Global edit to conduit "Size" not updating the Size of all conduits

  Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm
  Version(s): 08.11.XX.XX
  Environment: N\A
  Area: Settings/Attributes
  Subarea: N\A

Problem

When performing a global edit on the section size in the conduit flextable, some conduits' section size is not being changed accordingly.


Problem ID#: 55413

Solution

The "Size" field (called "section size" in older versions) is used when the conduit type is set to Catalog Conduit. So, first add the "conduit type" field and make sure the
offending conduits are set to "catalog conduit".

Next, make sure that the "Catalog Class" is set to the same class (or in older versions, make sure the Material is the same). For instance you may have a section size
called "12 inch", whose catalog class is "circular - pvc". If a particular conduit's catalog class is not set to "circular - pvc", you will not be able to use that section size, and therefore the global edit will not be able to change it. After setting the Catalog Class, you can global edit the Material and Size.
 

See Also

Unable to design pipe sizes/inverts when Conduit Type set to User Defined