You are currently reviewing an older revision of this page.
Getting an error message like below when using/testing the Citect datasource:---------------------------SCADAConnect Message---------------------------Citect ctAPI dlls are missing. Please copy the required ctAPI dlls into the WaterGEMS installation folder.---------------------------OK ---------------------------
OR
---------------------------Bentley WaterGEMS V8i (SELECTseries 5)---------------------------Citect API dlls are missing. Please copy the required ctAPI dlls into the application installation folder.---------------------------OK ---------------------------
There are some dll (assembly) files needed to use the Citect DataSouce in SCADAConnect and they need to be at the same location where WaterGEMS/WaterCAD/HAMMER is running.
Please make sure you have following dll files in the directory where the product is running (generally C:\Program Files (x86)\Bentley\WaterGEMS or WaterCAD or HAMMER\).Version 7 (or 6) of Citect needs:CiDebugHelp.dllCtApi.dllCtEng32.dllCtg32.dllCtRes32.DLLCtUtil32.dllCt_ipc.dllThe above listed files can be obtained from the computer where Citect is installed. Pleae copy/ these files to the directory from where software (WaterGEMS, WaterCAD, HAMMER) is running.If you couldn't obtain the files listed above, please contact Technical Support Group.
http://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/could-not-establish-scada-connection-scadaconnect-citect.aspx