Problem
Can I customize the annotation table seen at the bottom of the profiles?

Solution
CONNECT Edition (Version 10.00.00.40) and Later
Starting with the CONNECT Edition release, engineering profiles have the option to include an annotation table which is drawn similar to the analysis profile.
The displayed fields and field order can be edited in the engineering profile which makes it more customizable. (for a subset of specific fields)
To toggle the annotation table display, click on the down arrow next to the Chart Settings icon and select "Show Profile Annotation Table" from the dropdown menu.

The annotation table options can be edited by selecting "Profile Annotation Table Options…" from this dropdown menu. This is currently limited to a specific subset of fields.

Starting with the CONNECT Edition Update 1 release (build 10.01.01.04), an option to "Save Annotation Definition Settings as Default" was added to the engineering profile options menu. This option saves the current annotation definition settings as the default to be used when future engineering profiles are created.

V8i (Versions 08.11.XX.XX)
In the V8i versions (08.11.XX.XX) the profile annotation table cannot be customized.
For reporting of results, the Engineering Style profiles should be used. Engineering profiles can be fully customized in terms of annotations. To access engineering profiles, right click on the name of your profile in the profile manager and choose Engineering Profile. For more information, see the Engineering Profile help topic, and the other resources in the "See Also" section below.

[Enhancement # 295583]
See Also
What's new in SewerGEMS CONNECT Edition
Creating User-Defined Profile Settings [TN]