Mulitple CN numbers for a catchment and multiple catchments with a single outlet node

   
  Applies To 
   
  Product(s): Bentley CivilStorm, Bentley SewerGEMS, Bentley PondPack
  Version(s): 08.11.xx.xx
  Environment:  N/A
  Area:  Modeling
  Subarea: 
  Original Author: Scott Kampa, Bentley Technical Support Group
   

Problem Description

Is it possible to have more than one CN value for a catchment, or to have more than one catchment go to a single outlet node?

Steps to Resolve

If you have a catchment area with different land and drainage types, you will see the rainfall runoff act differently. Pavement will see less infiltration than grassy areas, etc. To make sure you have the most accurate results, you may want to split these areas up so that the runoff is correctly applied to an outflow node. There are a couple of ways to do this.

First, you can model the different land types with different catchments. Each catchment area will have a different CN value. If these catchment areas drain to the same outflow node, it is possible to assign the same outflow node to multiple catchments.

The alternative to this is to model the different land types in the same catchment area, but use a composite CN value. To set this up, open the catchment properties and find the attribute "CN Area Type". Set this field to "Composite CN".

A new attribute will become available: CN Area Collection. Click the ellipsis (...) button in this field to open the CN Area Collection dialog.

In this dialog, you can enter a description, the CN value, and the area for each land type in the catchment. The program will calculate composite CN value based on this input.

  • Created by Bentley Colleague
  • When: Tue, Sep 17 2013 4:26 PM
  • Last revision by Bentley Colleague
  • When: Fri, Mar 18 2016 11:08 AM
  • Revisions: 2