Getting an error message like below when using/testing the Citect datasource:---------------------------SCADAConnect Message---------------------------Citect ctAPI dlls are missing. Please copy the required ctAPI dlls into the WaterGEMS installation folder.---------------------------OK ---------------------------
OR
---------------------------Bentley WaterGEMS V8i (SELECTseries 5)---------------------------Citect API dlls are missing. Please copy the required ctAPI dlls into the application installation folder.---------------------------OK ---------------------------
There are some dll (assembly) files needed to use the Citect DataSouce in SCADAConnect and they need to be at the same location where WaterGEMS and WaterCAD are running.
Please make sure you have following dll files in the directory where the product is running (generally C:\Program Files (x86)\Bentley\WaterGEMS or WaterCAD or HAMMER\).Version 7 (or 6) of Citect needs:CiDebugHelp.dllCtApi.dllCtEng32.dllCtg32.dllCtRes32.DLLCtUtil32.dllCt_ipc.dllThe above listed files can be obtained from the computer where Citect is installed. Pleae copy/ these files to the directory from where software (WaterGEMS, WaterCAD, HAMMER) is running.If you couldn't obtain the files listed above, please contact Technical Support Group.
Could not establish SCADA connection SCADAConnect Citect