Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenFlows | Water Infrastructure
  • Product Communities
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki What's New with StormCAD V8i SELECTseries 3?
    • Sign In
    • OpenFlows | Water infrastructure Wiki
    • +OpenFlows CivilStorm
    • +OpenFlows CulvertMaster
    • +OpenFlows FLOOD
    • +OpenFlows FlowMaster
    • +OpenFlows HAMMER
    • +OpenFlows PondPack
    • +OpenFlows SewerCAD
    • +OpenFlows SewerGEMS
    • +OpenFlows StormCAD
    • +OpenFlows WaterCAD
    • +OpenFlows WaterGEMS
    • +OpenFlows WaterSight
    • +OpenFlows WaterOPS
    • +OpenFlows SewerOPS
    • +Bentley HEC-PACK
    • +General
    • +Help and Documentation
    • +Installation
    • +Licensing / Activation
    • +Integration
    • +Modeling
    • +Layout and Data Input
    • +Calculations
    • +Output and Reporting
    • +Other
    • -OpenFlows Product TechNotes And FAQs
      • +CivilStorm TechNotes and FAQs
      • Combining models with Submodel Import
      • Error publishing to i-model
      • For a modified basket handle shape conduit why is Area (Full Flow) equal to zero after computing?
      • +Hammer TechNotes and FAQs
      • Importing an AutoCAD or MicroStation CAD file using ModelBuilder
      • Learning Resource Guide for new users of HAMMER
      • Platform Compatibility
      • +PondPack TechNotes and FAQs
      • Scenario and Alternative Management
      • +SewerCAD TechNotes and FAQs
      • +SewerGEMS TechNotes and FAQs
      • Silent installation for Bentley OpenFlows Products
      • -StormCAD TechNotes and FAQs
        • StormCAD General FAQs
        • What's new in StormCAD CONNECT Edition
        • What's New in StormCAD SELECTseries 4
        • What's new in StormCAD V8i SELECTseries 2?
        • What's new in StormCAD V8i SELECTseries 5?
        • What's New with StormCAD V8i SELECTseries 3?
      • Understanding the Modified Rational Method
      • Using Fit To Page Printing In The Standalone Platform
      • +WaterGEMS and WaterCAD TechNotes and FAQs
      • What's New in SewerGEMS V8i SELECTseries 5?
      • What's new in SewerGEMS, SewerCAD, StormCAD and CivilStorm CONNECT Edition Update 1 (Build 10.01.01.04)
      • What's New with HAMMER CONNECT Edition
      • What's New with WaterGEMS and WaterCAD CONNECT Edition
    • Check boxes do not appear in tables such as Control Sets dialog
    • Consuming ContextCapture production files within your hydraulic model
    • Convergence NOT achieved Message when computing StormCAD or SewerCAD model
    • Converting Junctions or Hydrants to Isolation Valves
    • Displaying Shapefile Labels (Text) As a Background
    • Enhancing OpenFlows multi-user workflows with ProjectWise Share
    • Error "System.TypeInitializationException"
    • Error 32768 when opening model while integrated with ProjectWise
    • Errors installing patch set
    • Error when opening PondPack: "Object reference not set to an instance of an object" or "Application has generated an exception that could not be handled."
    • Error when saving or validating: System.AccessViolationException: Attempted to read or write protected memory.
    • File Open Dialog does not appear
    • Flextable Report of Multiple Element Types
    • Get to know OpenFlows CONNECT Edition
    • Get to know WaterGEMS, WaterCAD and HAMMER CONNECT Edition
    • How do I import/export multiple point pump curve pump definitions into a model using ModelBuilder?
    • How do you save backup files, so they save at different times and multiple levels?
    • How does the intermediate geodatabase (.MDB or .GDB) file function with ArcMap and ArcGIS Pro integration?
    • How to Delete Engineering Libraries if you get a message about a Read-only database
    • How to receive alerts on new version availability?
    • How to register DAO360.dll or a dll file?
    • How to search using wild cards on a sqlite type of database
    • How to See Hebrew or Arabic text in a .DXF file that was exported from WaterGEMS/WaterCAD
    • Hydraulic grade discontinuity at steep pipes or across nodes (frontwater analysis)
    • I get a red user notification that says, "Inlet guttter mannings n should be greater than 0".
    • Importing .HLB library files from old product versions into format used in the V8 product versions
    • Importing External Data in Geographic Coordinate Systems
    • Importing storm data and other library information from older versions
    • Changing element symbols in the AutoCAD platform
    • Interchange
    • Locating OpenFlows product error log file
    • Locating OpenFlows Product Version Number and License Information
    • Model backward / forward compatibility
