| Applies To | | |
| Product(s): | FlowMaster | |
| Version(s): | 08.11.01.03 | |
| Area: | Installation | |
| Original Author: | Mark Pachlhofer, Bentley Technical Support Group | |
Problem Description
When opening FlowMaster V8i SelectSeries 1 the software appears to open, but just hangs and needs to be closed using the task manager.
This issue is primarily seen when using Windows 8 operating system. When FlowMaster is opened using Windows 8 a message may display stating "An internal software error has occurred" as shown below.
Reason
This issue may be related to a corruption in the engineering libraries.
Steps to Resolve
Option 1: Simpler Way
- Navigate to this location:
- Windows XP: C:\Documents and Settings\<user name>\Application Data\Bentley\EngineeringLibraries\
- Windows 7, 8 or 10: C:\Users\<user name>\AppData\Roaming\Bentley\
- Rename the "EngineeringLibraries" folder to something different like "EngineeringLibraries_old".
- Open FlowMaster
Option 2: "Cleaner" Way
- Navigate to this location:
- Windows XP: C:\Documents and Settings\<user name>\Application Data\Bentley\EngineeringLibraries\
- Windows 7, 8 or 10: C:\Users\<user name>\AppData\Roaming\Bentley\
- Delete the EngineeringLibraries.mdb and any .bak or backup files for this database file.
- Open FlowMaster
If the error is still generated, replace the existing engineeringlibraries.mdb file with one found here:
https://communities.bentley.com/products/hydraulics___hydrology/m/hydraulics_and_hydrology_gallery/273291