You are currently reviewing an older revision of this page.
How do I see a graph of actual flow coming in and out of a tank?
The flow (out) and flow (in) values are always same for a tank with just opposite sign, for all the time steps, which does not reciprocate the tank filling range correctly. Because, as soon as any flow leaves the tank towards the junction, it is immediately replaced with flow from the reservoir, so the inflow and outflow values will be nearly identical. You can quickly access the graph of an element by right clicking on the element in the drawing>graph>select the required fields.