Product(s): |
SewerGEMS, WaterGEMS, HAMMER, SewerCAD, StormCAD, CivilStorm, WaterCAD |
Version(s): |
10.XX.XX.XX |
Area: |
Other |
Problem
SewerGEMS (or other products) icons in the ribbon menu and workflows appear distorted.
Solution
This problem is related to products installed on DELL machines which run AWCC Service i.e., the AlienWare Command Center.
Please follow the below steps to resolve this issue:
1. Ensure SewerGEMS is closed
2. In Windows explorer, navigate to the folder C:\ProgramData\A-Volute\DellInc.AlienwareSoundCenter\Modules\ScheduledModules\Configurator
3. Open the any text editor (like notepad, notepad++) in administrator mode and open the "BlackApps.dat" file
4. Add the following list of executables as exceptions at the end of the BlackApps.dat file
SewerGEMS.exe
dw.exe stmc.exe
STMCsys.exe
swrc.exe
SWRCsys.exe
Haestad.DesignSynchronizer.exe
WaterObjects.Net.PostCalculationProcessor.exe
Haestad.ModelBuilder.BatchImport.Driver.exe
Haestad.Integrator.exe
DesignSyncViewer.exe
DgnNavigatorAx.exe
5. Save the BlackApps.dat file
6. Open Task Manager and go to "Services" and search for "AWCCService" - Right click and "Restart"
7. Launch SewerGEMS and the problem should be fixed.
Note: This issue has also been observed in other Bentley applications like STAAD.Pro. See the related wiki article for exceptions to be added for STAAD.Pro here.
See Also
Forum Post - OpenFlows SewerGEMS - Graphical Glitches caused by Alienware software on Dell PCs Resolved