How do I find the Total Dynamic Head (TDH)?


Product(s):Bentley WaterGEMS, SewerCAD, WaterCAD, SewerGEMS, CivilStorm
Version(s):08.XX.XX.XX,  10.XX.XX.XX
Area:Calculations

Problem

How can I find the Total Dynamic Head (TDH) of one or more pumps?

Problem ID#: 90398

Solution

The Total Dynamic Head is basically the pump head - the head that the pump adds which overcomes both the "static head" (difference in upstream/downstream boundary conditions) as well as the "dynamic head" which is the headlosses in the pipes between.

If you are looking for just the dynamic portion, you would have to find the difference in elevation between the upstream and downstream boundaries (wet well, outfall, etc.), then subtract that from the total pump head.

See Also

Understanding System Head Curves in WaterGEMS, WaterCAD, and SewerCAD 

System head curve changing depending on status of other pumps