Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenFlows | Water Infrastructure
  • Product Communities
  • More
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki Setting the correct feature level in the Municipal License Administrator
    • Sign in
    • OpenFlows | Water infrastructure Wiki
    • +OpenFlows CivilStorm
    • +OpenFlows CulvertMaster
    • +OpenFlows FLOOD
    • +OpenFlows FlowMaster
    • +OpenFlows HAMMER
    • +OpenFlows PondPack
    • +OpenFlows SewerCAD
    • +OpenFlows SewerGEMS
    • +OpenFlows StormCAD
    • +OpenFlows WaterCAD
    • +OpenFlows WaterGEMS
    • +OpenFlows WaterSight
    • +OpenFlows WaterOPS
    • +OpenFlows SewerOPS
    • +Bentley HEC-PACK
    • +General
    • +Help and Documentation
    • +Installation
    • -Licensing / Activation
      • "Site has not been activated with server name and activation key on this machine, and a checked-out license is not available. Please run the License Tool"
      • Academic book software, licensing and solution guide
      • Benefits of the Subscription Entitlement Service (CONNECT Licensing) for OpenFlows Users
      • How do I perform a clean uninstall and reinstall of the Hydraulic and Hydrology products?
      • How to manually check in a license
      • License usage logging for multiple instances of the same product on a machine
      • Licensing and Activation Troubleshooting for OpenFlows Products - SELECTServer
      • Licensing OpenFlows products - Subscription Entitlement Service (CONNECT Licensing)
      • Licensing OpenFlows | Hydraulics and Hydrology products - SELECTserver
      • Monitoring License Usage - Subscription Entitlement Service (CONNECT Licensing)
      • OpenFlows Product Licensing FAQs and Troubleshooting
      • Product Offline Notification
      • Products are listed multiple times in the Activation Status tab of the License Management Tool
      • Setting the correct feature level in the Municipal License Administrator
      • Setting the Feature Level via command line for one or more Windows accounts
      • Setting the License Feature Level in the Feature Level Selector
      • Sign in problems or "stopped working" error with CONNECTION Client
    • +Integration
    • +Modeling
    • +Layout and Data Input
    • +Calculations
    • +Output and Reporting
    • +Other
    • +OpenFlows Product TechNotes And FAQs
    • Check boxes do not appear in tables such as Control Sets dialog
    • Consuming ContextCapture production files within your hydraulic model
    • Convergence NOT achieved Message when computing StormCAD or SewerCAD model
    • Converting Junctions or Hydrants to Isolation Valves
    • Displaying Shapefile Labels (Text) As a Background
    • Enhancing OpenFlows multi-user workflows with ProjectWise Share
    • Error "System.TypeInitializationException"
    • Error 32768 when opening model while integrated with ProjectWise
    • Errors installing patch set
    • Error when opening PondPack: "Object reference not set to an instance of an object" or "Application has generated an exception that could not be handled."
    • Error when saving or validating: System.AccessViolationException: Attempted to read or write protected memory.
    • File Open Dialog does not appear
    • Flextable Report of Multiple Element Types
    • Get to know OpenFlows CONNECT Edition
    • Get to know WaterGEMS, WaterCAD and HAMMER CONNECT Edition
    • How do I import/export multiple point pump curve pump definitions into a model using ModelBuilder?
    • How do you save backup files, so they save at different times and multiple levels?
    • How does the intermediate geodatabase (.MDB or .GDB) file function with ArcMap and ArcGIS Pro integration?
    • How to Delete Engineering Libraries if you get a message about a Read-only database
    • How to receive alerts on new version availability?
    • How to register DAO360.dll or a dll file?
    • How to search using wild cards on a sqlite type of database
    • How to See Hebrew or Arabic text in a .DXF file that was exported from WaterGEMS/WaterCAD
    • Hydraulic grade discontinuity at steep pipes or across nodes (frontwater analysis)
    • I get a red user notification that says, "Inlet guttter mannings n should be greater than 0".
    • Importing .HLB library files from old product versions into format used in the V8 product versions
    • Importing External Data in Geographic Coordinate Systems
    • Importing storm data and other library information from older versions
    • Changing element symbols in the AutoCAD platform
    • Interchange
    • Locating OpenFlows product error log file
    • Locating OpenFlows Product Version Number and License Information
    • Model backward / forward compatibility
    • Multi-user Workflows
    • Modeling a closed loop system
    • Modeling a flow split (diversion) with the SewerCAD or StormCAD numerical solver
    • Modeling turbine load acceptance plus load rejection
    • Multiple CN numbers for a catchment and multiple catchments with a single outlet node
    • Network Navigator Trace Upstream/Downstream does not return any elements
    • OpenFlows software numerical solver theory
    • Percent Connected Impervious Areas and Percent Unconnected Impervious Areas
    • Performing a hydrosanitary design in WaterGEMS or WaterCAD
    • PondPack user notification: "The composite outlet structure is either not selected or deleted."
    • PondPack: How to perform a critical duration analysis?
    • Pressure pipe vs. conduit between pump and wetwell
    • Print Preview > Fit to Page shows blank page
    • Properties not working when using MicroStation integration with ProjectWise
    • Properties, Flextables, user notifications, or other dialog is missing or will not open in standalone
    • Properties, user notifications, or other tool managers not showing up in Integrated version of AutoCAD
    • Reusing Pump Definitions (Import / Export)
    • Reversing orientation of Pipes and Conduits in Bulk
    • Saving a hydraulic model when using the AutoCAD platform (i.e. integrated)
    • Important License Update for OpenFlows Users
    • Setting the invert elevation for multiple conduits coming into one manhole
    • Simple Controls vs. Logical Controls
    • Sorting and relabeling a flextable based on upstream-downstream order
    • Source of the default Specific Speed for pumps and turbines
    • Step by step procedure for finding the curb length needed to capture 100% of gutter flow in a curb inlet with a continuously depressed gutter with no clogging
    • System.Reflection.TargetInvocationException crash when trying to open the application
    • Test Wiki Page - A1
    • Text, cells/blocks and line styles do not display correctly in a DXF background layer
    • The flow annotation (label) in my WaterGEMS for ArcMap isn't reflecting the value displayed in my Geotable or Flextable
    • The total area in the CN/Area Collection does not equal the total catchment area
    • Time tolerance setting in SCADAConnect Simulator
    • Troubleshooting ArcMap / ArcGIS Integration
    • Turbine Efficiency
    • Understanding Flow (Additional Subsurface) and Flow (Additional Carryover)
    • Upcoming training and release dates for OpenFlows products
    • User notification "Downstream TW out of range..."
    • User notification "Pump exceeds the maximum operating point specified for the pump curve"
    • User Notification - The captured surface flow at this node does not connect a valid subsurface network. The flow is lost from the system.
    • User Notification: "There is an error in the data for this pipe. The associated data is incorrect"
    • User Notification: Cross section maximum elevation is above the maximum headwater elevation
    • User Notifications: "Pump On elevation is not in the range of upstream ...." and "Off elevation of pump is lower than ..."
    • Using batch pipe split to fix nodes that overlay a pipe instead of connecting to it
    • Using PondMaker with different tailwater for each return event
    • Valve "Status (Initial)" Definitions
    • Velocity Calculations and the Average Velocity Methods in SewerCAD and StormCAD
    • Viewing graph data for multiple scenarios
    • Water age results in a pipe are different from the age in the downstream junction
    • Water Loss Management
    • Water quality Analysis during transient events
    • WaterGems Tips
    • What are the limitations of importing/exporting EPANET files?
    • What is the dotted line that is associated with the isolation valves? Can I turn them off?
    • What's new in WaterCAD, WaterGEMS and HAMMER V8i SELECTseries 6 with CONNECT Integration?
    • What's New in WaterOPS CONNECT Edition 2.3 (Build 10.02.03.06)
    • When the user changes the fluid, why doesn't the calculated pump head change?
    • Working From Home With Your OpenFlows Software
    • "An error occurred when trying to calibrate the model"
    • "COM Error Not Documented" when opening OpenFlows product
    • "Default license feature configuration not found. Product features may be limited. Please run the License Administrator."
    • "The Depth-Flow, Depth-Flow (Simulated Variable Speed) and Volume-Flow pump definition types are unsupported"
    • "Unable to assign attribute ... for element because enumeration value ... is not valid."
    • Add custom data to profile with User Data Extensions
    • After computing a model with the SWMM solver, what does the following warning mean: "Maximum depth increased for node CB-XX"?
    • After computing the model, the pump efficiency results are listed as N/A
    • After running loadbuilder I get a message that says "The layer <Layer_Name> could not be opened."
    • At what point does OpenFlows product license usage start when integrated with MicroStation?
    • Background image quality poor on some computers or Crash when opening models with background layers
    • Blocky stepwise pattern is displayed instead of a continous smooth pattern that was entered when using the SWMM engine
    • Can User Data Extensions be shared between elements in a model?
    • Catch basins imported as manholes from LandXML
    • Change in results before turbine load rejection occurs
    • Custom quadrant curve not being recognized
    • Date-time based query not working
    • Default license configuration not retaining setting
    • Do inactive elements count against the license count?
    • Does HAMMER support initially negative pressures?
    • Does the friction method affect local minor loss in pipes?
    • Does WaterGEMS and WaterCAD report pressures as gauge pressure or absolute pressure?
    • Efficiency Curve vs. Wire-to-Water Efficiency Curve
    • Error importing a LandXML file from StormCAD into Civil 3D "A pipe or conduit had an unsupported geometry"
    • Error message when validating model: "Elevation (Relative) values within the Irregular shape definition must be non-negative."
    • Error message: "Unrecognized database format ..." when trying to open model
    • Error Saving: "Custom results path is invalid"
    • Find if pump operates off of the pump curve during an automated fire flow scenario
    • Flow arrows are not included in an exported DGN file when using the Save Symbology option in the MicroStation platform
    • Flow from pump is delayed after pump startup
    • GeoPak - StormCAD errors - GEOPAK runtime environment not found / Error writing GEOPAK/PowerCivil node
    • HEC-22 2nd edition energy loss calculations with the Implicit solver
    • How are "pipe sets" and "nodes of interest" used in a flushing analysis to get auxiliary results at other elements?
    • How can I see the amount of inflow or outflow occuring for a particular surge tank during the transient simulation in HAMMER?
    • How do I filter a column in my flextable using a custom query that retrieves all records with a <None> attribute?
    • How do I know if and when my pond is overtopping and how to quantify it?
    • How do I save my model files when working in the ArcMap or ArcGIS Pro platform?
    • How do the channel slopes and velocity effect the headloss formulas in SewerCAD and StormCAD?
    • How does StormCAD handle gutter flow from an active catch basin to an inactive catch basin?
    • How does the diameter of an isolation valve effect the calculated results?
    • How to add comments on custom pump and turbine quadrant curves
    • How to find volume of water coming from a trace element?
    • How to open a .PRNX report file created on exporting custom report in OpenFlows product
    • Hydropneumatic tank atmospheric pressure not changing results
    • Hydropneumatic tank profile animation and time history shows zero gas volume
    • Initial surge when using turbine load acceptance operating case
    • Initial turbine HGL the same as the final HGL after load acceptance
    • Irregular Weir Flow Calculations in a Composite Outlet Structure
    • Is it possible to create old PondPack style text reports?
    • Is it possible to have a storm event start at a different time than the model simulation?
    • Is it possible to use point cloud information to populate elevations in Terrain Extractor (TRex)?
    • Is there a recommended level of Skelebration for different modeling conditions?
    • Junctions are created on top of one another after using ModelBuilder with the GIS-ID property
    • Learning Resource Guide for WaterSight
    • License usage in the ArcMap and ArcGIS Pro platform
    • LoadBuilder applying demands or loads to inactive elements
    • LoadBuilder importing zero flow loads
    • Long time to load background layers
    • Manage Pump Speed Series
    • Manage Pump Time Series
    • Managing large number of scenarios
    • Missing Young's Modulus and Poisson's Ratio values in the material library
    • Modeling Arch section shapes in SewerGEMS
    • Modeling closed or pressurized pipes in PondPack
    • Modeling treatment for pollutants at nodes or ponds in SewerGEMS and CivilStorm
    • MrSid files are not available as a background layer type or an error is generated when loading MrSid files
    • +OpenFlows Academic Books
    • Pipe Renewal Planner Vs OpenFlows WaterCAP
    • Pipes connecting to the wrong element after submodel import
    • Pipes not merging when using Skelebrator with series pipe merging
    • PondPack error: Unable to open user roster
    • Problems opening GEOPAK Drainage file exported from StormCAD
    • Query, alert or formula UDX not working correctly with "=" (equals)
    • SCADAConnect in SewerGEMS
    • SCADAConnect Simulator in WaterCAD and WaterGEMS V8i SELECTseries 5
    • Series Pipe Merging in Skelebrator not working for pipes with zero diameter
    • Small difference in gutter worksheet result between US and SI units
    • The concentration at the stop node directly after a constituent source in a tank is decreasing rapidly
    • The control symbol, check valve symbol, and dashed lines connecting customer meters, isolation valves, and SCADA elements are not visible in the ArcMap or ArcGIS Pro platforms
    • The headloss in a pipe downstream of a parallel VSP is higher than expected
    • The result field "Depth (Flooding)" is listed as N/A after computing a model with the SWMM engine. Is there a way to see the depth of flooding for a node?
    • Translated version still showing as English
    • Troubleshooting making a SCADA connection to Oracle database
    • Troubleshooting ModelBuilder issues and errors connecting to an Oracle database
    • User Data Extension not appearing in the Post-Calculation Processor's "Output Property" field
    • User Data Extensions in the Fireflow report
    • User Notification "More than one VSPB cannot control the same control node"
    • User notification when computing: IDF data is not supported by SWMM. Storm event is excluded from export.
    • User notification: "Conduit has a Stop control structure, but this is not supported next to the connected outfall element."
    • User notification: "Transition from CONCENTRATED to EXTENDED"
    • Using Imperial and Metric Hydro International Vortex Valves
    • Using US Survey feet
    • Warning about outlet hydrograph not cresting
    • WaterGEMS and WaterCAD Data Import FAQ
    • WaterSight - Pump Overview
    • What can I do to speed it up a file I need to extract elevations from is taking a long time to process in TRex?
    • What does Entrance Control mean?
    • What is the best way to model an orifice plate inside a catchbasin with surface storage above the catchbasin rim?
    • What is the difference between a stand pipe and an inlet box?
    • What is the purpose the Rainfall File, Runoff File, and RDII File in the Calculations Options?
    • What is the workflow for setting up pre and postdeveloped conditions for multiple return events?
    • What kind of demands should be used as the initial conditions of a transient simulation?
    • What's new in HAMMER V8i SELECTseries 6?
    • When running a query, why is it not picking up the elements that it should?
    • Why are there 2 entries for the same alternative in the dropdown menu in the properties of a scenario? One with an "i" and one without it.
    • Why are there so many extra element types listed for WaterGEMS and WaterCAD, such as surge tank, rupture disk, Periodic head-flow?
    • Why do I get a warning message about the rational method being used for the modified rational method?
    • Will SCADA Results Publishing work with only OPC sources?

    You are currently reviewing an older revision of this page.

    • History View current version

    Setting the correct feature level in the Municipal License Administrator

      Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD
      Version(s): 08.11.XX.XX, 10.XX.XX.XX
      Area: Licensing

    Problem/Symptom

    1) How can I properly configure the program to use an appropriate feature level (pipes, inlets, ponds, AutoCAD/Standalone, etc) based on the needs of my particular project and on what I am licensed for? (to avoid accidental overage / QTL)

    2) I've received an unintended overage and need to know how to properly set the feature level at the end user to avoid it in the future.

    3) I'm getting a message when computing my model that I've exceeded the number of registered pipes / inlets / ponds but I don't have more than what I'm licensed for.

    4) When trying to open the program in AutoCAD mode, I'm getting a message that there is "no valid <product name> for AutoCAD license..."

    5) I'm seeing multiple licenses show up in the Activation status tab of the License Management Tool, some say expired. Is this a problem?

    Solution

    For a video demonstration, see further below.

    The Haestad products (with the exception of FlowMaster and CulvertMaster) use the concept of Feature Levels for licensing. The product can be purchased and/or licensed differently depending on the number of allowable elements in the model. For example, WaterCAD has a pipe limit, such as 2000 pipes, and can also be purchased with or without AutoCAD integration.

    Since there is a possibility of having multiple available feature configurations for the same product, a tool called the Municipal License Administrator (MLA) must be used on the client computer to select which one the program will use (and log license usage against). If you do not use this tool or select a feature configuration for your product during installation it will default to the lowest limit. If you're encountering an error about exceeding the limit it may be that the default was not set.

    This concept is especially important for those who are on SELECT OpenAccess, because every possible feature level for every Haestad product will be available to you by default. It is important to understand how to properly set the default feature level and its impact on billing. With SELECT OpenAccess (SOA), the general idea is that you can easily move up to the next feature level when needed (for example if a project expands and the model gets larger) without the need to go through a procurement process and purchase additional licenses. You simply set the feature level and will be billed based on what you use. However, this relies on proper selection of the default feature configuration so as not to accidentally use a feature level that is too high for your needs. See more further below under "What if I don't want to accidently set the wrong feature limit?"

    The Municipal License Administrator (MLA) can be accessed from the product's folder off the Start menu (Start > All Programs, Bentley > Program Name > Municipal License Administrator) or on the home screen via the search tool. Upon opening it available products and their feature configurations should display. If they do not click "Refresh Configurations". Left click the row with the configuration you want to use and click the "Make Default" button. Close the MLA, re-open the product in question and confirm the "Size" under Help > About <Product_Name>

    Warning: license charges may be incurred, so please ensure that the correct feature limit is selected.

    In the above example we can see several feature configurations available for SewerGEMS, StormCAD and WaterCAD. For example, WaterCAD is set to use a 10,000 pipe limit, with the ability to integrate with MicroStation and AutoCAD. Here is the "About" window:

    How do I know which feature level is appropriate?

    The feature level selection is primarily dictated by the maximum number of hydraulic model features (such as pipes) that can be present in the model during calculation. You can always open and work on a model that contains more features than you are licensed for, but you will not be able to compute or print.

    If your company has a SELECT OpenAccess subscription, all feature levels will be available for you to select from. If set your feature level (using the Municipal License Administrator) to the feature level that you own, and there is no other concurrent use of that feature level, then no overage will occur. If you set the feature level to one that you do not own, then it will be included on your quarterly term license (QTL) invoice. So, it is important to be aware of your organization's purchased feature levels. Of course, if the need arises to use a higher feature level, you're always able to do so, and will only be billed for the usage of that higher feature level when you record usage against that feature level.

    Important note: if only one user is expected to be using the software at a given time, it is best to avoid setting the default feature level to one that is below one that you own. For example if you only own a 5000 pipe license of WaterCAD but need to work on a model with only 800 pipes in it, it is still best to set the feature level to 5000 pipes (rather than 1000 pipes), to avoid an overage/QTL invoice on the 1000 pipes feature level that you do not own a license for. However if a second user in your organization needs to work on a larger model (for example 4000 pipes), and anticipates needing to work on it at the same time that you will be working on the 800 pipe model, then it would be best to use the 5000 pipes license for that user, and the 1000 pipes license for the other one, since the QTL/overage of the 1000 pipe license will be less than the QTL/overage of the 5000 pipe license.

    If you are unsure of which feature level to use because the model has not yet been built, you could check the source data that will be imported (shapefile polylines, DXF polylines, spreadsheet, EPANET file, etc) to see the number of features that will be imported.

    Note that the use of Laterals and Customer elements , isolation valves and Skelebrator can assist in reducing the number of pipes in a WaterCAD or WaterGEMS model.

    What if I don't want to accidently set the wrong feature limit?

    This is especially important if you have a SELECT Open Access subscription, which allows access to all products and feature limits.

    In general, you should use the lowest feature limit (and set it to one that you own, if you do own one, as explained above), unless your Site Administrator specifies otherwise. For example, if you know that the maximum number of pipes you will need to use in a given WaterGEMS model is approximately 400, then set your pipe limit to 500. If in doubt, check with your Site Administrator.

    If you manage licenses for your company consider Custom Activation Groups, which allow you to create separate activation keys with only selected products and features available. For more, see "Custom Activation Groups" under the "See Also" section below.

    What if I don't see my product / feature level in the MLA

    First check if the product is checked out. Open the License Management Tool, click the License Checkout tab, and note the list of products at the top. if you see your product/feature listed there but with a zero next to it that means someone has it checked out. If this is the case contact your site administrator for assistance (a site administrator is usually someone the IT department).

    If the product does not display in the list in the License Management Tool (LMT), contact your Site Administrator to ensure that the correct Activation key is being used (as seen under Tools > Options in the LMT). It could be that you're using a custom activation group or ELS feature configuration with the product hidden, or there are access restrictions in place on the server side.

    What if two of the same product appear to be set as default?

    This can happen if you have more than one seat of the license and one of them is checked out. A checked out license will also be forced as default so it will show as an extra line in the MLA. For more information see "Default license configuration not retaining setting" under the "See also" section below.

    What if multiple feature levels display in the Activation Status area of the License Management Tool?

    The activation status area will show a history of all feature levels and products that were attempted to be activated in the past. See more here:

    Products are listed multiple times in the Activation Status tab of the License Management Tool

    If I set the default configuration will it be set for all Windows users on that computer?

    Not necessarily. Depending on the permissions that the Municipal License Administrator (MLA) is opened with and the version of the program, the default feature configuration is either stored in the area of the registry that all users can access, or the area that only the user who set the default can access. See below article for more:

    Setting the Default Feature Configuration as an Administrator, for other Windows Accounts

    What if I need further help?

    Check the other resources below under "See Also" or contact technical support.

    Video Demonstration

    See Also

    Hydraulics and Hydrology Product Licensing (Activation) FAQs and Troubleshooting [TN]

    Performing a silent installation for Bentley's Water and Storm Sewer products

    How can I reduce the number of pipes in my model?

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies