Product(s): |
SewerGEMS, CivilStorm, StormCAD, SewerCAD |
Version(s): |
10.01.00.70 |
Area: |
Output and reporting |
Problem
When viewing an Engineering Profile after opening a model saved in an older version, the program crashes, with the following details displayed when clicking the details button:
System.IO.EndOfStreamException: Unable to read beyond the end of the stream.
at System.IO.__Error.EndOfFile()
at System.IO.BinaryReader.FillBuffer(Int32 numBytes)
at System.IO.BinaryReader.ReadSingle()
at Haestad.Calculations.GVFResultReader.GVFTimeStepOutputReader.GetConduitProfileCollection(DataTable& profileTable, Int32 timeStepIndex, Int32 conduitId)
...
Solution
This is a known issue that can occur (up to version 10.01.00.70) in engineering profiles with output files saved in an older version. Reference # 796460.
The solution is to either re-compute the model in the new version and try again, contact technical support for the latest cumulative patch set or download a newer version when available.
See Also
Downloading OpenFlows | Hydraulics and Hydrology Software
How to receive alerts on new version availability