You are currently reviewing an older revision of this page.
Will the minor losses associated with pipe bends be automatically accounted for?
No, you must enter the appropriate minor loss coefficient in the properties of the pipe. A library of typical values for various bend angles are included, which you can choose from.
We have a minor loss engineering library that can be accessed through the "Minor Losses" property in the appropriate element. You'll have to click on the ellipsis button to open an access the minor loss library.
Step 1:
Step 2: