Product(s): |
Bentley PondPack |
|
|
Version(s): |
10.00.016.00 |
|
Problem
User is receiving hydrograph truncation warnings. Why?
Solution
In PondPack a truncation warning simply means the hydrograph does not begin or end on zero flow. So, if you have a base flow, you will get a truncation warning. Another cause of truncation is rooted in the calculation increment. For example, if the increment is too short, the total time period will not cover the full extent of the hydrograph and will not be calculated, therefore it will be truncated on the right side. On the other hand, if the computation increment is too large, the beginning of the hydrograph could be missed and, therefore, start at a point later than the beginning of the hydrograph.
See Also
Warning about outlet hydrograph not cresting solution