• dgn and 4 tiff images wont stack/align so I can draw in roads using tiff images??

    I have a .dwg file that was converted to a .dgn file. I also have 4 .tif images. When I open the .dgn file the data shows up but when I reference in the 4 .tif images they are shot way up in the middle of no where. I have choose a coordinate system to…
  • Why can't I enter an angle in bearing form as my Active Angle?

    Applies To Product(s): MicroStation Version(s): V8i (SS3) Environment: N\A Area: Settings Subarea: N\A Original Author: Bentley Technical Support Group …
  • How to check for overlapping elements

    Product: MicroStation Version: V8, XM, V8i, CONNECT Environment: N\A Area: Selection Subarea: General Problem How to check for overlapping elements in a design file so they can either be moved…
  • Unable to paste elements from one design file to another as user only has option to paste picture

    Product: MicroStation Version: V8, XM, V8i, CONNECT Environment: N\A Area: OLE Subarea: N\A Problem Unable to paste elements from one design file to another user only has option to paste picture…
  • Re: "Maximum Element Size" message when Modify vertex

    What 8-digit version of MicroStation are you using? What type of file are you working on? If the answer to either of those is pre-V8, that is expected behavior, as 101 vertices was the maximum number allowed in those releases (because that was what the…
  • Key-in: Working Units > Accuracy

    Is there a key-in I can pair with the one below for setting the accuracy under the Working units? I was hoping to set up a batch to change this. -SET UNITS [Master] [Sub]
  • Panning in 2 views

    Yesterday I watched a webinar given by GeoCue Corp. using LIDAR data in Microstation V8 SS?. They were showing a plan view and an elevation view of some power lines and then the presenter started a 'pan' sequence in plan view(2) and the elevation…
  • Packager. Reference file settings. Configuration options.

    Looking for some ideas on a referencing issue when files are moved. We received 450+ .dgn files from another consultant. This other consultant created 4 packages for the same project. 1 package for Roadway Construction, 1 package for Detour Plan…
  • How to speed up the process of file opening?

    (posted on behalf of user) Using MicroStation V8 2004 (08.05.02.35) V8 DGN-files of large size (aprox. 32 MB) are stored in their central office. When accessing the files from their other office it takes around 5 minutes to open one file. There…