Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenFlows | Water Infrastructure
  • Product Communities
  • More
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki Modeling Reference - Valve Closure
    • Sign in
    • OpenFlows | Water infrastructure Wiki
    • +OpenFlows CivilStorm
    • +OpenFlows CulvertMaster
    • +OpenFlows FLOOD
    • +OpenFlows FlowMaster
    • +OpenFlows HAMMER
    • +OpenFlows PondPack
    • +OpenFlows SewerCAD
    • +OpenFlows SewerGEMS
    • +OpenFlows StormCAD
    • +OpenFlows WaterCAD
    • +OpenFlows WaterGEMS
    • +OpenFlows WaterSight
    • +OpenFlows WaterOPS
    • +OpenFlows SewerOPS
    • +Bentley HEC-PACK
    • +General
    • +Help and Documentation
    • +Installation
    • +Licensing / Activation
    • +Integration
    • +Modeling
    • +Layout and Data Input
    • +Calculations
    • +Output and Reporting
    • +Other
    • -OpenFlows Product TechNotes And FAQs
      • +CivilStorm TechNotes and FAQs
      • Combining models with Submodel Import
      • Error publishing to i-model: "No compatible I-model engine was found..."
      • For a modified basket handle shape conduit why is Area (Full Flow) equal to zero after computing?
      • -Hammer TechNotes and FAQs
        • Converting a PRV PSV or FCV to a Throttle Control Valve (TCV) in HAMMER
        • HAMMER General FAQs
        • HAMMER V8 XM General FAQs and Troubleshooting
        • Modeling a Pump Start-Up Transient Event in HAMMER
        • Modeling An Initially Partially Closed Valve
        • Modeling Reference - Air Valves
        • Modeling Reference - Check Valves in HAMMER
        • Modeling Reference - Discharge To Atmosphere
        • Modeling Reference - Hydropneumatic Tanks
        • Modeling Reference - Surge Valves
        • Modeling reference - Turbines
        • Modeling Reference - Valve Closure
        • Modeling Reference - Valve With Linear Area Change
        • Transient Protection Strategies
        • What new in HAMMER CONNECT Update 2.3 - Build 10.02.03.06
        • What's New in HAMMER CONNECT Edition Update 3.2 (10.03.02.75)
        • What's New in HAMMER CONNECT Edition Update 3.3 (version 10.03.03.72)
        • What's new in HAMMER V8i SELECTseries 2?
        • What's New in HAMMER V8i SELECTSeries 3?
        • 水锤软件技术资源
      • Importing an AutoCAD or MicroStation CAD file using ModelBuilder
      • Learning Resource Guide for new users of HAMMER
      • Platform Compatibility
      • +PondPack TechNotes and FAQs
      • Scenario and Alternative Management
      • +SewerCAD TechNotes and FAQs
      • +SewerGEMS TechNotes and FAQs
      • Silent installation for Bentley OpenFlows Products
      • +StormCAD TechNotes and FAQs
      • Understanding the Modified Rational Method
      • Using Fit To Page Printing In The Standalone Platform
      • +WaterGEMS and WaterCAD TechNotes and FAQs
      • What's New in SewerGEMS V8i SELECTseries 5?
      • What's new in SewerGEMS, SewerCAD, StormCAD and CivilStorm CONNECT Edition Update 1 (Build 10.01.01.04)
      • What's New with HAMMER CONNECT Edition
      • What's New with WaterGEMS and WaterCAD CONNECT Edition
    • Check boxes do not appear in tables such as Control Sets dialog
    • Consuming ContextCapture production files within your hydraulic model
    • Convergence NOT achieved Message when computing StormCAD or SewerCAD model
    • Converting Junctions or Hydrants to Isolation Valves
    • Displaying Shapefile Labels (Text) As a Background
    • Enhancing OpenFlows multi-user workflows with ProjectWise Share
    • Error "System.TypeInitializationException"
    • Error 32768 when opening model while integrated with ProjectWise
    • Errors installing patch set
    • Error when opening PondPack: "Object reference not set to an instance of an object" or "Application has generated an exception that could not be handled."
    • Error when saving or validating: System.AccessViolationException: Attempted to read or write protected memory.
    • File Open Dialog does not appear
    • Flextable Report of Multiple Element Types
    • Get to know OpenFlows CONNECT Edition
    • Get to know WaterGEMS, WaterCAD and HAMMER CONNECT Edition
    • How do I import/export multiple point pump curve pump definitions into a model using ModelBuilder?
    • How do you save backup files, so they save at different times and multiple levels?
    • How does the intermediate geodatabase (.MDB or .GDB) file function with ArcMap and ArcGIS Pro integration?
    • How to Delete Engineering Libraries if you get a message about a Read-only database
    • How to receive alerts on new version availability?
    • How to register DAO360.dll or a dll file?
    • How to search using wild cards on a sqlite type of database
    • How to See Hebrew or Arabic text in a .DXF file that was exported from WaterGEMS/WaterCAD
    • Hydraulic grade discontinuity at steep pipes or across nodes (frontwater analysis)
    • I get a red user notification that says, "Inlet guttter mannings n should be greater than 0".
    • Importing .HLB library files from old product versions into format used in the V8 product versions
    • Importing External Data in Geographic Coordinate Systems
    • Importing storm data and other library information from older versions
    • Changing element symbols in the AutoCAD platform
    • Interchange
    • Locating OpenFlows product error log file
    • Locating OpenFlows Product Version Number and License Information
    • Model backward / forward compatibility
    • Multi-user Workflows
    • Modeling a closed loop system
    • Modeling a flow split (diversion) with the SewerCAD or StormCAD numerical solver
    • Modeling turbine load acceptance plus load rejection
    • Multiple CN numbers for a catchment and multiple catchments with a single outlet node
    • Network Navigator Trace Upstream/Downstream does not return any elements
    • OpenFlows software numerical solver theory
    • Percent Connected Impervious Areas and Percent Unconnected Impervious Areas
    • Performing a hydrosanitary design in WaterGEMS or WaterCAD
    • PondPack user notification: "The composite outlet structure is either not selected or deleted."
    • PondPack: How to perform a critical duration analysis?
    • Pressure pipe vs. conduit between pump and wetwell
    • Print Preview > Fit to Page shows blank page
    • Properties not working when using MicroStation integration with ProjectWise
    • Properties, Flextables, user notifications, or other dialog is missing or will not open in standalone
    • Properties, user notifications, or other tool managers not showing up in Integrated version of AutoCAD
    • Reusing Pump Definitions (Import / Export)
    • Reversing orientation of Pipes and Conduits in Bulk
    • Saving a hydraulic model when using the AutoCAD platform (i.e. integrated)
    • Important License Update for OpenFlows Users
    • Setting the invert elevation for multiple conduits coming into one manhole
    • Simple Controls vs. Logical Controls
    • Sorting and relabeling a flextable based on upstream-downstream order
    • Source of the default Specific Speed for pumps and turbines
    • Step by step procedure for finding the curb length needed to capture 100% of gutter flow in a curb inlet with a continuously depressed gutter with no clogging
    • System.Reflection.TargetInvocationException crash when trying to open the application
    • Test Wiki Page - A1
    • Text, cells/blocks and line styles do not display correctly in a DXF background layer
    • The flow annotation (label) in my WaterGEMS for ArcMap isn't reflecting the value displayed in my Geotable or Flextable
    • The total area in the CN/Area Collection does not equal the total catchment area
    • Time tolerance setting in SCADAConnect Simulator
    • Troubleshooting ArcMap / ArcGIS Integration
    • Turbine Efficiency
    • Understanding Flow (Additional Subsurface) and Flow (Additional Carryover)
    • Upcoming training and release dates for OpenFlows products
    • User notification "Downstream TW out of range..."
    • User notification "Pump exceeds the maximum operating point specified for the pump curve"
    • User Notification - The captured surface flow at this node does not connect a valid subsurface network. The flow is lost from the system.
    • User Notification: "There is an error in the data for this pipe. The associated data is incorrect"
    • User Notification: Cross section maximum elevation is above the maximum headwater elevation
    • User Notifications: "Pump On elevation is not in the range of upstream ...." and "Off elevation of pump is lower than ..."
    • Using batch pipe split to fix nodes that overlay a pipe instead of connecting to it
    • Using PondMaker with different tailwater for each return event
    • Valve "Status (Initial)" Definitions
    • Velocity Calculations and the Average Velocity Methods in SewerCAD and StormCAD
    • Viewing graph data for multiple scenarios
    • Water age results in a pipe are different from the age in the downstream junction
    • Water Loss Management
    • Water quality Analysis during transient events
    • WaterGems Tips
    • What are the limitations of importing/exporting EPANET files?
    • What is the dotted line that is associated with the isolation valves? Can I turn them off?
    • What's new in WaterCAD, WaterGEMS and HAMMER V8i SELECTseries 6 with CONNECT Integration?
    • What's New in WaterOPS CONNECT Edition 2.3 (Build 10.02.03.06)
    • When the user changes the fluid, why doesn't the calculated pump head change?
    • Working From Home With Your OpenFlows Software
    • "An error occurred when trying to calibrate the model"
    • "COM Error Not Documented" when opening OpenFlows product
    • "Default license feature configuration not found. Product features may be limited. Please run the License Administrator."
    • "The Depth-Flow, Depth-Flow (Simulated Variable Speed) and Volume-Flow pump definition types are unsupported"
    • "Unable to assign attribute ... for element because enumeration value ... is not valid."
    • Add custom data to profile with User Data Extensions
    • After computing a model with the SWMM solver, what does the following warning mean: "Maximum depth increased for node CB-XX"?
    • After computing the model, the pump efficiency results are listed as N/A
    • After running loadbuilder I get a message that says "The layer <Layer_Name> could not be opened."
    • At what point does OpenFlows product license usage start when integrated with MicroStation?
    • Background image quality poor on some computers or Crash when opening models with background layers
    • Blocky stepwise pattern is displayed instead of a continous smooth pattern that was entered when using the SWMM engine
    • Can User Data Extensions be shared between elements in a model?
    • Catch basins imported as manholes from LandXML
    • Change in results before turbine load rejection occurs
    • Custom quadrant curve not being recognized
    • Date-time based query not working
    • Default license configuration not retaining setting
    • Do inactive elements count against the license count?
    • Does HAMMER support initially negative pressures?
    • Does the friction method affect local minor loss in pipes?
    • Does WaterGEMS and WaterCAD report pressures as gauge pressure or absolute pressure?
    • Efficiency Curve vs. Wire-to-Water Efficiency Curve
    • Error importing a LandXML file from StormCAD into Civil 3D "A pipe or conduit had an unsupported geometry"
    • Error message when validating model: "Elevation (Relative) values within the Irregular shape definition must be non-negative."
    • Error message: "Unrecognized database format ..." when trying to open model
    • Error Saving: "Custom results path is invalid"
    • Find if pump operates off of the pump curve during an automated fire flow scenario
    • Flow arrows are not included in an exported DGN file when using the Save Symbology option in the MicroStation platform
    • Flow from pump is delayed after pump startup
    • GeoPak - StormCAD errors - GEOPAK runtime environment not found / Error writing GEOPAK/PowerCivil node
    • HEC-22 2nd edition energy loss calculations with the Implicit solver
    • How are "pipe sets" and "nodes of interest" used in a flushing analysis to get auxiliary results at other elements?
    • How can I see the amount of inflow or outflow occuring for a particular surge tank during the transient simulation in HAMMER?
    • How do I filter a column in my flextable using a custom query that retrieves all records with a <None> attribute?
    • How do I know if and when my pond is overtopping and how to quantify it?
    • How do I save my model files when working in the ArcMap or ArcGIS Pro platform?
    • How do the channel slopes and velocity effect the headloss formulas in SewerCAD and StormCAD?
    • How does StormCAD handle gutter flow from an active catch basin to an inactive catch basin?
    • How does the diameter of an isolation valve effect the calculated results?
    • How to add comments on custom pump and turbine quadrant curves
    • How to find volume of water coming from a trace element?
    • How to open a .PRNX report file created on exporting custom report in OpenFlows product
    • Hydropneumatic tank atmospheric pressure not changing results
    • Hydropneumatic tank profile animation and time history shows zero gas volume
    • Initial surge when using turbine load acceptance operating case
    • Initial turbine HGL the same as the final HGL after load acceptance
    • Irregular Weir Flow Calculations in a Composite Outlet Structure
    • Is it possible to create old PondPack style text reports?
    • Is it possible to have a storm event start at a different time than the model simulation?
    • Is it possible to use point cloud information to populate elevations in Terrain Extractor (TRex)?
    • Is there a recommended level of Skelebration for different modeling conditions?
    • Junctions are created on top of one another after using ModelBuilder with the GIS-ID property
    • Learning Resource Guide for WaterSight
    • License usage in the ArcMap and ArcGIS Pro platform
    • LoadBuilder applying demands or loads to inactive elements
    • LoadBuilder importing zero flow loads
    • Long time to load background layers
    • Manage Pump Speed Series
    • Manage Pump Time Series
    • Managing large number of scenarios
    • Missing Young's Modulus and Poisson's Ratio values in the material library
    • Modeling Arch section shapes in SewerGEMS
    • Modeling closed or pressurized pipes in PondPack
    • Modeling treatment for pollutants at nodes or ponds in SewerGEMS and CivilStorm
    • MrSid files are not available as a background layer type or an error is generated when loading MrSid files
    • +OpenFlows Academic Books
    • Pipe Renewal Planner Vs OpenFlows WaterCAP
    • Pipes connecting to the wrong element after submodel import
    • Pipes not merging when using Skelebrator with series pipe merging
    • PondPack error: Unable to open user roster
    • Problems opening GEOPAK Drainage file exported from StormCAD
    • Query, alert or formula UDX not working correctly with "=" (equals)
    • SCADAConnect in SewerGEMS
    • SCADAConnect Simulator in WaterCAD and WaterGEMS V8i SELECTseries 5
    • Series Pipe Merging in Skelebrator not working for pipes with zero diameter
    • Small difference in gutter worksheet result between US and SI units
    • The concentration at the stop node directly after a constituent source in a tank is decreasing rapidly
    • The control symbol, check valve symbol, and dashed lines connecting customer meters, isolation valves, and SCADA elements are not visible in the ArcMap or ArcGIS Pro platforms
    • The headloss in a pipe downstream of a parallel VSP is higher than expected
    • The result field "Depth (Flooding)" is listed as N/A after computing a model with the SWMM engine. Is there a way to see the depth of flooding for a node?
    • Translated version still showing as English
    • Troubleshooting making a SCADA connection to Oracle database
    • Troubleshooting ModelBuilder issues and errors connecting to an Oracle database
    • User Data Extension not appearing in the Post-Calculation Processor's "Output Property" field
    • User Data Extensions in the Fireflow report
    • User Notification "More than one VSPB cannot control the same control node"
    • User notification when computing: IDF data is not supported by SWMM. Storm event is excluded from export.
    • User notification: "Conduit has a Stop control structure, but this is not supported next to the connected outfall element."
    • User notification: "Transition from CONCENTRATED to EXTENDED"
    • Using Imperial and Metric Hydro International Vortex Valves
    • Using US Survey feet
    • Warning about outlet hydrograph not cresting
    • WaterGEMS and WaterCAD Data Import FAQ
    • WaterSight - Pump Overview
    • What can I do to speed it up a file I need to extract elevations from is taking a long time to process in TRex?
    • What does Entrance Control mean?
    • What is the best way to model an orifice plate inside a catchbasin with surface storage above the catchbasin rim?
    • What is the difference between a stand pipe and an inlet box?
    • What is the purpose the Rainfall File, Runoff File, and RDII File in the Calculations Options?
    • What is the workflow for setting up pre and postdeveloped conditions for multiple return events?
    • What kind of demands should be used as the initial conditions of a transient simulation?
    • What's new in HAMMER V8i SELECTseries 6?
    • When running a query, why is it not picking up the elements that it should?
    • Why are there 2 entries for the same alternative in the dropdown menu in the properties of a scenario? One with an "i" and one without it.
    • Why are there so many extra element types listed for WaterGEMS and WaterCAD, such as surge tank, rupture disk, Periodic head-flow?
    • Why do I get a warning message about the rational method being used for the modified rational method?
    • Will SCADA Results Publishing work with only OPC sources?

    You are currently reviewing an older revision of this page.

    • History View current version

    Modeling Reference - Valve Closure

      Applies To 
      Product(s): HAMMER, WaterGEMS, WaterCAD
      Version(s): V8i, CONNECT Edition
      Area:  Modeling
      Original Author: Jesse Dringoli, Bentley Technical Support Group

    Overview

    This technote explains how various types of valves work and their typical application in HAMMER and in WaterGEM / WaterCAD. It also provides an example model file for demonstration purposes. A video demonstration is found at the bottom.

     

    Primary Valve Elements

    The main "valves" icon on the layout toolbar offers several generic valves: GPV, TCV, FCV, PRV, PSV and PBV. These are sometimes collectively referred to as "valves of various types" in older versions of HAMMER.

     

     

    These valve elements serve various purposes and are frequently used in steady state or Extended Period hydraulic models. They can generally be categorized as flow control. For example, the GPV defines a curve of flow versus headloss, the FCV (Flow Control Valve) controls flow to a set point and the PRV (Pressure Reducing Valve) controls the downstream pressure to be below a set point.  

    The important thing to understand about dynamic valves like FCVs, PSVs and PRVs is that their controlling effects (pressure reduction, flow control, etc) only apply to the initial conditions calculation (steady state or EPS). For a given steady state or EPS timestep, a specific headloss occurs across the valve. For example, in order for the PSV element to sustain upstream pressure, a specific headloss occurs through the valve, such that in order to balance energy across the network, the upstream hydraulic grade ends up being higher than the PSV set point. During the transient simulation, a discharge coefficient is calculated based on that valve's headloss during the initial conditions timestep. 

    Note: the following equation is used to convert between headloss coefficient and discharge coefficient: H = 39.693 * D^4/Cv^2 Where: D = Diameter (ft), H = Headloss coefficient (K), Cv = discharge coefficient (cfs/ftH20^0.5) It can be re-written as: Cv = ((39.693 * D^4) / H)^0.5

    As the transient simulation progresses and the system conditions change, these valves will not automatically react, like they do during the initial conditions. Meaning, if the transient conditions cause a higher flow through a FCV, it will not automatically throttle (change its headloss) to react accordingly. The reason is because HAMMER assumes that these valves cannot react fast enough during the transient simulation. So, they will stay in a fixed position based on the aforementioned discharge coefficient from the initial conditions. 

    However, the user can manually open and close these valves during the transient simulation by using the Operating Rule. The operating rule is an attribute of the valve, found under the "Transient (Operational)" section of the properties. It allows you to define a pattern of Time versus Relative closure, to be using during the transient simulation.  

    Note: PRVs are currently an exception to this, as they have the ability to modulate (throttle automatically to meet a setpoint) during the transient simulation. See related article: Using Modulating PRVs 

     

     

    For example, if you have a gate valve that is fully open in the initial conditions and you want it to fully close during the transient simulation, you could define your operating rule with a starting relative closure of 0% and pattern that rises to 100% at some point. You would then select that in the valve's properties, under the "Operating Rule" field. You can analyze the effect of various closure patterns either by manually changing the operating rule and re-running the simulation or by creating multiple scenarios, computing a batch run in the scenario manager and then individually examining the transient results.  

    Note: The operating rule designation is stored in the "Transient" alternative. 

     

    Generally the transient surge will be more severe for a faster closure. So, typically the last bit of closure should occur slowly. For example, the valve may close quickly between 0% and 95% closure, then slowly close for the last 5%. However, you may want to analyze the worst case scenario where the valve is closed too quickly. The speed of closure can easily be reflected in your Operating rule pattern.  

    Note: Do not confuse the Operating Rule with the "Pattern (Valve Settings)" or "Pattern (relative closure)". The latter two fields may be found under the "physical" section of the valve's properties and are used to establish a manual closure pattern for the valve during the initial conditions (EPS) only. 

     

    For general valve closure purposes such as gate valves, isolation valves, etc, it is recommended that you use the TCV valve type (throttle control valve). This valve represents a standard headloss or discharge coefficient during the initial conditions. So, in the above example of an initially open valve, you would specify the loss coefficient representing the losses through the fully open valve.  

    Other Valve Types

    Valve with Linear Area Change - The "Valve with Linear Area Change" element represents a simplified valve that either closes linearly (with respect to area) or acts as a check valve that stays closed upon reverse flow. The user only specifies a time to close, so no delay can be incorporated with the closure. Meaning, it starts closing as soon as the transient simulation begins. See more here: Modeling Reference - Valve With Linear Area Change

    Pump valves - The pump element has a built-in valve, that can either operate as a check valve (when the "Pump Valve Type" is set to "check valve") or a linearly closing valve (with the "Pump Valve Type" set to "Control Valve"). The Control valve will either open or close over a given duration, depending on the initial status of the pump (on or off). See also: Modeling a pump that has neither a check valve nor a control valve

    Check valves - a check valve can be simulated in a pipe, as a separate node element, and built into a pump. These close upon reverse flow. A slow closing operation can be modeled with the check valve node element. More on this here: Modeling Reference - Check Valves

    Isolation valve - this element can be associated with the pipe, so it has the benefit of not adding an extra pipe from a split. However, the operation of this type of valve cannot be simulated during a transient simulation. Meaning, it can only be used to set the initial status of the related pipe to open or closed. If you need to control an isolation valve, use the TCV element instead. 

     

    Initially Partially Closed Valves 

    The TCV also has the ability to model the opening/closing of a valve that is initially partially closed. This is done by way of the "valve characteristics curve" coefficient type and "Valve Type". Normally, the discharge coefficient that the program computes based on what the valve is doing during the initial conditions is interpretted by HAMMER as the fully open position. For example, if you use a GPV, the headloss calculated through it in the initial conditions is always interpretted as a relative closure of 0%, even though in reality, it may be partially closed. This can cause confusion when defining the operating rule. However, with the valve characteristics curve coefficient type for a TCV, the user can define the relationship of discharge coefficient versus relative closure; therefore, a partially closed valve can be properly modeled. Detailed instructions on how to do this are beyond the scope of this technote. For more information, please see Modeling An Initially Partially Closed Valve  

     

    Custom Valve Characteristics

    By default, several standard valve types are available, in the "valve type" field (such as butterfly, globe, needle). This essentially defines the discharge coefficient that HAMMER uses for various values of "relative closure" in the operating rule. For example, some valves may have a sharp reduction in area as they start to close (stroke) and then a slower reduction in area just before they are fully closed. Meaning, a value of 90% closure in your operating rule might not necessarily mean the valve's open area is 10% of the original area. The user can also define a user defined table of relative closure versus relative discharge coefficient, by selecting "user defined" as the valve type.

    This exposes the "Valve Characteristics" attribute, which is where you would enter the table of relative closure versus relative discharge coefficient to define the characteristics of your valve. The relative discharge coefficient values are relative to the value entered for "Discharge Coefficient (fully open)".  

    Valve Characteristic Curves

    Valve characterisic cuves for standard types are based on published data (Fok, 1987). The curves have the functional form:

    1 – Yk ...

    where needle valves have k = 2.0; circular gate valves, k = 1.35; and globe valves k = 1.0;

    or

    (1 – Y )k ...

    where for ball valves, k = 1.35; and butterfly valves, k = 1.85.

    More information can be found at the following paper:

    Fok, A.T.K., “A Contribution to the Analysis of Energy Losses in Transient Pipe Flow”, Ph.D. Thesis, University of Ottawa, 1987.

    Note: most valve manufacturers can provide the discharge coefficient(s) 

     

     

    Note: When modeling a valve whose initial status is "inactive", ensure that you've entered a value for the "minor loss coefficient". When computing initial conditions, the "minor loss coefficient" is used to compute headloss through the fully open (inactive) valve. This headloss is important since it is used to define the relationship between head loss and discharge as the valve closes. 

    Example Model

    In the latest version of HAMMER, this example model can be found in the "Samples" folder within the installation folder and is called "Valve_Closure_Example.wtg". For older versions that do not have this, you can download a version of it here:

    Click to Download

    Note: the above model is for example purposes only. It can be opened in version 08.11.00.30 and above and you can find additional information under File > Project Properties. Also, you must be signed in to Bentley Communities or the link will not work.

    Video Demonstration - transient valve closure

    A video demonstration of advanced valve closure modeling is available within the HAMMER Learning path on Learn.bentley.com. See the on-demand video named "Causes of Transients - Valves". This training course is also available on our YouTube channel, and the video in question is embedded below:

    Reference

    1. Advanced Water Distribution Modeling and Management - Walski, 2007

    See Also

    Gradual closure not occurring when using valve operating rule

    Protective Equipment FAQ

    Modeling An Initially Partially Closed Valve

    Modeling Reference - Valve With Linear Area Change

    Using Modulating PRVs 

    General HAMMER V8i FAQ

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies