Multiple Demand Adjustments
Scott Kampa
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Editioin, V8i Area: Calculations Can multiple adjustments (via the Demand Adjustment calculation option) be applied to the demand at a junction? Yes. All adjustments…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Calculated demand does not match entered demand
Jesse Dringoli
Product(s): WaterCAD, WaterGEMS Version(s): V8i, CONNECT Edition Area: Output and Reporting Problem After computing a model, the calculated demand is different than the entered fixed demand. For example for a steady state…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki