<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals</link><pubDate>Tue, 18 Oct 2022 21:09:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Larry Abla</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Current Revision posted to OpenFlows | Water Infrastructure Wiki by Larry Abla on 10/18/2022 9:09:58 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS, SewerCAD&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated&amp;nbsp;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392/modeling-storm-sewer-property-connections"&gt;Property Connection elements&lt;/a&gt; to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element (they are &amp;quot;orphaned&amp;quot;). Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Note&lt;/strong&gt;:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span&gt;Property connections and their attached tap and lateral will be assigned based on the nearest conduit, perpendicularly. If the intersecting point is&amp;nbsp;&lt;/span&gt;&lt;strong&gt;within 10 feet&lt;/strong&gt;&lt;span&gt;&amp;nbsp;of the start or stop node, then that node will be consider as the nearest element and the property connection will be assigned directly to the junction. A common situation would be a cul-de-sac.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Once property connections are attached to conduits via laterals and taps, t&lt;span&gt;he flows from each lateral a&lt;/span&gt;&lt;span&gt;re assumed to enter the network at the upstream end of the&amp;nbsp;&lt;/span&gt;&lt;span&gt;connected&lt;/span&gt;&lt;span&gt;&amp;nbsp;conduit in the GVF-Rational and GVF-Convex solvers, and at the Tap node in the Explicit (SWMM) solver. They are not supported in the Implicit (DW) solver.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, SewerCAD, LoadBuilder, Reviewed2016, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/14</link><pubDate>Tue, 18 Oct 2022 20:38:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Larry Abla</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 14 posted to OpenFlows | Water Infrastructure Wiki by Larry Abla on 10/18/2022 8:38:43 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS, SewerCAD&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated&amp;nbsp;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392/modeling-storm-sewer-property-connections"&gt;Property Connection elements&lt;/a&gt; to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element (they are &amp;quot;orphaned&amp;quot;). Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Note&lt;/strong&gt;:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span&gt;Property connections and their attached tap and lateral will be assigned based on the nearest conduit, perpendicularly. If the intersecting point is&amp;nbsp;&lt;/span&gt;&lt;strong&gt;within 10 feet&lt;/strong&gt;&lt;span&gt;&amp;nbsp;of the start or stop node, then that node will be consider as the nearest element and the property connection will be assigned directly to the junction. A common situation would be a cul-de-sac.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Once property connections are attached to conduits via laterals and taps, t&lt;span&gt;he flows from each lateral a&lt;/span&gt;&lt;span&gt;re assumed to enter the network at the upstream end of the&amp;nbsp;&lt;/span&gt;&lt;span&gt;connected&lt;/span&gt;&lt;span&gt;&amp;nbsp;conduit in the GVF-Rational and GVF-Convex solvers, and at the Tap node in the Explicit (SWMM) solver. They are not supported in the Implicit (DW) solver.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, SewerCAD, LoadBuilder, Reviewed2016, Property Connection, CivilStorm, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/13</link><pubDate>Mon, 22 Jun 2020 20:28:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Jesse Dringoli</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 13 posted to OpenFlows | Water Infrastructure Wiki by Jesse Dringoli on 6/22/2020 8:28:59 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS, CivilStorm, SewerCAD&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated&amp;nbsp;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392/modeling-storm-sewer-property-connections"&gt;Property Connection elements&lt;/a&gt; to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element (they are &amp;quot;orphaned&amp;quot;). Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Note&lt;/strong&gt;:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span&gt;Property connections and their attached tap and lateral will be assigned based on the nearest conduit, perpendicularly. If the intersecting point is&amp;nbsp;&lt;/span&gt;&lt;strong&gt;within 10 feet&lt;/strong&gt;&lt;span&gt;&amp;nbsp;of the start or stop node, then that node will be consider as the nearest element and the property connection will be assigned directly to the junction. A common situation would be a cul-de-sac.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Once property connections are attached to conduits via laterals and taps, t&lt;span&gt;he flows from each lateral a&lt;/span&gt;&lt;span&gt;re assumed to enter the network at the upstream end of the&amp;nbsp;&lt;/span&gt;&lt;span&gt;connected&lt;/span&gt;&lt;span&gt;&amp;nbsp;conduit in the GVF-Rational and GVF-Convex solvers, and at the Tap node in the Explicit (SWMM) solver. They are not supported in the Implicit (DW) solver.