When opening a .DWG file in the WaterCAD for AutoCAD platform I get an AutoCAD error message that says, "Error handler re-entered. Exiting now."

   
  Applies To 
   
  Product(s):
Bentley WaterGEMS, Bentley SewerGEMS, Bentley CivilStorm, Bentley StormCAD, Bentley PondPack, Bentley SewerCAD, Bentley HAMMER, Bentley WaterCAD
  Version(s): 08.11.XX.XX
  Environment:  N/A
  Area: 
  Original Author: Mark Pachlhofer, Bentley Technical Support Group
   

Problem

When opening a .DWG file in the WaterCAD for AutoCAD platform I get an AutoCAD error message that says, "Error handler re-entered. Exiting now.".

Solution

1) Copy the original files into a new folder minus the .WTG file
2) In Standalone WaterCAD import just the database file (File > Import > WaterCAD Database)
3) Saved the file with the same name as the original after importing it in the new folder.
4) Open the original file along side the newly created file in Standalone and copy over your color codings and annotations from the original model using the copy and paste feature in the element symbology.
5) Saved the new file and opened it again in AutoCAD.