<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>gINT Startup Issue: The operating system is not presently configured to run this application</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>gINT Startup Issue: The operating system is not presently configured to run this application</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application</link><pubDate>Fri, 06 Aug 2021 01:13:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9dad6f9f-1afc-444d-b4c0-97f3d69ff934</guid><dc:creator>Kirk Johnson</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application#comments</comments><description>Current Revision posted to gINT | Keynetix Wiki by Kirk Johnson on 8/6/2021 1:13:26 AM&lt;br /&gt;
&lt;p&gt;If you have recently&amp;nbsp;had gINT not open&amp;nbsp;with an error about the operating system,&amp;nbsp;&amp;nbsp;this is most likely an issue with the Microsoft Access database engine.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/gINT-error.png" /&gt;&lt;/p&gt;
&lt;p&gt;This Microsoft update causes an issue with the Microsoft Access Database engine 32-bit that gINT requires.&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Two Options to Repair the Access Database engine 32-bit&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;1.Goto control panel programs.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Find the Microsoft Access database engine&amp;hellip; Select it and run repair&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/pastedimage1628004142775v1.png" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&amp;nbsp;If Option 1 does not resolve then try option 2.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;2. Let gINT Reinstall the Access Database engine 32-bit&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;First make sure there are not any gINT processes running in task manager. If so end them.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then uninstall gINT and &amp;nbsp;also uninstall the access 2010 redistrib 32 bit from control panel. If you have 2 redistributables , the smaller one is usually the 32 bit one.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;You will probably need to reboot. After reboot reinstall gINT. It should prompt the install of the prerequisite Access 2010 redistrib 32 bit&amp;hellip;. let the program reinstall it.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then you may be prompted to reboot again after install.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then reopen gINT.&lt;/p&gt;
&lt;p&gt;Below shows the Access Database engine in control Panel&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/pastedimage1628004142776v2.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>gINT Startup Issue: The operating system is not presently configured to run this application</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application/revision/2</link><pubDate>Fri, 06 Aug 2021 01:10:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9dad6f9f-1afc-444d-b4c0-97f3d69ff934</guid><dc:creator>Kirk Johnson</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application#comments</comments><description>Revision 2 posted to gINT | Keynetix Wiki by Kirk Johnson on 8/6/2021 1:10:11 AM&lt;br /&gt;
&lt;p&gt;If you have recently&amp;nbsp;had gINT not open&amp;nbsp;with an error about the operating system,&amp;nbsp;&amp;nbsp;this is most likely an issue with the Microsoft Access database engine.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/gINT-error.png" /&gt;&lt;/p&gt;
&lt;p&gt;This Microsoft update causes an issue with the Microsoft Access Database engine 32-bit that gINT requires.&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Two Options to Reinstall the Access Database engine 32-bit&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;1.Goto control panel programs.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Find the Microsoft Access database engine&amp;hellip; Select it and run repair&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/pastedimage1628004142775v1.png" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&amp;nbsp;If Option 1 does not resolve then try option 2.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;2. Let gINT Reinstall the Access Database engine 32-bit&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;First make sure there are not any gINT processes running in task manager. If so end them.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then uninstall gINT and &amp;nbsp;also uninstall the access 2010 redistrib 32 bit from control panel. If you have 2 redistributables , the smaller one is usually the 32 bit one.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;You will probably need to reboot. After reboot reinstall gINT. It should prompt the install of the prerequisite Access 2010 redistrib 32 bit&amp;hellip;. let the program reinstall it.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then you may be prompted to reboot again after install.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then reopen gINT.&lt;/p&gt;
&lt;p&gt;Below shows the Access Database engine in control Panel&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/pastedimage1628004142776v2.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>gINT Startup Issue: The operating system is not presently configured to run this application</title><link>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application/revision/1</link><pubDate>Tue, 03 Aug 2021 15:26:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:9dad6f9f-1afc-444d-b4c0-97f3d69ff934</guid><dc:creator>Kirk Johnson</dc:creator><comments>https://communities.bentley.com/products/geotechnical1/w/wiki/55623/gint-startup-issue-the-operating-system-is-not-presently-configured-to-run-this-application#comments</comments><description>Revision 1 posted to gINT | Keynetix Wiki by Kirk Johnson on 8/3/2021 3:26:02 PM&lt;br /&gt;
&lt;p&gt;If you have recently&amp;nbsp;had gINT not open&amp;nbsp;with an error about the operating system,&amp;nbsp;&amp;nbsp;this is most likely an issue with the Microsoft Access database engine.&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/gINT-error.png" /&gt;&lt;/p&gt;
&lt;p&gt;This Microsoft update causes an issue with the Microsoft Access Database engine 32-bit that gINT requires.&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Two Options to Reinstall the Access Database engine 32-bit&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;1.Goto control panel programs.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Find the Microsoft Access database engine&amp;hellip; Select it and run repair&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/pastedimage1628004142775v1.png" alt=" " /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;2. Let gINT Reinstall the Access Database engine 32-bit&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;First make sure there are not any gINT processes running in task manager. If so end them.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then uninstall gINT and &amp;nbsp;also uninstall the access 2010 redistrib 32 bit from control panel. If you have 2 redistributables , the smaller one is usually the 32 bit one.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;You will probably need to reboot. After reboot reinstall gINT. It should prompt the install of the prerequisite Access 2010 redistrib 32 bit&amp;hellip;. let the program reinstall it.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then you may be prompted to reboot again after install.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Then reopen gINT.&lt;/p&gt;
&lt;p&gt;Below shows the Access Database engine in control Panel&lt;/p&gt;
&lt;p&gt;&lt;img src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-01-05/pastedimage1628004142776v2.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;