    • Multi-user Workflows
    • Modeling a closed loop system
    • Modeling a flow split (diversion) with the SewerCAD or StormCAD numerical solver
    • Modeling turbine load acceptance plus load rejection
    • Multiple CN numbers for a catchment and multiple catchments with a single outlet node
    • Network Navigator Trace Upstream/Downstream does not return any elements
    • OpenFlows software numerical solver theory
    • Percent Connected Impervious Areas and Percent Unconnected Impervious Areas
    • Performing a hydrosanitary design in WaterGEMS or WaterCAD
    • PondPack user notification: "The composite outlet structure is either not selected or deleted."
    • Pressure pipe vs. conduit between pump and wetwell
    • Print Preview > Fit to Page shows blank page or Reports will not print
    • Properties not working when using MicroStation integration with ProjectWise
    • Properties, Flextables, user notifications, or other dialog is missing or will not open or appears to freeze the program
    • Properties, user notifications, or other tool managers not showing up in Integrated version of AutoCAD
    • Reusing Pump Definitions (Import / Export)
    • Reversing orientation of Pipes and Conduits in Bulk
    • Saving a hydraulic model when using the AutoCAD platform (i.e. integrated)
    • Important License Update for OpenFlows Users
    • Setting the invert elevation for multiple conduits coming into one manhole
    • Simple Controls vs. Logical Controls
    • Sorting and relabeling a flextable based on upstream-downstream order
    • Source of the default Specific Speed for pumps and turbines
    • Procedure for finding the curb length needed to capture 100% of gutter flow in a curb inlet with a continuously depressed gutter with no clogging
    • System.Reflection.TargetInvocationException crash when trying to open the application
    • Test Wiki Page - A1
    • Text, cells/blocks and line styles do not display correctly in a DXF background layer
    • The flow annotation (label) in my WaterGEMS for ArcMap isn't reflecting the value displayed in my Geotable or Flextable
    • The total area in the CN/Area Collection does not equal the total catchment area
    • Time tolerance setting in SCADAConnect Simulator
    • Troubleshooting ArcMap Integration
    • Turbine Efficiency
    • Understanding Flow (Additional Subsurface) and Flow (Additional Carryover)
    • Upcoming training and release dates for OpenFlows products
    • User notification "Downstream TW out of range..."
    • User notification "Pump exceeds the maximum operating point specified for the pump curve"
    • User Notification - The captured surface flow at this node does not connect a valid subsurface network. The flow is lost from the system.
    • User Notification: "There is an error in the data for this pipe. The associated data is incorrect"
    • User Notification: Cross section maximum elevation is above the maximum headwater elevation
    • User Notifications: "Pump On elevation is not in the range of upstream ...." and "Off elevation of pump is lower than ..."
    • Using batch pipe split to fix nodes that overlay a pipe instead of connecting to it
    • Using PondMaker with different tailwater for each return event
    • Valve "Status (Initial)" Definitions
    • Velocity Calculations and the Average Velocity Methods in SewerCAD and StormCAD
    • Viewing graph data for multiple scenarios
    • Water age results in a pipe are different from the age in the downstream junction
    • Water Loss Management
    • Water quality Analysis during transient events
    • WaterGems Tips
    • What are the limitations of importing/exporting EPANET files?
    • What is the dotted line that is associated with the isolation valves? Can I turn them off?
    • What's new in WaterCAD, WaterGEMS and HAMMER V8i SELECTseries 6 with CONNECT Integration?
    • What's New in WaterOPS CONNECT Edition 2.3 (Build 10.02.03.06)
    • When the user changes the fluid, why doesn't the calculated pump head change?
    • Working From Home With Your OpenFlows Software
    • "An error occurred when trying to calibrate the model"
    • "COM Error Not Documented" when opening OpenFlows product
    • "Default license feature configuration not found. Product features may be limited. Please run the License Administrator."
    • "The Depth-Flow, Depth-Flow (Simulated Variable Speed) and Volume-Flow pump definition types are unsupported"
    • "Unable to assign attribute ... for element because enumeration value ... is not valid."
    • Add custom data to profile with User Data Extensions
    • After computing a model with the SWMM solver, what does the following warning mean: "Maximum depth increased for node CB-XX"?
    • After computing the model, the pump efficiency results are listed as N/A
    • After running loadbuilder I get a message that says "The layer <Layer_Name> could not be opened."
    • Arch section shape modeling limitations
    • At what point does OpenFlows product license usage start when integrated with MicroStation?
    • Background image quality poor on some computers or Crash when opening models with background layers
    • Blocky stepwise pattern is displayed instead of a continous smooth pattern that was entered when using the SWMM engine
    • Calculating ellipse coefficients in CulvertMaster
    • Calculation of Side Flow factor with grate width less than gutter width
    • Can User Data Extensions be shared between elements in a model?
    • Catch basins imported as manholes from LandXML
    • Change in results before turbine load rejection occurs
    • Conduit "Size" attribute does not appear correctly in annotations or reports
    • Custom quadrant curve not being recognized
    • Date-time based query not working
    • Default license configuration not retaining setting
    • Do inactive elements count against the license count?
    • Does HAMMER support initially negative pressures?
    • Does the friction method affect local minor loss in pipes?
    • Does WaterGEMS and WaterCAD report pressures as gauge pressure or absolute pressure?
    • Efficiency Curve vs. Wire-to-Water Efficiency Curve
    • Error importing a LandXML file from StormCAD into Civil 3D "A pipe or conduit had an unsupported geometry"
    • Error message when validating model: "Elevation (Relative) values within the Irregular shape definition must be non-negative."
    • Error message: "Unrecognized database format ..." when trying to open model
    • Error Saving: "Custom results path is invalid"
    • Find if pump operates off of the pump curve during an automated fire flow scenario
    • Flow arrows are not included in an exported DGN file when using the Save Symbology option in the MicroStation platform
    • Flow from pump is delayed after pump startup
    • HAMMER error: "Zero initial head from pump (turbine). Change at least one of the heads at the pump ends of the adjacent pipes."
    • HEC-22 2nd edition energy loss calculations with the Implicit solver
    • How are "pipe sets" and "nodes of interest" used in a flushing analysis to get auxiliary results at other elements?
    • How can I see the amount of inflow or outflow occuring for a particular surge tank during the transient simulation in HAMMER?
    • How can I speed up computing a model that I need to extract elevations from - it is taking a long time to process in TRex?
    • How do I filter a column in my flextable using a custom query that retrieves all records with a <None> attribute?
    • How do I know if and when my pond is overtopping and how to quantify it?
    • How do I save my model files when working in the ArcMap or ArcGIS Pro platform?
    • How do the channel slopes and velocity effect the headloss formulas in SewerCAD and StormCAD?
    • How do you define the starting conditions of the transient simulation?
    • How does StormCAD handle gutter flow from an active catch basin to an inactive catch basin?
    • How does the diameter of an isolation valve effect the calculated results?
    • How to add comments on custom pump and turbine quadrant curves
    • How to find volume of water coming from a trace element?
    • How to open a .PRNX report file created on exporting custom report in OpenFlows product
    • Hydropneumatic tank atmospheric pressure not changing results
    • Hydropneumatic tank profile animation and time history shows zero gas volume
    • Initial surge when using turbine load acceptance operating case
    • Initial turbine HGL the same as the final HGL after load acceptance
    • Irregular Weir Flow Calculations in a Composite Outlet Structure
    • Is it possible to create old PondPack style text reports?
    • Is it possible to have a storm event start at a different time than the model simulation?
    • Is it possible to use point cloud information to populate elevations in Terrain Extractor (TRex)?
    • Is there a recommended level of Skelebration for different modeling conditions?
    • Is there a way to model a rectangular pipe in WaterCAD, WaterGEMS or HAMMER?
    • Junctions are created on top of one another after using ModelBuilder with the GIS-ID property
    • Learning Resource Guide for WaterSight
    • License usage in the ArcMap and ArcGIS Pro platform
    • LoadBuilder applying demands or loads to inactive elements
    • LoadBuilder importing zero flow loads
    • Log4net issues appear in security scans for OpenFlows products
    • Long time to load background layers
    • Manage Pump Speed Series
    • Manage Pump Time Series
    • Managing large number of scenarios
    • Missing Young's Modulus and Poisson's Ratio values in the material library
    • Modeling closed or pressurized pipes in PondPack
    • Modeling culverts in series in CulvertMaster
    • Modeling treatment for pollutants at nodes or ponds in SewerGEMS and CivilStorm
    • MrSid files are not available as a background layer type or an error is generated when loading MrSid files
    • My scenario label is not in my report preview when I run the report builder
    • +OpenFlows Academic Books
    • Pipe Renewal Planner Vs OpenFlows WaterCAP
    • Pipes connecting to the wrong element after submodel import
    • Pipes not merging when using Skelebrator with series pipe merging
    • PondPack error: Unable to open user roster
    • Post calculation processor tool error: The result property and output property have no common supported element types.
    • Problems opening GEOPAK Drainage file exported from StormCAD
    • Purpose of the Virtual Flow Depth Calculation Option
    • Query, alert or formula UDX not working correctly with "=" (equals)
    • Red user notification, "Post engine loading process encountering unexpected data. Please rectify any validation errors and try again."
    • Reporting pressure available at the exact total needed fire flow
    • SCADAConnect in SewerGEMS
    • Series Pipe Merging in Skelebrator not working for pipes with zero diameter
    • Sharing Queries for use in other models
    • Small difference in gutter worksheet result between US and SI units
    • The concentration at the stop node directly after a constituent source in a tank is decreasing rapidly
    • The control symbol, check valve symbol, and dashed lines connecting customer meters, isolation valves, and SCADA elements are not visible in the ArcMap or ArcGIS Pro platforms
    • The headloss in a pipe downstream of a parallel VSP is higher than expected
    • The result field "Depth (Flooding)" is listed as N/A after computing a model with the SWMM engine. Is there a way to see the depth of flooding for a node?
    • Translated version still showing as English
    • Troubleshooting ArcGIS Pro Integration
    • Troubleshooting making a SCADA connection to Oracle database
    • Troubleshooting ModelBuilder issues and errors connecting to an Oracle database
    • Unexpected small flow in pipes that should have zero flow
    • Use of the Gas Law Exponent During Initial Conditions vs. Transient simulation
    • User Data Extension not appearing in the Post-Calculation Processor's "Output Property" field
    • User Data Extensions in the Fireflow report
    • User Notification "More than one VSPB cannot control the same control node"
    • User notification when computing: IDF data is not supported by SWMM. Storm event is excluded from export.
    • User notification: "Conduit has a Stop control structure, but this is not supported next to the connected outfall element."
    • User notification: "Transition from CONCENTRATED to EXTENDED"
    • Using Imperial and Metric Hydro International Vortex Valves
    • Using US Survey feet
    • Warning about outlet hydrograph not cresting
    • WaterGEMS and WaterCAD Data Import FAQ
    • WaterSight - Pump Overview
    • +WaterSight Learning Resource Guide
    • Wetwell flooded warning in steady state with GVF Convex (SewerCAD) solver
    • What does Entrance Control mean?
    • What is the best way to model an orifice plate inside a catchbasin with surface storage above the catchbasin rim?
    • What is the difference between a stand pipe and an inlet box?
    • What is the purpose the Rainfall File, Runoff File, and RDII File in the Calculations Options?
    • What is the workflow for setting up pre and postdeveloped conditions for multiple return events?
    • What kind of demands should be used as the initial conditions of a transient simulation?
    • What's new in HAMMER V8i SELECTseries 6?
    • When running a query, why is it not picking up the elements that it should?
    • Why are there 2 entries for the same alternative in the dropdown menu in the properties of a scenario? One with an "i" and one without it.
    • Why are there so many extra element types listed for WaterGEMS and WaterCAD, such as surge tank, rupture disk, Periodic head-flow?
    • Why do I get a warning message about the rational method being used for the modified rational method?
    • Will SCADA Results Publishing work with only OPC sources?

    You are currently reviewing an older revision of this page.

    • History View current version

    What's New with StormCAD V8i SELECTseries 3?

       
      Applies To 
       
      Product(s): Bentley StormCAD
      Version(s): V8i SELECTseries 3 (08.11.03.77)
      Environment:  N/A
      Area:  N/A
      Subarea:  N/A
      Original Author: Mark Pachlhofer, Bentley Technical Support Group
       

     

     

     

     

     

     

     

     

    Overview

    The SELECTseries 3 release of StromCAD includes many new features and improvements. Let's explore each of these in detail.

    - Support for Newer Platforms and Operating Systems
    - Unified schema and one common data file format
    - Keyword search in property grid
    - More user control in DXF export
    - i-model publishing
    - Bentley DTM support in TRex
    - New Compute Center
    - Enhanced element type support including pond and pumps
    - Enhanced gutter support
    - Support for Cross Section Catalog referencing
    - HEC-22 3rd Edition headloss
    - Improved Model Management
    - "Depressed Gutter?" property in the gutter element

    Please see this link for a video presentation on What’s New with SewerGEMS SELECTseries 3 and other Storm and Sanitary products.

    Support for Newer Platforms and Operating Systems

    StormCAD now supports the following:

    • Windows 8 (32- and 64-bit)unified
    • AutoCAD 2012 and 2013 (32-bit and 64-bit)
    • MicroStation V8i SELECTseries 3 (build 08.11.09.xx) and SELECTseries 2 (build 08.11.07.xx)
    • ArcGIS 10 and 10.1
    • ProjectWise V8i (build 08.11.09.xx and 08.11.07.xx)

    In addition, StormCAD now offers support for interoperability with the latest releases of InRoads, GeoPAK, LandXML, and Bentley MX Drainage

    Note that in order to integate with 64-bit versions of AutoCAD 2012 and 2013, StormCAD will need to be installed as a 64-bit application as well. As with the previous release of SewerGEMS this requires the either the 64-bit version of Microsoft Office be installed or no instance of Microsoft Office installed. MicroStation and ArcGIS are strictly 32-bit applications and do not require this for the integration to complete.

    Unified Schema and One Common Data File Format

    StormCAD now uses the file extension “.stsw” for new projects, and will automatically convert existing projects saved in earlier versions of StormCAD that had used the old file extension (.stc).

    In addition to StormCAD projects, users now have the ability to open other Bentley storm and sewer (CivilStom, SewerCAD, SewerGEMS) projects within StormCAD and save them in one common data file format.

     

    Keywork Search in Property Grid

    Users can find the property they want quickly in the property grid using keyword search. To use this function, open the property grid for any element, by either double-clicking on the element or going to View > Properties. The new Property Search field is above the list of element properties. Simply start typing the word you are searching for and the property grid will dynamically filter to show any property field name that contains the phrase entered.

    Recent searches are stored in the drop down selection. The search term is maintained even when selecting a different element or element type. To clear the selection, click the Clear button beside the drop down.

    More user control in DXF export

    StormCAD now offers more control over layer/level assignment during DXF export. When you use the Export command, you first specify the drive, directory, and file name of the DXF file to be saved. Then the Export to DXF Layer Settings window opens, allowing you specify the names of the DXF layers on a per-element type basis.

    The Export to DXF Layer Settings dialog is divided into tabs for Link Layers, Node Layers, and Polygon Layers.

     

    Each tab contains a table that allows you to specify a prefix and suffix for the associated DXF layer. The Preview field displays how the label will appear.

    Note that specifying a prefix or suffix also creates new layers for each prefix/suffix. If no prefix or suffix is specified all links, nodes, and polygons will be exported to the same DXF layer.

    The Link Layers tab has additional controls: Entering a value in the Pipe Size Significant Digits field allows you to organize the pipe layer into multiple layers taking the pipe sizes into account using the Layer by Pipe Size checkbox.

    i-model publishing

    With the SELECTseries 3 release of StormCAD V8i, you can now publish an i-model. An i-model is an immutable container for rich multi-discipline information published from known sources in a known state at a known time. Basically it is a portable, read-only copy of a model file that can be viewed by users that do not have StormCAD. The topology as well as the attributes and results (for a particular timestep) can be viewed in MicroStation, ProjectWise Navigator, and Bentley View. Since Bentley View is free, i-models provide a way for anyone to easily view data and results for a StormCAD model file.

    Under File > Export, you will have a "Publish i-model" option, which requires the i-model publishing engine (downloadable from selectservices.bentley.com). The i-model publishing engine shows as a prerequisite on the download page for SewerGEMS, but is only necessary if you intend to publish i-models. If you have no need to publish i-models, you do not need to download and install this optional component.

    Bentley DTM support in TRex

    In addition to previously supported file formats, the TRex tool in StormCAD now supports the Bentley DTM file format. This is available through the Data Source Type pulldown.

     

    New Compute Center 

    Users can now perform all actions related to model runs through one common location using the Compute Center. This streamlines the process modeling process of changing frequently used calculation options properties, including creating new calculation options. These functions are still available in the Calculations Options properties though.

      

    The Compute Center is docked to the lower left of the drawing pane by default, and is accessible through the Analysis pulldown.

    Enhanced element type support including ponds and pumps

    Elements that were previously unavailable from the other Storm and Sewer programs are now supported for the GVF Rational solver. Pumps are now supported as ideal flow pumps, meaning that flow in will equal flow out and the pump curve is not used in the calculations. Ponds with no control structure will be treated as a junction where flow in will equal flow out. For ponds with control structures the flow out of the pond is determined by the specified pond initial elevation and the hydraulic calculations for the outlet control structure determine the pond outflow. Once the pond outflow is determined it becomes a fixed flow (system additional flow) and all other fixed and rational flow elements are terminated at the pond outlet. The new fixed outlet flow is carried on downstream.     

    All the other storm and sewer numerical solvers, including StormCAD, have the ability to handle all element types, gravity as well as pressure. Note that some limitations apply to certain elements in certain solvers.

    Enhanced gutter support

    StormCAD now supports new gutter shapes (v-shaped and parabolic gutters) in addition to the gutter shapes previously supported.

    Also a Gutter Catalog is now available, accessible through the Components pulldown, or in the gutter property field “Catalog Gutter.” This allows for commonly used gutter types to be stored in the Engineering Library, and made available for gutters that may be in other models, similar to the Conduit Catalog. When a gutter from the Gutter Catalog is used, the properties in the catalog entry are used in the model calculations.

    Support for Cross Section Catalog referencing

    A Cross Section Catalog is now available for use in setting up channel data through the Cross Section property grid. The Conduit Catalog is used for this. Users can assign a catalog cross-section by picking a trapezoidal channel or irregular channel type in the Conduit Catalog. The Conduit Catalog is accessible through either Components pulldown or by clicking the <Edit Conduit Catalog>  option in the pull down area of the "Catalog Cross Section.” property. This property is only available if the "Cross Section Type" property is set to 'Catalog Cross Section'

    HEC-22 3rd Edition headloss

    Node headloss calculations in accordance with HEC-22 3rd Edition are now available in SewerGEMS. To use the third edition calculations, select it from the "Headloss Method" type field in the Physical(Structure Losses) area of the element properties. Note that the second edition standard is still available.

    Improved Model Management

    StormCAD offers more flexibility to users in connecting different element types for more ease in laying out a model and morphing of one element type into another.

    User notifications have been improved to allow so that modeling errors can be found more quickly and efficiently

    Also, StormCAD offers a new category of common graph properties for each element type to enable the user to quickly find and use the most commonly graphed properties.

    Flextable field display now has handling for multiple solvers, as not all fields are used for all solvers. Users can now choose to display fields specific to the active numerical solver (default setting) or all fields available in the product.

    StormCAD now handles conflicts in controls better, with improvements to model validation and user notifications.

    StormCAD now allows users to generate profiles for virtual links and diversions.

    What is the difference between the "Depressed Gutter?" property in the gutter vs. catch basin elements?

    There is now a boolean property in the gutter element for "Depressed Gutter?". You might notice that this property is also present in the catch basin properties under the physical section too. When the property is set to "True" in either element the 'Gutter Cross Slope' and 'Gutter Width' fields are exposed.

    The difference between these is in gutter element itself these fields define the gutter shape up to the inlet. In the inlet element these fields define the gutter shape just on upstream side of the inlet opening where the spread is highest. The property is included in the inlet because it's possible the gutter changes slope or shape slighty right before the inlet.  

    See Also

    What's new in SewerCAD V8i SELECTseries 2?

    What's new in SewerGEMS V8i SELECTseries 3?

    Product TechNotes and FAQs

    Haestad Methods Product Tech Notes And FAQs

     

    External Links

    Water and Wastewater Forum

    Bentley Technical Support KnowledgeBase

    Bentley LEARN Server

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies