You are currently reviewing an older revision of this page.
Introduction
The new element which is introduced with the release of SS4 is headwall. This technote explains about general structure of headwall as an element.
The Headwalls are generally concrete or masonry retaining walls, which are placed at outlet side of a drain or culvert. Headwalls should be designed as such by considering factors such as earth pressure, loading and soil properties.
The Headwall element has been added in SS4 in order to support Subsurface Utilities Project allowing users to directly analyze and design these structural elements without having to insert inlet and/or cross-section elements as proxy hydraulic elements. The Headwall element is available for modeling in the layout toolbar as shown below.
Headwall node within the Standalone Layout Toolbar
A headwall node that is the Start Node to a conduit will be drawn in mirror image to Headwall node that is a Stop Node. A Headwall can only be designed for a closed conduit & only a Conduit link can be used to model a Culvert. It is not possible to connect two conduit links with a headwall node during layout.
By hydraulic convention, culvert entrances usually have end-treatments that correspond to headwalls at the entrance and endwalls at the outlet. But we will refer to all end treatments, regardless on upstream or downstream location or structural aspect as Headwalls.
While setting up the headwall in the model you need to define the referenced culvert in the properties of the headwall as seen below.
A conduit that is declared to be a culvert link may have a Headwall node at either end. Conduit can be set as Culvert by changing Is Culvert? to True in the properties of the conduit.
You may model projected or mitered end treatments on culvert link with connection to a cross section or outfall node. Different possible combinations of headwalls can be seen below. If you attempt a configuration that is not permissible, you will get user notification for that.
More Valid Configurations: Culvert with channel links.
Some Invalid Configurations, yet possible to layout. User notifications expected
Headwall Property Grid: Basic Attributes
The following attributes of a Headwall node are visible in the Headwall property grid.
Headwall Property Grid
Culverts in SS3 & in SS4
Culverts in SS3 used to be designed using a cross section node at the end. Culvert inlet coefficients could be specified through conduit properties. But with release of SS4 headwalls can be designed for the culvert at one end or at both the ends. Comparison can be seen in the screenshot below.
Culverts in SS3 & Culverts in SS4
The Headwalls are the end treatments of the culverts. If you need to model headwall then there has to be an adjacent culvert for that. So define is Culvert to True in the properties of the conduit & then upstream & downstream headwalls in the physical properties of culvert (see screenshot above).
Culvert inlet Coefficients:
In previous software releases you could reference an entrance loss and other Form 1 and 2 coefficients by selecting a Culvert Inlet Coefficient Engineering Library data instance through the Conduit Property Grid as seen below.
Selection of Culvert Library Data from Conduit Property Grid in Bentley SewerGEMS SS3.
Starting with SS4, element manager called Culvert Inlet Coefficients dialog is accessible from the Components menu, appearing just after Conduit Catalog. The manager dialog is similar to Conduit Catalog manager, including sync capabilities to the Culvert Inlet Coefficients type of engineering library data. The headwall section properties can be set through the headwall property grid & as well as the conduit property grid.
The Culvert Inlet Coefficients manager dialog has two label columns: Label and Barrel Shape.
Mock-up of Culvert Inlet Coefficients dialog.
All the attributes of Culvert Inlet Coefficients engineering library data are mirrored and made available for editing in the right side of the dialog.
From a Headwall Property Grid, you can reference from the Culvert Inlet Coefficient Manager by selecting […] from Inlet Description. This function is similar to selecting a Conduit Catalog reference. A non-editable preview of referenced support element data values is displayed in the corresponding fields in the Headwall Property Grid.
Conduit Property Grid & Headwall Property Grid in SS4.
The Culvert Barrel Shape field reflects a read-only value of the downstream conduit’s shape if the Headwall node is a Start Node. It reflects value of the upstream conduit shape if it is a Stop Node.
The read-only Is Inlet? attribute is True if the Headwall node is a Start Node. It will be False if Headwall node is the connected downstream node of the culvert link.
Boundary types of Headwall
Headwall with no upstream connections- Inlet
A Headwall node can be the most upstream node in a gravity sub-network, similar to other gravity network nodes. In this case, a derived result field Boundary Type will have value of Inlet. This value is presented in Headwall property grid when it detects there is no incoming link.
The default value of this attribute is Intermediate, if headwall is an intermediate element in the model.
When the node has a state of Inlet or Outlet, the Cross Section related attributes are visible in the property grid but they will not be validated, you will get a user notification – Cross section dimensions are ignored. Conduit attributes are used instead.
Headwall with no downstream connections – Free Outfall
A Headwall node can be the terminal point of a gravity sub-network, in place of an outfall element. In this case, a derived result field Network Boundary Type has value of Outlet. This value is presented in Headwall property grid when it detects there is no outflow link.
Headwall as an alternative to a Pond Outlet Structure
In previous releases, only the Pond Outlet Structure node modeled the downstream connections in the network from a pond. But you may now model the Pond outflow through a headwall node and culvert link.
When headwall node is not a stop node (the headwall node has no incoming channel or conduit link),
When a headwall node is at an upstream end of the network with no upstream elements, then the upstream pond can be connected to headwall which will act as Pond outlet structure if required.
A dashed line connected to pond will be drawn, with the same behaviour as a Pond Outlet Structure node. In this configuration, the Boundary Type is set to Pond Outlet.
Valid configuration: Headwall instead of a Pond Outlet Structure.
Headwall empties to a Pond
If headwall node has no outgoing link, then user can select the Boundary Element option so the Boundary Element field can be used from the Headwall property grid to select a neighboring downstream pond. This mimics the function of an Outfall to Pond connection. In this configuration, the Boundary Type is set to Pond Inlet.
Property grid state for Headwall when selecting a Pond as a Boundary Element.
Valid configuration: Headwall empties to a Pond.
Profile View:
The Headwall element can be seen in the profile view as below, wherein drop in the HGL is seen in the conduit.
Limitations of Headwall:
At a headwall node you cannot have:
Sample File
You can download the sample file of Headwall model from the below mentioned link.
http://communities.bentley.com/products/hydraulics___hydrology/m/hydraulics_and_hydrology_gallery/270016.aspx