Product(s): |
WaterGEMS, WaterCAD |
Version(s): |
10.03.03.72 |
Area: |
Layout and Data Input |
Problem
When entering the local bulk reaction rate for tank or any other elements (like junctions), the program throws an exception as below;
Solution
This happens when setting the "Specify Local Bulk Rate?" to "True" and specifying a value in the properties of a tank, junction or any other model element. After entering the value the exception is thrown and the value is not considered. However, the values can be directly changed in the Constituent alternative for the required elements.
This is a known bug in WaterGEMS (v 10.03.03.72) which has been identified and fixed with a patch set and consequently is fixed in later versions of WaterGEMS. Please contact Bentley Technical Support for information on the patch set.
See Also
Cumulative patch sets for Hydraulics and Hydrology products