I get a red user notification that says, "Inlet guttter mannings n should be greater than 0".

   
  Applies To 
   
  Product(s): Bentley StormCAD
  Version(s): 08.11.03.83
  Environment:  N/A
  Area:  Output and Reporting
  Subarea: 
  Original Author: Mark Pachlhofer, Bentley Technical Support Group
   

 

 

 

 

 

 

 

Problem Description

I get a red user notification that says, "Inlet guttter mannings n should be greater than 0". How can I fix this problem?

Steps to Resolve

Make all your catch basins "On Grade" temporarily

  1. Global edit all your catch basins that are set to an inlet location of "In Sag" to be "On Grade".

  2. Set the "Mannings N (Inlet)' value to something greater than 0.00

  3. Global edit all your catch basins back to "In Sag"

  4. Run your model

 

Recommended