Flushing alternative option report on minimum pressure

Applies To 
Product(s): WaterGEMS, WaterCAD
Version(s): CONNECT Edition, 08.11.03.17 +
Area:  Results
Original Author: Bentley Technical Support Group

Problem

What will happen when the report on minimum pressure is checked on Flushing alternative window?

What is the purpose of report on minimum pressure?

How do I get the minimum pressure to be reported in the flushing results browser?

Solution

Once report on minimum pressure is checked on flushing alternative window the software will save some information for each flushing event after computing the scenario. You will need to add nodes of interest to the flushing manager in order for the results to be displayed in the flushing results browser.

To get these results, please click on Analysis > Flushing Result Browser. Click on any flushing event and then click on the second button from right (Flushing Event Result). This will bring up a window with the maximum velocity, Minimum pressure and the node where the pressure occurred.

See Also

How are "Pipe sets" and "nodes of interest" used in a flushing analysis to get auxiliary results at other elements?

Flushing in WaterGEMS/CAD Select Series 6+

Flushing in WaterGEMS/CAD Select Series 4-5

Recommended
Related