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, SewerCAD, LoadBuilder, Reviewed2016, Property Connection, CivilStorm, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/12</link><pubDate>Thu, 25 Oct 2018 13:29:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Jesse Dringoli</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 12 posted to OpenFlows | Water Infrastructure Wiki by Jesse Dringoli on 10/25/2018 1:29:31 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS, CivilStorm, SewerCAD&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated&amp;nbsp;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392/modeling-storm-sewer-property-connections"&gt;Property Connection elements&lt;/a&gt; to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element (they are &amp;quot;orphaned&amp;quot;). Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;Note: once property connections are attached to conduits via laterals and taps, t&lt;span&gt;he flows from each lateral a&lt;/span&gt;&lt;span&gt;re assumed to enter the network at the upstream end of the&amp;nbsp;&lt;/span&gt;&lt;span&gt;connected&lt;/span&gt;&lt;span&gt;&amp;nbsp;conduit in the GVF-Rational and GVF-Convex solvers, and at the Tap node in the Explicit (SWMM) solver. They are not supported in the Implicit (DW) solver.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, SewerCAD, LoadBuilder, Reviewed2016, Property Connection, CivilStorm, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/11</link><pubDate>Wed, 18 Apr 2018 16:52:02 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Jesse Dringoli</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 11 posted to OpenFlows | Water Infrastructure Wiki by Jesse Dringoli on 4/18/2018 4:52:02 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS, CivilStorm, SewerCAD&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated&amp;nbsp;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392/modeling-storm-sewer-property-connections"&gt;Property Connection elements&lt;/a&gt; to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element (they are &amp;quot;orphaned&amp;quot;). Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, SewerCAD, LoadBuilder, Reviewed2016, Property Connection, CivilStorm, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/10</link><pubDate>Tue, 13 Dec 2016 22:49:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 10 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 12/13/2016 10:49:35 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, Reviewed2016, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/9</link><pubDate>Tue, 13 Dec 2016 22:49:19 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 9 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 12/13/2016 10:49:19 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, Reviewed2016, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/8</link><pubDate>Tue, 13 Dec 2016 22:43:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 8 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 12/13/2016 10:43:08 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/32126.how-to-toggle-tap-node-dashed-line-display"&gt;&lt;span style="color:#000000;"&gt;How to toggle tap node dashed line display&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;WIki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/27222.how-do-taps-and-laterals-work-in-the-storm-and-sewer-products"&gt;&lt;span style="color:#000000;"&gt;How do Taps and Laterals work in the storm and sewer products?&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/7</link><pubDate>Wed, 30 Nov 2016 21:34:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Jesse Dringoli</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 7 posted to OpenFlows | Water Infrastructure Wiki by Jesse Dringoli on 11/30/2016 9:34:12 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this&amp;nbsp;method is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Loadbuilder Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False in Element Symbology.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/6</link><pubDate>Mon, 10 Oct 2016 18:05:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 6 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 10/10/2016 6:05:06 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those elements that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this data source is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Load Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. See the following article to remove the dashed line. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;Wiki: &lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Blog [VID]: &lt;a href="/products/hydraulics___hydrology/b/hydraulics_and_hydrology_blog/archive/2016/10/10/introducing-individual-property-connections-to-your-model"&gt;&lt;span style="color:#0099dc;"&gt;Introducing individual Property Connections to your model&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, assign, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/5</link><pubDate>Fri, 30 Sep 2016 20:01:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>MPachlhofer</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 5 posted to OpenFlows | Water Infrastructure Wiki by MPachlhofer on 9/30/2016 8:01:12 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those elements that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this data source is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Load Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. See the following article to remove the dashed line. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, assign, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element and create taps and laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/4</link><pubDate>Fri, 19 Aug 2016 21:06:22 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 4 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 8/19/2016 9:06:22 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those elements that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this data source is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Load Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. See the following article to remove the dashed line. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link and the nearest node is valid (eg. manhole).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, assign, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element and create taps and laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/3</link><pubDate>Fri, 19 Aug 2016 20:40:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 3 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 8/19/2016 8:40:39 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those elements that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this data source is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Load Manager.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Summary.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" /&gt;&lt;/a&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. See the following article to remove the dashed line. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond, the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, assign, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element and create taps and laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/2</link><pubDate>Fri, 19 Aug 2016 20:38:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 2 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 8/19/2016 8:38:10 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those elements that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this data source is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connections_2D00_Disconnected.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder.PNG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-LoadBuilder_2D00_EnterData.PNG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2.PNG" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer_2D00_ArcMap.PNG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer.PNG" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-Select-a-Layer2_2D00_ArcMap.PNG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Link layer not provided&lt;/li&gt;
&lt;li&gt;Link ID Field not provided&lt;/li&gt;
&lt;li&gt;Property Connection Layer not provided&lt;/li&gt;
&lt;li&gt;Property Connection ID Field not provided&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Property-Connection-_2D00_-There-are-no-results.PNG" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Results2.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Load Manager.&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/Synchronize.png" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/5226.Property-Connections.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC3.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. See the following article to remove the dashed line. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC2.png" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond, the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC4.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC5.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-32/PC.png" alt=" " /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, assign, Property Connection, TAP, lateral&lt;/div&gt;
</description></item><item><title>Using LoadBuilder to assign Property Connections to the nearest element and create taps and laterals</title><link>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals/revision/1</link><pubDate>Fri, 19 Aug 2016 20:14:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1feda77b-0008-4574-be92-5f9ff2468b0c</guid><dc:creator>Craig Calvin</dc:creator><comments>https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30393/using-loadbuilder-to-assign-property-connections-to-the-nearest-element-while-creating-taps-and-or-laterals#comments</comments><description>Revision 1 posted to OpenFlows | Water Infrastructure Wiki by Craig Calvin on 8/19/2016 8:14:20 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;SewerGEMS&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;10.00.00.40 and later&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N\A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Modeling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Introduction&lt;/h3&gt;
&lt;p&gt;LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral connection. Isolated Property Connections are those elements that are not connected to any lateral element. Laterals are automatically placed between the source element and the hydraulic network when using LoadBuilder and selecting Property Connection Load Data as the Available LoadBuilder Method.&amp;nbsp; When this data source is used, it is assumed that that load data is already available in the Property Connection.&lt;/p&gt;
&lt;h3&gt;Steps&lt;/h3&gt;
&lt;p&gt;1. Run the LoadBuilder tool from the Tools tab.&lt;/p&gt;
&lt;p&gt;2. Click the New icon&lt;/p&gt;
&lt;p&gt;3. Select Property Connection Load Data as the Available LoadBuilder Method and click Next.&lt;/p&gt;
&lt;p&gt;4. Optional: Create a selection set containing the links elements (ie. Channel or conduit) that can have taps associated with them.&lt;/p&gt;
&lt;p&gt;5. Optional: Create a selection set containing the Property Connection elements that are to be assigned with Loadbuilder.&lt;/p&gt;
&lt;p&gt;6. Enter all fields on the Property Connection Nearest Link page and then click Next.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Link Layer is clicked, the following dialog displays to select all elements of a particular type or a selection set containing conduits and/or channels.&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Link Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;br /&gt;If Next is pressed without selecting the Link layer, a validation error appears stating &amp;quot;Link Layer not provided&amp;quot;.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Link ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection Layer&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;In standalone, when the [&amp;hellip;] button for Property Connection Layer is clicked, the following dialog displays to select all Property Connection Elements or available selection sets of Property Connection type.&lt;br /&gt;In ArcMap, when the [&amp;hellip;] button for Property Connection Layer is selected, the following dialog displays and allows you to select the available Feature Class layer.&lt;/p&gt;
&lt;h4 style="margin-left:30px;"&gt;Property Connection ID Field&lt;/h4&gt;
&lt;p style="margin-left:30px;"&gt;Specify the source database field that contains the identifying label data.&lt;br /&gt;In standalone, MicroStation and AutoCAD platforms, this field is always &amp;ldquo;ElementID&amp;rdquo;.&lt;br /&gt;In ArcMap, multiple choice are given based on the columns available in the selected FeatureClass Layer.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;If Next is pressed without entering one of these fields, then one of the following errors will display.&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;Link layer not provided&lt;br /&gt;Link ID Field not provided&lt;br /&gt;Property Connection Layer not provided&lt;br /&gt;Property Connection ID Field not provided&lt;br /&gt;Property Connection ID Field&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;If the selected Property Connection Layer doesn&amp;#39;t contain any isolated Property Connection elements, then the following message will display.&lt;br /&gt;&amp;quot;There are no results available for the given input parameters. Please verify your data and try again.&amp;quot;&lt;/p&gt;
&lt;p&gt;7. The Results Preview page contains a list of the nearest elements for each Property Connection. A lateral will be created to connect elements listed in the Property Connection column with the corresponding assigned elements in the Nearest Element column. &lt;br /&gt;Based on the geometric location of a Property Connection, the Nearest Element that it is assigned to could be a link (conduit/channel) or node (catch basin, manhole, transition, cross section or headwall) element type.&lt;/p&gt;
&lt;p&gt;8. On the last page of the LoadBuilder wizard, enter a name for the LoadBuilder run and click Finish.&lt;/p&gt;
&lt;p&gt;9. Review and close the summary dialog. Close the Load Manager.&lt;/p&gt;
&lt;p&gt;10. Model Synchronization&lt;br /&gt;After a successful Property Connection nearest link run, one or more lateral and/or tap elements will be created. Therefore, a drawing needs to be synchronized to display them.&lt;br /&gt;Once the Summary Report and Load Manager are closed, the following dialog will display asking if you want to synchronize the drawing:&lt;br /&gt;If you click Yes, a drawing will be synchronized and new elements will be display. Otherwise, the drawing will remain out-of-sync.&lt;/p&gt;
&lt;h3&gt;Active Topology&lt;/h3&gt;
&lt;p&gt;An element&amp;#39;s active topology state is considered when using LoadBuilder with Property Connection load data. LoadBuilder will not assign a property connection to an inactive element. A Property Connection will only be assigned to a link if both of its nodes are active.&lt;/p&gt;
&lt;h3&gt;Properties of newly created Lateral and Tap elements&lt;/h3&gt;
&lt;p&gt;Newly created Lateral and tap elements will have a default values from the active lateral and tap prototypes respectively.&lt;/p&gt;
&lt;p&gt;If a tap element is created, it will have a reference link (dashed line) connecting it to the nearest pipe. See the following article to remove the dashed line. The&amp;nbsp;dashed line can be turned off by setting the tap property&amp;nbsp;&amp;quot;Show Associated Link Decorations&amp;quot; to False.&lt;/p&gt;
&lt;h3&gt;Property Connection Assignment&lt;/h3&gt;
&lt;p&gt;The nearest element the Property Connection is assigned to will vary for different use cases.&lt;/p&gt;
&lt;h4&gt;When is a tap node created on the nearest link element?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;br /&gt;If the Property Connection makes a perpendicular intersection with the nearest link within 10 feet of, or beyond, the node, but the nearest node is invalid (eg. outfall).&lt;/p&gt;
&lt;h4&gt;When is the nearest node used?&lt;/h4&gt;
&lt;p&gt;If the Property Connection element is not perpendicular to the nearest link.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;If the Property Connection element is perpendicular to the nearest link, and the perpendicular intersection is not within 10ft of a valid node.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;A Property Connection element will be assigned to the nearest node if one of the following are true:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The Property Connection element is close to (within 10ft) the valid node element (ie. manhole, catch basin, transition, cross section, headwall). This 10ft is a fixed distance and can&amp;rsquo;t be modified.&lt;/li&gt;
&lt;li&gt;If the Property Connection element is closer to an applicable node (ie. Manhole, catch basin, transition) then the lateral will be created from the property connection element to the node.&lt;/li&gt;
&lt;/ul&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/30392.property-connections"&gt;Property Connections &lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Craig Calvin&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: isolated, SewerGEMS, LoadBuilder, assign, Property Connection, TAP, lateral&lt;/div&gt;
</description></item></channel></rss>