short cut &amp;quot;Win+D&amp;quot; and then clicking on gINT in the task bar will return to the &amp;quot;Field properties&amp;quot; dialog, but gINT then crashes with the error message above.&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;p&gt;This problem has been fixed in gINT version 8.30.03.186.&amp;nbsp; Please contact Bentley Technical Support to obtain.&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>Modifying field properties: gINT crashes if Field Properties dialog loses focus</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus/revision/1</link><pubDate>Mon, 13 Jan 2014 17:49:42 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b0b77efe-bb0a-4584-a08a-763c08b0a663</guid><dc:creator>Kathleen Holcomb</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/11160/modifying-field-properties-gint-crashes-if-field-properties-dialog-loses-focus#comments</comments><description>Revision 1 posted to gINT | Keynetix Wiki by Kathleen Holcomb on 1/13/2014 5:49:42 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;gINT Logs, gINT Professional, gINT Professional Plus&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.30.03.135&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Data Entry&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kathleen Holcomb, Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;&amp;nbsp;&lt;/h1&gt;
&lt;h1&gt;Error Message&lt;/h1&gt;
&lt;p&gt;gINT is crashing each time the &amp;quot;Field Properties&amp;quot; window loses focus with this message:&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:courier new,courier;"&gt;Run-time error &amp;#39;0&amp;#39;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:courier new,courier;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Explanation&lt;/h1&gt;
&lt;p&gt;XXXXXXX(Provide a detailed explanation of the error message.)XXXXXXX&lt;/p&gt;
&lt;h1&gt;How to Avoid&lt;/h1&gt;
&lt;h3&gt;Option 1 XXXX(Delete this&amp;nbsp;heading if only one option exists.)XXXX&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;
&lt;p&gt;XXXXXXX&lt;/p&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;p&gt;XXXXXXX(add more steps as needed)XXXXXXX&lt;/p&gt;
&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;Option&amp;nbsp;2 XXXX(Delete this&amp;nbsp;section if only one option exists.)XXXX&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;XXXXXXX&lt;/li&gt;
&lt;li&gt;XXXXXXX(add more steps as needed)XXXXXX&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;XXXXXXX(Add links as needed for other relevant Be Communities content.)XXXXXXX&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item></channel></rss>