Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenFlows | Hydraulics and Hydrology
  • Product Communities
  • More
OpenFlows | Hydraulics and Hydrology
OpenFlows | Hydraulics and Hydrology Wiki Setting the invert elevation for multiple conduits coming into one manhole
    • Sign in
    • OpenFlows | Hydraulics and Hydrology Wiki
    • +Bentley CivilStorm
    • +Bentley CulvertMaster
    • +Bentley FlowMaster
    • +Bentley HAMMER
    • +Bentley HEC-PACK
    • +Bentley OpenFlows FLOOD
    • +Bentley PondPack
    • +Bentley SewerCAD
    • +Bentley SewerGEMS
    • +Bentley StormCAD
    • +Bentley WaterCAD
    • +Bentley WaterGEMS
    • +Calculations
    • Consuming ContextCapture production files within your hydraulic model
    • Convergence NOT achieved Message when computing StormCAD or SewerCAD model
    • Converting Junctions or Hydrants to Isolation Valves
    • Displaying Shapefile Labels (Text) As a Background
    • Error "System.TypeInitializationException"
    • Error 32768 when opening model while integrated with ProjectWise
    • Error installing patch set: "Cannot create output file: ..."
    • Error when opening PondPack: "Object reference not set to an instance of an object" or "Application has generated an exception that could not be handled."
    • Error when saving or validating: System.AccessViolationException: Attempted to read or write protected memory.
    • File Open Dialog does not appear
    • Flextable Report of Multiple Element Types
    • +General
    • Get to know WaterGEMS, WaterCAD and HAMMER CONNECT Edition
    • +Help and Documentation
    • How do I import/export multiple point pump curve pump definitions into a model using ModelBuilder?
    • How do you save backup files, so they save at different times and multiple levels?
    • How does the intermediate geodatabase (.mdb) file function in WaterGEMS for ArcMap?
    • How to Delete Engineering Libraries
    • How to Find Total Pipe Water Volume
    • How to receive alerts on new version availability
    • How to register DAO360.dll or a dll file?
    • How to search using wild cards on a sqlite type of database
    • How to See Hebrew or Arabic text in a .DXF file that was exported from WaterGEMS/WaterCAD
    • Hydraulic grade discontinuity at steep pipes or across nodes (frontwater analysis)
    • I get a red user notification that says, "Inlet guttter mannings n should be greater than 0".
    • Importing .HLB library files from old product versions into format used in the V8 product versions
    • Importing External Data in Geographic Coordinate Systems
    • Importing storm data and other library information from older versions
    • In the AutoCAD platform, is there a way to change the shape of an element?
    • +Installation
    • +Integration
    • Interchange
    • Internal Software Error when trying to print network
    • +Layout and Data Input
    • +Licensing / Activation
    • Locating OpenFlows product error log file
    • Model backward / forward compatibility
    • Model can be opened and used by multiple users
    • Modelbuilder for WaterGEMs for ArcMap only creates one pipe
    • +Modeling
    • Modeling a closed loop system
    • Modeling a flow split (diversion) with the SewerCAD or StormCAD numerical solver
    • Modeling turbine load acceptance plus load rejection
    • Multiple CN numbers for a catchment and multiple catchments with a single outlet node
    • Multiplying inflow loads by a certain factor
    • Network Navigator Trace Upstream/Downstream does not return any elements
    • No Pressure Pipe Flextable in CivilStorm
    • Not seeing changes to demands or status after exporting Darwin Designer run
    • +OpenFlows Product TechNotes And FAQs
    • +OpenFlows SewerOPS TechNotes and FAQs
    • OpenFlows software numerical solver theory
    • +OpenFlows WaterOPS TechNotes and FAQs
    • +Other
    • +Output and Reporting
    • Percent Connected Impervious Areas and Percent Unconnected Impervious Areas
    • Performing a hydrosanitary design in WaterGEMS or WaterCAD
    • +PondPack
    • PondPack user notification: "The composite outlet structure is either not selected or deleted."
    • PondPack: How to perform a critical duration analysis?
    • Presentation of elements in right-click-menu reports
    • Pressure pipe vs. conduit between pump and wetwell
    • Print Preview > Fit to Page shows blank page
    • Properties not working when using MicroStation integration with ProjectWise
    • Properties, Flextables, user notifications, or other dialog is missing or will not open in standalone
    • Properties, user notifications, or other tool managers not showing up in Integrated version of AutoCAD
    • Receiving error message when trying to save project
    • Reusing Pump Definitions (Import / Export)
    • Reversing orientation of Pipes and Conduits in Bulk
    • Saving a hydraulic model when using the AutoCAD platform (i.e. integrated)
    • Setting the invert elevation for multiple conduits coming into one manhole
    • +SewerGEMS
    • Simple Controls vs. Logical Controls
    • Sorting and relabeling a flextable based on upstream-downstream order
    • Source of the default Specific Speed for pumps and turbines
    • Step by step procedure for finding the curb length needed to capture 100% of gutter flow in a curb inlet with a continuously depressed gutter with no clogging
    • System.Reflection.TargetInvocationException crash when trying to open the application
    • Test Wiki Page - A1
    • Text, cells/blocks and line styles do not display correctly in a DXF background layer
    • The flow annotation (label) in my WaterGEMS for ArcMap isn't reflecting the value displayed in my Geotable or Flextable
    • The total area in the CN/Area Collection does not equal the total catchment area
    • Time tolerance setting in SCADAConnect Simulator
    • Troubleshooting ArcMap / ArcGIS Integration (menus or toolbars not showing)
    • Turbine Efficiency
    • Understanding Flow (Additional Subsurface) and Flow (Additional Carryover)
    • Unit of pressure measure "bar" for German language settings
    • Upcoming training and release dates for OpenFlows products
    • User notification "Downstream TW out of range..."
    • User notification "Pump exceeds the maximum operating point specified for the pump curve"
    • User Notification - The captured surface flow at this node does not connect a valid subsurface network. The flow is lost from the system.
    • User Notification: "Number out of range. Looking for value that is less than lowest table value."
    • User Notification: "There is an error in the data for this pipe. The associated data is incorrect"
    • User Notification: Cross section maximum elevation is above the maximum headwater elevation
    • User notifications about missing or inactive downstream pipes generated, but they are present and active in the model
    • User Notifications: "Pump On elevation is not in the range of upstream ...." and "Off elevation of pump is lower than ..."
    • Using batch pipe split to fix nodes that overlay a pipe instead of connecting to it
    • Using PondMaker with different tailwater for each return event
    • Valve "Status (Initial)" Definitions
    • Velocity Calculations and the Average Velocity Methods in SewerCAD and StormCAD
    • Viewing graph data for multiple scenarios
    • Water age results in a pipe are different from the age in the downstream junction
    • Water Loss Management
    • Water quality Analysis during transient events
    • WaterGems Tips
    • What are the limitations of importing/exporting EPANET files?
    • What is the dotted line that is associated with the isolation valves? Can I turn them off?
    • What's new in WaterCAD, WaterGEMS and HAMMER V8i SELECTseries 6 with CONNECT Integration?
    • What's New in WaterOPS CONNECT Edition 2.3 (Build 10.02.03.06)
    • When I do a copy/paste of zones they do not show up in the flex table.
    • When the user changes the fluid, why doesn't the calculated pump head change?
    • Xbox game bar appears when using HAMMER

    You are currently reviewing an older revision of this page.

    • History View current version

    Setting the invert elevation for multiple conduits coming into one manhole

       
      Applies To 
       
      Product(s): Bentley SewerCAD, SewerGEMS, CivilStorm, StormCAD
      Version(s): 08.11.XX.XX
      Environment:  N/A
      Area:  Layout and Data Input
      Subarea: 
      Original Author: Mark Pachlhofer, Bentley Technical Support Group
       

    Background

    This will explain how to define the invert elevation for multiple conduits coming into one manhole, since the manhole only has one invert field. The 'Elevation (Invert in 1)" , "Elevation (Invert in 2)", "Elevation (Invert in 3)", etc... fields only apply to the GVF-Convex (SewerCAD) solver and the GVF-Rational (StormCAD) solver. They will not display information for the Implicit (SewerGEMS, CivilStorm) solver or the SWMM solver. 

    Steps to Accomplish

    "Set the invert start?" or "Set the invert stop?" field equal to 'False'

    The inverts of conduits are set in the properties of your conduits

    1. Double click on the first upstream conduit to open the properties of it.

    2. Look for the property called "Set invert to Stop?" and set it to 'False'. Confirm that the stop node is correctly set to the downstream node in question.

    3. Once done have the option to enter the value for the 'Invert(Stop)' field.

    4. Repeat steps 1-3 for the other incoming conduits.

    *If the "Set invert to Stop?" is set to 'True' the 'Elevation (Invert in 1)" , "Elevation (Invert in 2)", "Elevation (Invert in 3)", etc...  field will still populate the values from the other conduits, but you will not be able to set the values. Therefore, the values are automatically populated from the elevation invert fields of the upstream/downstream manhole. For example, in the screen shot below the invert level of the manhole in the blue box would populate the 'Elevation (Invert in 1)"  field automatically, instead of letting the modeler enter a value.

     

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • User Management
    • Licensing Manager
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2019 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies