gINT | Keynetix Wiki How to Define a Calibration Row for Input Sheets and show a Calibration Table
    • Sign In
    • -gINT | Keynetix Wiki
      • +gINT
      • +gINT Collector
      • +gINT Civil Tools
      • -Keynetix
        • +Installing or Upgrading to CONNECT Edition
        • +Archive Webinars
        • +HoleBASE
        • +HoleBASE Civil Extension
        • +HoleBASE Data Entry
        • +HoleBASE Excel Extension
        • +HoleBASE Template Studio
        • +KeyAGS
        • -KeyLAB
          • Implimenting KeyLAB
          • +KeyLAB Setup and Installation
          • +KeyLAB Getting Started Videos
          • +KeyLAB How Tos
          • +Excel Tips and Tricks
          • -KeyLAB FAQ's
            • +Working with Samples
            • +Working with Tests
            • -Test Sheet Design
              • FAQ-How does the 'Engineering Mode' for scaling work
              • How do I hide/remove Test Definitions and Tests which i no longer need?
              • How do I use two input sheets for the same test
              • How Do I Add a Reference Cell?
              • How To Create a Duplicate Test Definition
              • How to Define a Calibration Row for Input Sheets and show a Calibration Table
              • How To Extend List Beyond 100 Rows
              • How To Fix a KeyLAB sheet which isn't showing the correct number of test sheets
              • How To Fix a KeyLAB sheet which isn't showing the correct number of test sheets1
              • How to Fix a Name Range Error
              • How to Fix Lost Test Links
              • How To Fix Problems with Calculation Tabs in KeyLAB
              • How To Link Tests in KeyLAB
              • How to Reference the Schedule Name on a test sheet
              • How to Set Graphing Scales
              • How to Set Printing Settings for consistant margins
              • How To Set up a Grouped Sheet
              • How to set up decimal places and significant figures in KeyLAB.
              • How to set up Image Placeholders
              • How to Use Text Boxes for Headers in KeyLAB
              • How to use the AGS Mapping to Control the Format of the Numeric Values
              • How to use the Geotechnical Function for Graphical Interpretation.
              • How To Use the KeyLAB Validation Cells
              • How To Use the Ordering on Report sheet
              • How To Use the Splitting on Report Sheets
              • Issues Printing Problems
              • Issues With KeyLAB Test Definition and What you Can Put in Them.
              • Issues-Why Do the Graphs not Update when Batch Printing from KeyLAB?
              • One or More Named Ranges contain Invalid References
              • The Geotechnical Functions Addin is not loaded in KeyLAB2
              • There is no Image Path defined in the Preferences dialog
              • Why does my VBA run Slowly within KeyLAB?
            • +Configuration
            • +AGS Management
          • KeyLAB Release Notes
        • +Keynetix Component Downloads
        • +Working from Home with Keynetix Products
        • Hardware Specifications and Recommendations
        • Supported Platforms

     
     Questions about this article, topic, or product? Click here. 

    How to Define a Calibration Row for Input Sheets and show a Calibration Table

      Product(s): Keynetix
      Version(s): 1.0
      Area: Assist

    How to Define a Calibration Row for Input Sheets and show a Calibration Table

    This article discusses how to setup and use a row which reports the calibration information associated with a piece of lab equipment used for testing.

    Firstly, ensure that devices have been setup (and calibration details recorded) under Configuration | Equipment:

    Note that will be necessary to define the 'Constant' (e.g. "a", "b" or "c" in the example above) or the required parameters for the 'Curve' on the input sheet template, so make a note of these if necessary.

    With equipment defined and calibrated the input sheet can be adjusted to report the values. Go to Sheets, select the required Test Definition and sheet (or create a new sheet) and Open:

    Ensure the sheet includes 'Data Cells' to allow the user to define the device used and the date of the test:

    These will be used as a reference to report the correct calibration information. Next, select the cell required for the start of the Calibration Row, this being applied from the Design | Insert menu:

    The row upon which calibration data is reported is then inserted:

    It may be useful to create header labels for these cells by coping and pasting them immediately above:

    If using this technique, the label cells can be differentiated from the calibration row cells as the latter has an array name, rather than just a cell name (compare the top left corner of the two images above). Adjust the cells within Excel as necessary to make them cosmetically pleasing. The cells on the calibration row will then need further definition to identify the correct device and so report calibration information. Use formulas to pull the Test Date and the Device ID (i.e. the cells highlighed in yellow below) from the reference cells created earlier:

    Note that it advisable to apply 'Date' formatting both the 'Test Date' reference and calibration cells.

    Specify the correct Device Type, whether Constant/Curve is required and nominate the required Parameter (i.e. the data noted from the Equipment Manager above):

    Note that in the above example the Curve Parameter is unused - this can simply be Hidden using Excel without ill effect. If a 'Curve' is specfied the name of the required axis (i.e. that reported as the Result) should be specified as the required Parameter. A point on the other axis should then be nominated as the Curve Parameter:

    So, in the example immediately above the reported Result will be the "Mass" recorded at the point where "20" occurs on the other axis in the curve.

    If necessary, multiple calibration rows can be inserted into a sheet to report different constants or points along the axis of the graph.

    KeyLAB | Design | Close and save the changes to the sheet. When the sheet is then used for testing in the lab the calibration row will appear similar to the state in which it was saved in when designed...

    ...but will update with the relevant values when the Device ID and Test Date have been specified in the green reference cells:

    As the values have been specified in the image immediately above note how the Result calibration cell has now updated.

    Note that the calibration row will not update if the Test Date set to a point in time before the first calibration took place.

    Calibration Table

    The Calibration Tables feature will collect all the information in the calibration curve results.

    To obtain the curve table you are required to fill in the calibration row, as for the other type of calibration information only change the constant/curve to CurveTable. The result is used as the cell location where the table will be placed.

    The date format has to be UK Short date format. 

    • Migrated
    • Share
    • History
    • More
    • Cancel
    • wiki.author Created by Bentley Colleague wiki.author
    • When: Tue, Jun 9 2020 9:46 PM
    • Oliver Carnaby Last revision by Bentley Colleague Oliver Carnaby
    • When: Thu, Jun 30 2022 4:35 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies